Lite-Puter DP-A04 User Manual

4 channel current sensor

Advertisement

Quick Links

ISO 9001 CERTIFIED
www.liteputer.com.tw
DP-A04
4 Channel Current Sensor
【User Manual】
Lite-Puter Enterprise Co., Ltd.
Website:www.liteputer.com.tw
E-mail:sales@liteputer.com.tw
Lite-Puter
DPA04[EUM-B]

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DP-A04 and is the answer not in the manual?

Questions and answers

Summary of Contents for Lite-Puter DP-A04

  • Page 1 ISO 9001 CERTIFIED www.liteputer.com.tw DP-A04 4 Channel Current Sensor 【User Manual】 Lite-Puter Enterprise Co., Ltd. Website:www.liteputer.com.tw E-mail:sales@liteputer.com.tw Lite-Puter DPA04[EUM-B]...
  • Page 2: Table Of Contents

    Chapter One Introduction.......................1 1-1 Feature .........................1 1-2 Specification ........................1 1-3 Function ........................2 1-4 Dimension........................3 1-5 Wiring Diagram ......................3 Chapter Two Function ......................4 2-1 ID Setting........................4 2-2 Zone Setting.........................4 2-3 Display Current Value ....................4 2-4 Read Current value ......................5 Lite-Puter DPA04[EUM-B]...
  • Page 3: Chapter One Introduction

    ■ Can read current value. 1-2 Specification ■ Power Supply: DC-12V (200mA) ■ Protocol: RS-485 ■ Signal Input Connector :4PIN green terminal ■ Sensor Signal Output Connector: 4 groups of 2PIN green terminal ■ Dimension: 132*76*35mm(W*H*D) ■ Weight: 220g Lite-Puter DPA04[EUM-B]...
  • Page 4: Function

    ISO 9001 CERTIFIED www.liteputer.com.tw 1-3 Function Front Flank Up button LED display Down button EDX port FUNC button 4 PIN green terminal(EDX) DMX button 4 groups of 2 PIN green terminal(sensor signal output) Lite-Puter DPA04[EUM-B]...
  • Page 5: Dimension

    ISO 9001 CERTIFIED www.liteputer.com.tw 1-4 Dimension Dimension:132*76*35mm(W*H*D) 1-5 Wiring Diagram Lite-Puter DPA04[EUM-B]...
  • Page 6: Chapter Two Function

    No. , which has two parts: the former two digits is Zone; the latter two is start channel address. For example, in the first group there are 16 channels and 4 DP-A04 , the Zone setting of each of the 4 devices will be 01-01、01-05、01-09、01-13.
  • Page 7: Read Current Value

    ISO 9001 CERTIFIED www.liteputer.com.tw 2-4 Read Current value This device use EDX protocol. Users can read the current value of each channel through DP-A04’s software on PC as showed below, Lite-Puter DPA04[EUM-B]...