Seto EP4000 Instructions For Use Manual

E-power mobility pack

Advertisement

Available languages

Available languages

Quick Links

Professional Lighting Solutions
GEBRAUCHSANLEITUNG
INSTRUCTIONS FOR USE
SETO E-POWER MOBILITY PACK
SETOLITE Lichttechnik GmbH
Bockhackerstr. 13 - 42499 Hückeswagen, Germany
 +49 2192 93624-0 -  +49 2192 93624-25
info@setolite.de - www.setolite.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EP4000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Seto EP4000

  • Page 1 Professional Lighting Solutions GEBRAUCHSANLEITUNG INSTRUCTIONS FOR USE SETO E-POWER MOBILITY PACK SETOLITE Lichttechnik GmbH Bockhackerstr. 13 - 42499 Hückeswagen, Germany  +49 2192 93624-0 -  +49 2192 93624-25 info@setolite.de - www.setolite.com...
  • Page 2 Entsorgung Rücknahme von Altgeräten Technische Daten Gültigkeit der Gebrauchsanleitung Diese Gebrauchsanleitung ist gültig für Mobility Packs der Serie SETO E-POWER MOBILITY PACK. Typenbezeichnung und Artikelnummer entnehmen Sie bitte dem Typenschild. WICHTIG VOR GEBRAUCH SORGFÄLTIG LESEN UND AUFBEWAHREN FÜR SPÄTERES NACHSCHLAGEN •...
  • Page 3: Gewährleistung

    Normen, die übertragenen Arbeiten beurteilen und mögliche Gefahren erkennen kann. Garantie reparaturen werden nur durch den Hersteller ausgeführt. Anwendungsbereich Die multifunktionalen, tragbaren SETO E-POWER MOBILITY PACKs sind in vielen Bereichen einsetzbar, an denen eine reguläre Stromversorgung (Innen- wie Außenbereich) nicht möglich ist, aber eine flexible Spannungsversorgung benötigt wird.
  • Page 4 Bedienelemente Ausführung EP1000 (A) Multifunktionsdisplay (B) Modus-Auswahl-Schalter (C) DC-5 V-Ausgang (D) Kühllüfter (E) Ladeeingang (F) Lichtschalter (G) Netzschalter (EIN / AUS) (H) LED-Licht (I) AC-Ausgang (J) Buchse und Diagnosestecker (nur für Servicezwecke) Ausführung EP2000 (A) Multifunktionsdisplay (B) Modus-Auswahl-Schalter (C) AC-Ausgang (D) Buchse und Diagnosestecker (nur für Servicezwecke) (E) Lichtschalter...
  • Page 5: Vor Inbetriebnahme

    Entladen der Batterie zu verhindern und das Mobility Pack zu schützen. HINWEIS! • Die SETO E-POWER MOBILITY PACKs sollten immer unter trockenen und kühlen Bedingungen betrieben werden. • Nicht in Wasser oder andere flüssige Substanzen tauchen. • Stellen Sie sicher, dass die Kühllüfter frei sind, um eine gute Wärmeableitung zu gewährleisten.
  • Page 6: Reinigung Und Pflege

    Verwenden Sie zum Entfernen von Schmutz, Staub, Öl und Fett usw. ein weiches, trockenes und fusselfreies Tuch. Wartung und Instandsetzung Das SETO E-POWER MOBILITY PACK wurde als wartungsfrei konzipiert. Es sind daher keine Wartungsarbeiten notwendig. Das Produkt ist reparaturfähig. Einzelne Komponenten können im Bedarfsfall durch eine Fachkraft ausgetauscht bzw.
  • Page 7: Technische Daten

    Technische Daten SETO E-POWER MOBILITY PACK EP1000 EP2000 Elektrische Daten Ausgang Wechselstrom 4,1 A 7,3 A Ausgang Wechselspannung 230 V Ausgang Leistung 800 W 1.400 W Wellenform Sinusform DC 5 V / 2 A Ausgang DC 5 V / 2 A DC 12 V / 3 A Überladung, Überlast, Entladung, Übertemperatur,...
  • Page 8: Table Of Contents

    Return of old equipment Technical data Validity of instructions for use These instructions for use are valid for mobility packs of the series SETO E-POWER MOBILITY PACK. Please refer to the rating plate for the type designation and article numbe IMPORTANT READ CAREFULLY BEFORE USE AND KEEP FOR LATER REFERENCE •...
  • Page 9: Warranty

    Field of application The multifunctional, portable SETO E-POWER MOBILITY PACKs can be used in many areas where a regular power supply (indoors as well as outdoors) is not possible but a flexible power supply is needed.
  • Page 10: Controls

    Controls Version EP1000 (A) Multifunction display (B) Mode selection switch (C) DC 5 V output (D) Cooling fans (E) Charging input (F) Light switch (G) Mains switch (ON / OFF) (H) LED light (I) AC output (J) Socket and diagnostic connector (for service purposes only) Version EP2000 (A) Multifunction display...
  • Page 11: Before Initial Operation

    INFORMATION! • The SETO E-POWER MOBILITY PACKs should always be operated under dry and cool conditions. • Do not immerse in water or other liquid substances. • Make sure that the cooling fans are free to ensure good heat dissipation.
  • Page 12: Cleaning And Care

    To remove dirt, dust, oil and grease, etc., use a soft, dry, lint-free cloth. Maintenance and repair The SETO E-POWER MOBILITY PACK was designed to be maintenance-free. Therefore no maintenance work is necessary. The product is repairable. If necessary, individual components can be replaced or repaired by a specialist.
  • Page 13: Technical Data

    Technical data SETO E-POWER MOBILITY PACK Type EP1000 EP2000 Electrical data Output AC 4.1 A 7.3 A Output AC voltage 230 V Output power 800 W 1,400 W Wave form Sinusoidal shape DC 5 V / 2 A Output DC 5 V / 2 A...
  • Page 14: Notizen / Notes

    Notizen / Notes...
  • Page 15 Notizen / Notes...
  • Page 16 © SETOLITE Lichttechnik GmbH Alle Rechte, einschließlich Übersetzung behalten wir uns vor. Die vollständige oder teilweise Vervielfältigung ist nur mit schriftlicher Genehmigung des Herausgebers zulässig. Die Angaben in diesem Dokument entsprechen dem technischen Stand bei Drucklegung, Änderungen in Technik und Ausstattung, sowie Irrtümer und Druckfehler vorbehalten. We reserve all rights, including translation.

This manual is also suitable for:

Ep1000Ep2000142800104014280010101428001020

Table of Contents