TECOM MMK Operation Manual

Smart monitor system

Advertisement

Quick Links

Smart Monitor System
MMK
Operation Manual
Copyright © 2017, All Rights Reserved.
Ver: R02 D/C: 107-0823

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MMK and is the answer not in the manual?

Questions and answers

Summary of Contents for TECOM MMK

  • Page 1 Smart Monitor System Operation Manual Copyright © 2017, All Rights Reserved. Ver: R02 D/C: 107-0823...
  • Page 2 TECOM Smart Monitor System Operation Manual Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
  • Page 3 TECOM Smart Monitor System Operation Manual The device must be installed at least 1 meter from radio frequency equipment, such as TVs, radios, hi-fi or video equipment (which radiate electromagnetic fields). Do not attempt to upgrade device in an unstable power environment. This could cause unexpected issues.
  • Page 4: Table Of Contents

    7.1 The wireless AP mode configuration (WiFi mode setup) ......33 7.2 WiFi mode setting ....................38 8. Hardware Settings ......................42 The setting instructions of Teco inverter and Tecom AG-300 Plus Gateway ....44 The App Software Operation ..................... 46 Page...
  • Page 5: Introduction

    TT-300 x 1 TT-300 x 1 TT-300 x 2 VB-200ST x 1 VB-200SC x 1 TS-200 x 2 TS-200 x 3 TS-200 x 4 VB-200ST x 1 This manual provides instructions for operating the MMK-Motor (MMK-2000) and MMK-Panel (MMK-2100). Page...
  • Page 6: Setting Up The Smart Monitor System

    TECOM Smart Monitor System Operation Manual Setting up the Smart Monitor System Wiring the Devices After unpacking the product package box, please connect the devices by following the connection figure as shown in below figure. A. The AG-300 Plus WAN port (blue) connects to the ADSL modem LAN port via the network cable.
  • Page 7: Rs-485 Wiring Method

    TECOM Smart Monitor System Operation Manual RS-485 wiring method (1) AG-300 Plus B/Z1 A/Y1 GND 12V B/Z2 A/Y2 1’st RS485 GND and 12V are common used by both RS485s 2’nd RS485 (2) TT-300 A. Connect TT-300 to AG-300 Plus by using CAT5e (or CAT6) cable.
  • Page 8 TECOM Smart Monitor System Operation Manual (3) VB-200ST/VB-200SC (RS485-) (RS485+) Twisted Pair Twisted Pair (4) PM-300 (RS485-) (RS485+) Twisted Pair Pin 22 (B) Pin 21 (A) Page...
  • Page 9: Pm-300 Pt/Ct Wiring Method

    TECOM Smart Monitor System Operation Manual PM-300 PT/CT wiring method Attention and warnings (1) It is prohibited to carry out wiring work during power is on line. (2) After the input power cut OFF, do not touch the circuit or change the wiring before the status P LED of PM-300 went off.
  • Page 10: Dimensions Of Devices

    TECOM Smart Monitor System Operation Manual Dimensions of devices (1) AG-300 Plus dimensions : 130mm (L) x 99mm (W) x 36 mm (H) (2) PM-300 dimension : 72mm (L) x 72mm(W) x 86mm (H) (3) TT-300 dimension : 59mm (L) x 36mm(W) x 16mm (H) (4) VB-200ST dimensions : 30.5mm (L) x 30.5mm (W) x 11.5mm (H)
  • Page 11: Pm-300 Views

    TECOM Smart Monitor System Operation Manual PM-300 Views Page...
  • Page 12: Tt-300 Views

    TECOM Smart Monitor System Operation Manual TT-300 Views Page...
  • Page 13: Vb-200St/Vb-200Sc Views

    TECOM Smart Monitor System Operation Manual VB-200ST/VB-200SC Views VB-200SC VB-200ST Vibration gauge installation position (recommended) Vibration measurement must observe the following rules according to ISO-10816 standard. 1. Close to the bearing 2. In direction either vertical or horizontal rather than 45-degrees or tilted direction 3.
  • Page 14 TECOM Smart Monitor System Operation Manual Vertical Axial Vertical Vertical Horizontal Vertical Horizontal Axial Axial Horizontal Axial Horizontal 3 Axials X/Y/Z Installation Location 3 Axials X/Y/Z Position 安裝位置圖 Vibration gauge 3-axis direction Direction identificat VB-200ST Direction identification Recognition in the...
  • Page 15: Installation Precautions

    TECOM Smart Monitor System Operation Manual Installation Precautions (1) VB-200SC is only suitable for installation with screw holes. If you want to add magnet, please use VB-200ST instead. (2) VB-200ST original magnet on the surface of the flatness requirements, can not be used in the cylindrical motor.
  • Page 16: Installation Reference

    TECOM Smart Monitor System Operation Manual Installation Reference 11-1 Vertical When the vibration gauge is installed in the vertical direction, it should be placed just above the rotating shaft. At this time, the Z-axis of the vibration gauge is the vertical direction.
  • Page 17 TECOM Smart Monitor System Operation Manual 11-2 Horizontal When the vibration gauge is installed in the horizontal direction, it should be placed on the level of the rotation axis, does not put too high, so as not to increase the vibration value. Put the higher position, the greater the value of the horizontal vibration.
  • Page 18 TECOM Smart Monitor System Operation Manual 11-3 Axial When the vibration gauge measurement value is the axial direction, it must be placed on the level of the rotation axis, do not put too high, so as not to increase the vibration value. Put the higher position, the greater the value of the horizontal vibration.
  • Page 19: Device Settings

    TECOM Smart Monitor System Operation Manual Device Settings Network Settings Step 1 - Make sure your PC/NB and the AG-300 Plus e-Gateway are in the same LAN (Recommended to use DHCP on your PC/NB) - Connect an Ethernet cable point-to-point between Notebook/PC and AG-300...
  • Page 20: Account Settings

    TECOM Smart Monitor System Operation Manual Step 2 (if the network is DHCP plug and play, you can omit this step) - In the left main menu click to use the【Settings】→【WAN Settings】. - Please select【STATIC (fixed IP)】in the WAN Connection Type Pull-down menu.
  • Page 21 TECOM Smart Monitor System Operation Manual Click on the left main menu to use the 【Settings】→【Unit Pairing 】, and then click the【Add】button. Step 2 - Name: Please enter your name. - Account: 100 (account number 100-119 total 20 groups). Page...
  • Page 22: Electromechanical Equipment Configuration

    TECOM Smart Monitor System Operation Manual - Password: Please enter your personal password (recommended account number). - When the setting is completed, click the【Save】button below. - Please click the【Start Pairing】to complete the account settings. Electromechanical equipment configuration Step 1 - Click on the left main menu to use the【Settings】→【RS485】.
  • Page 23 TECOM Smart Monitor System Operation Manual Step 2 Motor configuration table - Name: Please define it yourself. - Work ID: Please enter the motor number. - Voltage: Please fill in the motor specifications. - Current: Please fill in the motor specifications.
  • Page 24: Tt-300 Settings

    TECOM Smart Monitor System Operation Manual (Emergency shutdowns function: When an emergency alarm occurs, the user controls the APP to make the AG300 through Digital Output signal to the alarm device shutdown). Digital Output please refers to Note for wiring.
  • Page 25 TECOM Smart Monitor System Operation Manual - To add TT-300, please click the【+】button. - Line: Select to use line 1 or line 2, (Please select line 2 for TT-300) - RS485 ID: Please fill in according to RS485 specification. - Name: TT-300...
  • Page 26: Vb200 Settings

    TECOM Smart Monitor System Operation Manual Temperature 1/2/3 - Name: NDE / DE / R / S / T - Limit: Temperature alarm value, please fill in the motor specifications. - Early Warning: Temperature warning value, please fill in according to the motor specifications.
  • Page 27 TECOM Smart Monitor System Operation Manual - To add VB200, please click the【+】button under VB200 Item. - Line: Select to use line 1 for VB-200 (Recommended). - RS485 ID: Please fill in according to RS485 specification. - Name: VB-200 or defined by user.
  • Page 28 TECOM Smart Monitor System Operation Manual Vibration X / Y / Z - Name: X / Y / Z Vibration - Limit: Vibration alarm value, please fill in the motor specifications. - Early Warning: Vibration warning value, please fill in according to the motor specifications.
  • Page 29 TECOM Smart Monitor System Operation Manual Modify VB-200 RS485 ID Please follow the following steps to modify the RS-485 ID of VB-200. 1. Select the modify button 2. Modify VB-200's RS485 ID and press 【Save】 button Page...
  • Page 30: Elecmeter (Pm-300) Settings

    TECOM Smart Monitor System Operation Manual ElecMeter (PM-300) Settings - To add ElecMeter, please click the【+】button under ElecMeter Item. - To Select【PM300】in the Type field - Line: Select to use line 1 or line 2, (Please select line 2 for PM-300).
  • Page 31 TECOM Smart Monitor System Operation Manual - Down Limit: Under Voltage alarm value, please fill in the motor specifications. - Down Early: Under Voltage warning value, please fill in the motor specifications. - Low: Minimum voltage value, please fill in the specifications.
  • Page 32 TECOM Smart Monitor System Operation Manual - Time: Please fill in the required values. Power - Limit: Power alarm value, please fill in accordance with the motor specifications. - Early Warning: Power warning value; please fill in accordance with the motor specifications.
  • Page 33: Wireless Setup

    TECOM Smart Monitor System Operation Manual Wireless setup Designed for e-gateway AG-300 Plus hardware, the "wireless setup" page contains options of WiFi mode, "Basic", "Advanced", "Security", and "Station list". You may set WiFi mode into "Wireless AP mode" and "Wireless client mode".
  • Page 34 TECOM Smart Monitor System Operation Manual WiFi [Disable] page: see figure below: 7.1.2 Advanced wireless settings This option is aimed at setting up country/region and support channel with page as shown in figure below: Page...
  • Page 35 TECOM Smart Monitor System Operation Manual 7.1.3 Wireless security/encryption settings This option is aimed at setting up wireless security and encryption to prevent equipment access and monitoring without certification; available security modes are WPASKWPA2PSK and Disable with factory default set to the latter. See figure...
  • Page 36 TECOM Smart Monitor System Operation Manual Set up WPA algorithm, pass phrase, and key renewal interval; once set up and saved successfully users are required to input pass phrase set up here to connect to WiFi. Page...
  • Page 37 TECOM Smart Monitor System Operation Manual The client end is required to log in WiFi router of e-gateway AG-300 Plus2 with his/her smartphone: Page...
  • Page 38: 7.2 Wifi Mode Setting

    TECOM Smart Monitor System Operation Manual 7.1.4 Station list Users of this solution may monitor clients connected to AP. 7.2 WiFi mode setting Select STA mode and click [Apply] in the WiFi mode setting. Page...
  • Page 39 TECOM Smart Monitor System Operation Manual 7.2.1 Station profile Having a gateway as an ordinary client, this page displays information of APs saved in the gateway; you may add, delete, and edit information of desired AP; select an AP and click "Open", the gateway will then auto connect to the AP; even after gateway restart connection to pre-set AP will be established automatically.
  • Page 40 TECOM Smart Monitor System Operation Manual 7.2.2 Edit station profile In most cases, users may change parameters of "Name", "SSID", "BSSID" and "Security policy" and leave default value of the others intact in the station profile edit page. "Name": name of the profile "SSID": name of AP...
  • Page 41 TECOM Smart Monitor System Operation Manual 7.2.3 Station link status Link information after gateway connected to AP is shown here. 7.2.4 Scan near AP Page...
  • Page 42: Hardware Settings

    TECOM Smart Monitor System Operation Manual Scan gateway neighboring APs for information Click "Connect" to connect the AP; data of the latter are not saved (data lost after gateway restarted). Click "Rescan to scan" neighboring APs once again. Scanning may fail to identify all APs when there are many available nearby;...
  • Page 43 TECOM Smart Monitor System Operation Manual B. AG-300 Plus Pin Assignment (1) 1’st RS485 pin out : Pin 1 & 2 (2) 2’nd RS485 pin out : Pin 5 & 6 (3) DO pin out : Pin 7~9 (4) DI pin out : Pin 10~13...
  • Page 44: The Setting Instructions Of Teco Inverter And Tecom Ag-300 Plus Gateway

    Tecom AG-300 Plus Gateway This setting document is for the Teco inverter (hereinafter referred to as the inverter) and the Tecom AG-300 Plus Gateway (hereinafter referred to as the AG-300 Plus), in the hardware wiring and parameter settings for a brief description.
  • Page 45 TECOM Smart Monitor System Operation Manual RS485 Pin Assignment of Inverter RJ-45 and Connect to AG-300 Plus Data+ Data– Data+ RSV. RSV. Data– RS485 Pin Assignment of Inverter RJ-45 Parameter Setting Description: The following is the 510 series inverter parameter setting:...
  • Page 46: The App Software Operation

    Please look for PowerCloud in the APP store of IOS or in the Play store of Android to download and install the App in the mobile phone. The mobile phone must have the outbound network connection capability to use this App. Step 1 Please start TECOM Smart Monitor System APP. Step 2 Please click Sign In. Page...
  • Page 47 TECOM Smart Monitor System Operation Manual Step 3 - Account: 100 (Accounts between 100 ~ 119, total 20 sets). - Password: Please enter personal password. (Suggested to be identical to the account) - Server address: Please enter the IP address set in AG-300 Plus or the host ID code.
  • Page 48 TECOM Smart Monitor System Operation Manual Step 4 After logged in, please click the name of the motor to enter, to retrieve the information of that motor. TECOM Corp., Ltd No.23, R & D Rd. II, Hsinchu Science-based Industrial Park,...

This manual is also suitable for:

Mmk-2000Mmk-2100Mmk-2200Mmk-2210Mmk-2300

Table of Contents