  • Page 1 VLEG 5120A LFP Battery System User Manual V1.0 Master Instruments Pty Ltd | Official Distributor - Australia...
  • Page 2: Revision Table

    Revision Table Version Revised by Content Revision Date Rev1.0 First release 2024.09.02 Master Instruments Pty Ltd | Official Distributor - Australia...
  • Page 3: Table Of Contents

    5.1.1 Handling ..............................12 5.1.2 Transportation ............................12 5.1.3 Storage ..............................12 5.2 Battery Installation Requirement ........................13 5.2.1 Environment Requirement ........................13 5.2.2 Open-box Inspection ..........................13 5.2.3 Precautions before installation ........................14 Master Instruments Pty Ltd | Official Distributor - Australia...
  • Page 4 6.3.2 Capacity Test ............................20 7 Maintenance ................................21 7.1 Common Faults (Phenomenon) and Solutions ..................... 21 7.2 Daily Maintenance .............................. 22 8 Cautions and Warranty ..............................23 8.1 Cautions ................................23 8.2 Description of Warranty ............................23 Master Instruments Pty Ltd | Official Distributor - Australia...
  • Page 5: Overview

    The content of this manual will be constantly updated and revised, and update, revision or termination without prior notice. So please visit the our official website or obtain the latest product manual through your local distributors. Master Instruments Pty Ltd | Official Distributor - Australia...
  • Page 6: Product Description

    ABS shell which can be used 24/7. It has outstanding advantages of being waterproof, Bluetooth capabilities, heating features, impact resistance, good insulation performance, easy installation and maintenance-free. Battery module integrates intelligent BMS, which offer great advantages in terms of safety, cycle life, balancing and smart control. Master Instruments Pty Ltd | Official Distributor - Australia...
  • Page 7: Safety Instructions

    This side should be up Handle with care to avoid damage Keep dry Keep the battery away from kids Do not short circuit Do not reverse connection the positive and negative Master Instruments Pty Ltd | Official Distributor - Australia...
  • Page 8: Installation Tools

    3.3.3 Measuring Instrument In order to ensure that the electrical installation meets the requirements, please use the relevant electrical measuring equipment, such as multi-meter, power meters, etc. Master Instruments Pty Ltd | Official Distributor - Australia...
  • Page 9: Product Description

    And unique safety design (cell, structure, bracket, aerosol automatic fire extinguishing device) can greatly improve the safety performance of the battery. Table 4-1: VLEG 5120A battery specification Voltage Capacity Energy Width Depth Height Weight Type [Ah] [Wh] [mm] [mm] [mm] [kg] VLEG 5120A 51.2 5120 Master Instruments Pty Ltd | Official Distributor - Australia...
  • Page 10: Module Illustration And Front Panel Description

    4.2 Module Illustration and Front Panel Description Figure 4-1: VLEG 5120A Appearance drawing Master Instruments Pty Ltd | Official Distributor - Australia...
  • Page 11: Vleg 5120A Battery Front Panel Diagram

    Positive terminal M8 Screw RS485/CAN Communication port Switch Button Switch on/off the BMS BAT- Negative terminal M8 Screw Alarming indicates LED Operating indicates LED The state of charge 4 nos green LED Master Instruments Pty Ltd | Official Distributor - Australia...
  • Page 12: Led Indicator Status And Definition

    Flash Based on SOC indicator -current Short Short Flash: Normal flash OFF:0.5S/ON:0.5S Alarm Discharge End-off Voltage ALL OFF Go to sleep Over-Temp/Over-c urrent Protection Based on SOC indicator BMS Fault Master Instruments Pty Ltd | Official Distributor - Australia...
  • Page 13: Communication Port Diagram And Description

    CAN-L Pin 3 Pin 3 Pin 4 Pin 4 Pin 5 WARK Pin 5 WARK Pin 6 Vcc-12V Pin 6 Vcc-12V Pin 7 RS485-A Pin 7 RS485-A Pin8 RS485-B Pin8 RS485-B Master Instruments Pty Ltd | Official Distributor - Australia...
  • Page 14: Battery Installation

    50%~70%, store it in a dry, cool, non-corrosive gas, temperature 20-35 ℃, relative humidity 50 ± 15 %, in an environment without strong electromagnetic fields and direct sunlight, and make sure to charge once every 6 months to avoid irreversible capacity loss caused by long-term storage. Master Instruments Pty Ltd | Official Distributor - Australia...
  • Page 15: Battery Installation Requirement

    If the product is damaged, please contact the local distributor in time.Please open the box to check: whether the outer packaging is intact or damaged; whether the quantity and type of goods on the bill of materials are consistent with the description; whether the internal equipment is damaged. Master Instruments Pty Ltd | Official Distributor - Australia...
  • Page 16: Precautions Before Installation

    Use correct tools and appropriate method to avoid damage to the terminal, the recommended tightening torque is shown in the table. Table 5-3:Torque parameter sheet Scope of application Tightening torque value 8.5N*m 12.4N*m Master Instruments Pty Ltd | Official Distributor - Australia...
  • Page 17: Battery Installation

    ③.When multiple batteries are used in parallel, the rectangular metal strip can be used as a connecting plate, and an electric wrench is used to connect the batteries together, as shown in 5-2; Figure 5-2: Battery Installation Drawing Master Instruments Pty Ltd | Official Distributor - Australia...
  • Page 18 Figure 5-4: Battery Power Cable Connection Diagram Tips: 1) Ensure that the battery capacity are same before use. 2) VLEG 5120A battery can’t support series connection. Please pay attention to the wiring method. Master Instruments Pty Ltd | Official Distributor - Australia...
  • Page 19: Battery Use

    6.1 Bluetooth Setting ①. Download BatteryMonitorBL APP. Search for BatteryMonitor on the APP Store using phone, and download it, as shown in 6-1. Figure 6-1: APP Store search Master Instruments Pty Ltd | Official Distributor - Australia...
  • Page 20 If the batteries are connected in parallel, set battery ID1, 2, 3, …, ID16 according to the number of parallel connections. ID1 is the host and can be connected to the CAN display screen to display battery information. Master Instruments Pty Ltd | Official Distributor - Australia...
  • Page 21: Supplementary Power

    56V30A CC/CV Charging to 56V, cut-off current:5A ≤20℃ Once/9M 20℃~30℃ Once/6M 56V30A CC/CV Charging to 56V, cut-off current:5A Only for 51.2V module 30℃~40℃ Once/3M 56V30A CC/CV Charging to 56V, cut-off current:5A Master Instruments Pty Ltd | Official Distributor - Australia...
  • Page 22: Battery Discharge And End-Of-Life Judgment

    According to the standard capacity calibration method defined in the battery specification, charged and discharged the battery, and after three cycles, the last capacity is the actual capacity. If the test temperature and test conditions are different, the capacity value may fluctuate to a certain extent. Master Instruments Pty Ltd | Official Distributor - Australia...
  • Page 23: Maintenance

    Unbalance voltage with cell Examine/balance the cell capacity is insufficient Unable to charge and BMS or cell/temperature senor Maintenance or replacement discharge damaged Different SOC value of Normal phenomenon No operation batteries in parallel Master Instruments Pty Ltd | Official Distributor - Australia...
  • Page 24: Daily Maintenance

    SOH status of the battery is normal (using the upper computer software to Charge and discharge Once every 6 month read); it is recommended that the depth of discharge and maintenance charge/discharge power should not exceed 20% of the rated value Master Instruments Pty Ltd | Official Distributor - Australia...
  • Page 25: Cautions And Warranty

    Customers need to provide a valid purchase invoice or related product warranty information. If no valid proof can be provided, our company has the right to refuse to provide related services. Master Instruments Pty Ltd | Official Distributor - Australia...