M2I MGW-BH1000D Hardware Manual

M2I MGW-BH1000D Hardware Manual

Industrial iot gateway

Advertisement

Quick Links

Thank you for purchasing the industrial IoT GATEWAY series of M2I corporation.
Please read this manual carefully to know installing, wiring operating this equipment for safe use of this
product.
M2I Corporation
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do, 14055, Korea
Tel: +82-31-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
Industrial IoT GATEWAY Hardware Manual
M2I Corporation
Industrial IoT GATEWAY
MGW-BH1000D
Hardware Manual
1 / 17

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MGW-BH1000D and is the answer not in the manual?

Questions and answers

Summary of Contents for M2I MGW-BH1000D

  • Page 1 M2I Corporation Industrial IoT GATEWAY MGW-BH1000D Hardware Manual Thank you for purchasing the industrial IoT GATEWAY series of M2I corporation. Please read this manual carefully to know installing, wiring operating this equipment for safe use of this product. M2I Corporation...
  • Page 2: Table Of Contents

    3.4 Environment Specifications ............................6 3.5 Structure Specifications ..............................6 Chapter 4 Part Names and General Specifications..........................7 4.1 MGW-BH1000D ................................7 4.2 Product Dimension ................................. 7 4.3 Part Names and General Specifications ........................ 8 Chapter 5 External Device Interface ................................9 5.1 Serial Communication Specifications ........................
  • Page 3: Chapter 1 Safety Precautions

    Grounding should be the Class 3 grounding. The cable for grounding should be more than 2mm b. grounding point be closed to the products and make short the distance to the ground cable if possible. M2I Corporation 3 / 17 11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do, 14055, Korea Tel: +82-31-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr...
  • Page 4 ■ All field-wiring connections to this unit shall be from Limited Voltage / Limited Current, below 20 ~ 28Vdc isolated secondary source with an output fuse, or Class 2. M2I Corporation 4 / 17 11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do, 14055, Korea Tel: +82-31-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr...
  • Page 5: Chapter 2 Overview

    User Options (Sold separate) Cable fixing clamp VESA Mounting Bracket 2.3 Explanation of Model Name Base Unit Option Power -BH1000: Default D: DC M2I Corporation 5 / 17 11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do, 14055, Korea Tel: +82-31-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr...
  • Page 6: Chapter 3 General Specifications

    Protection Classification IP20 3.5 Structure Specifications Weight (Kg) 0.23 Cooling System Natural Air Circulation Installation Standard DIN Rail(35mm), VESA Case Material PC(Flameless) M2I Corporation 6 / 17 11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do, 14055, Korea Tel: +82-31-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr...
  • Page 7: Chapter 4 Part Names And General Specifications

    Industrial IoT GATEWAY Hardware Manual Chapter 4 Part Names and General Specifications 4.1 MGW-BH1000D 4.2 Product Dimension (mm) Model MGW-BH1000D 29.2 128.9 131.2 M2I Corporation 7 / 17 11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do, 14055, Korea Tel: +82-31-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr...
  • Page 8: Part Names And General Specifications

    USB HOST #2 USB A type USB Connecting Port, 5V/0.5A Output ETHERNET Port RJ45 2ch 10BASE-T/100BASE-TX, Auto-MDIX DIN RAIL DIN RAIL Holding Bracket (35mm) M2I Corporation 8 / 17 11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do, 14055, Korea Tel: +82-31-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr...
  • Page 9: Chapter 5 External Device Interface

    RS-422/485 Send Data (-) *1, *2) When need VCC for external equipment, connect 7 pin and 8 pin that output is 0.2A. M2I Corporation 9 / 17 11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do, 14055, Korea Tel: +82-31-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr...
  • Page 10: Ethernet Communication Specifications

    * In case of do not using HUB, do not use HUB, when it is connected directly, Cross Cable should be used. Ex) Cross Cable Wiring: In the above wiring diagram, TD+ and RD+ are changed, and TD- and RD- are exchanged. M2I Corporation 10 / 17 11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do, 14055, Korea Tel: +82-31-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr...
  • Page 11: Usb Specifications

    USB 2.0 Communication Method Interrupt/Bulk/Isochronous Transfer Speed 480Mb/s Supporting OS Windows 98SE/2000/XP/VISTA/7/10(32/64bit) 3M(recommended to use M2I's Option Cable), If purchased Cable Length separately for less than 1.5M. Connect Type MINI USB B, Female Connect Method Connect through USB OTG 5.4 HDMI Specifications...
  • Page 12: Chapter 6 Installation

    6.2 DIN RAIL Mounting and VESA bracket bonding This product has DIN Rail (width 35mm) Hook for mounting. 6.2.1 DIN RAIL M2I Corporation 12 / 17 11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do, 14055, Korea Tel: +82-31-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr...
  • Page 13: Chapter 7 Wiring

    Simple or Standard Wire ≥ 0.4N.m Bolt tightening force Conductor Length 65 ℃ or under Temperature rating of the field installed conductors M2I Corporation 13 / 17 11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do, 14055, Korea Tel: +82-31-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr...
  • Page 14: Ground Wiring

    (3) When you cannot do the exclusive ground, do common ground like figure B. (4) Use the cable more than 2mm . Put the point of the ground near product and shorten Ground line. M2I Corporation 14 / 17 11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do, 14055, Korea Tel: +82-31-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr...
  • Page 15: Installation Of Cable Clamp

    Is the input power in right range? (3) Related Items a. Make sure there is no foreign matter or contamination on the external contact area. M2I Corporation 15 / 17 11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do, 14055, Korea Tel: +82-31-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr...
  • Page 16: Problems With The Device

    (2) Only the authorized worker from M2I Corporation can check and repair problems related to malfunction of the machine. (3) If the problem cannot be solved at the installation site, the equipment can be collected and moved to M2I Corporation.
  • Page 17: Chapter 9 Products Label

    I Corporation 2024.10 www.m2i.co.kr - Please read related contents in this manual when you use M2I product, and operate the product staying safe with appropriate handling. - This manual should be stored in secured and appointed place so that it can be read in any needs.

Table of Contents