A. Open lock
1) Enter default manager code 1-2-3-4-5-6
B. Change reset code!
For safety reasons, the reset code must be changed immediately after
the lock is put into operation.
1) Enter 0-0-0-0-0-0
2) Enter default reset code 9-9-9-9-9-9, 1 beep
3) Enter new 6-digit reset code, 1 beep
4) Repetition of the new 6-digit reset code, 2 beeps
◘ 1 long beep means that the code is not allowed or the identical code was not
entered for repetition. Repeat steps 1 to 4.
◘ The reset code cannot open the lock.
C. Change code
5) Enter 0-0-0-0-0-0
6) Enter existing code, 1 beep
7) Enter new 6-digit code, 1 beep
8) Repetition of the new 6-digit code, 2 beeps
◘ 1 long beep means that the code is not allowed or the identical code was not
entered for repetition. Repeat steps 5 to 8.

Advertisement

loading
Need help?

Need help?

Do you have a question about the ScanLogic Basic FPC-1808-II VdS and is the answer not in the manual?

Questions and answers

Summary of Contents for EASTHOUSE ScanLogic Basic FPC-1808-II VdS

  • Page 1 ScanLogic Basic FPC-1808-II (VdS) To be used with locks EL-0601, EL-0701, EL-0901 OPERATING INSTRUCTIONS A. Open lock 1) Enter default manager code 1-2-3-4-5-6 B. Change reset code! For safety reasons, the reset code must be changed immediately after the lock is put into operation. 1) Enter 0-0-0-0-0-0 2) Enter default reset code 9-9-9-9-9-9, 1 beep 3) Enter new 6-digit reset code, 1 beep...
  • Page 2 ◘ For security reasons, we recommend changing the manager code immediately after the lock is put into operation. ◘ The default manager code 1-2-3-4-5-6 must be changed before other users can be added. Important! 1. Always carry out programming when the lock is open and the safe door is open.
  • Page 3 D. Adding the manager's fingerprints 1) Open with manager code/fingerprint 2) Press and hold "+", 1 beep 3) Place a fingerprint 4 times, 1 beep each time 4) 2 beeps confirm the addition of the fingerprint ◘ The manager can add up to 5 fingerprints. E.
  • Page 4 G. Delete all users (codes/fingerprints) 1) Open with manager code/fingerprint 2) Press and hold "3", 2 beeps ◘ All users have been deleted. ◘ The manager code/fingerprints did not change. H. Reset lock (deletes the user codes, all fingerprints and resets the manager code to default settings) 1) Enter reset code (The default reset code is 9-9-9-9-9-9, but we have already asked you to...
  • Page 5 I. Switch off beeper 1) Open with manager or user code/fingerprint 2) Press and hold "4", 1 beep J. Switch on beeper 1) Open with manager or user code/fingerprint 2) Press and hold "4", 2 beeps K. Security levels Security level 1 = code only (default setting) Security level 2 = fingerprint and code Change to security level 2(fingerprint and code)
  • Page 6 L. Penalty time after four invalid code entries Entering four (4) consecutive invalid codes will result in a penalty period of 5 minutes. 1) The unit beeps at 5-second intervals to indicate that it is in penalty time. 2) While the system is in penalty time, the buttons do not respond. 3) The penalty time is only interrupted by removing the battery, not shortened or deleted.
  • Page 7 Change battery There is a pull-out compartment for a 9V battery on the bottom of the input unit. We recommend to use Energizer™ or Duracell™ 9V ALKALINE batteries. To replace the battery, pull out the battery compartment first. Open the battery compartment latch. See Fig. 1. ...
  • Page 8 6 digits Only suitable for indoor use. Safe locks certified in accordance with EN1300 are not permitted to be opened by fingerprint only (without additional code entry). Doc. no.: FPC1808-121301-EN Version number: V1.00-EN.a : Date 13.01.2022 Easthouse Electronics Technology B.V.