Tzone TZ-TH602 User Manual

Tzone TZ-TH602 User Manual

Temperature humidity meter

Advertisement

TZ-TH602
---User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TZ-TH602 and is the answer not in the manual?

Questions and answers

Summary of Contents for Tzone TZ-TH602

  • Page 1 TZ-TH602 ---User Manual...
  • Page 2: Product Introduction

    1.Product Introduction TZ-TH602 is a professional instrument of our company for measuring ambient temperature, humidity, dew point temperature and wet bulb temperature. It is a high-precision, low-power digital temperature and humidity sensor, applicable to environments such as production workshops, factory warehouses, libraries, offices, laboratories, and family rooms.
  • Page 3: Product Specifications

    ◇ Low battery reminder ◇ Temperature and humidity measurement ◇ Automatic shutdown function ◇ Maximum and minimum measurement ◇ ℃/℉ temperature unit switching function ◇ Measurement of dew point temperature and wet bulb temperature 4.Product Specifications Sensor measures temperature Temperature:-20~60℃ range Humidity:0-100%RH Precision...
  • Page 4 Energy life About 50 hours (alkaline battery) Operating temperature 0~50℃ Operating humidity 10%~80%RH Storage temperature -10~60℃ Storage humidity 10%~75% Size 185mm×56mm×41mm Weight 100g 5.Structure introduction 1. Temperature and humidity sensor. 2. Liquid Crystal Display 3. Power on/off button. 4. Mode/unit switch key. 5.
  • Page 5 6.Display information introduction 7. operating instructions 1) Open the battery cover, install a 9V battery, and turn on the power. 2) Check whether the battery is sufficient. If the symbol is displayed on the screen, it indicates that the battery is insufficient and the battery should be replaced. 3) Place the meter where you need to measure, or fix it on a tripod.
  • Page 6 selected, the screen always displays the measured readings 5) Press the "℃/℉" key to cycle through the following modes: Temperature (℃ unit) → temperature (℉ unit) → dew point temperature (℃ unit) → dew point temperature (℉ unit) → wet bulb temperature (℃ unit) → wet bulb temperature (℉...
  • Page 7 corresponding to the point Dry bulb temperature. Wet bulb temperature is a means to calibrate the relative humidity of the air, and its meaning is that the air in a certain state, in contact with the humidity bulb of the wet bulb thermometer, undergoes adiabatic heat and moisture exchange, so that it reaches the temperature when it reaches the saturation state.

Table of Contents