1. SAFETY REGULATIONS AND INFORMATION

Read these operating instructions carefully before starting work on the
device. Observe the following warnings to prevent malfunctions or
danger to persons.
These operating instructions are to be regarded as part of the device.
The device is only to be sold or passed on together with the operating
instructions.
These operating instructions may be duplicated and distributed to inform
about potential dangers and their prevention.
1

1.1 Hazard levels for warnings

1
1
These operating instructions use the following hazard levels to indicate
1
potentially hazardous situations and important safety regulations:
1
2
2
2
2
2
2
2
3
4
4
5
5
5
5
5

1.2 Staff qualifications

6
The device may only be transported, unpacked, installed, operated,
6
maintained and otherwise used by suitably qualified, trained and
6
authorized technical staff.
6
Only authorized specialists are permitted to install the device, to carry
7
out a test run and to perform work on the electrical installation.
8
8

1.3 Basic safety rules

8
The safety hazards associated with the device must be assessed again
8
following installation in the final product.
The locally applicable industrial safety regulations are always to be
9
observed when working on the device.
9
Keep the workplace clean and tidy. Untidiness in the work area
9
increases the risk of accidents.
Note the following when working on the device:
; Do not perform any modifications, additions or conversions on the
device without the approval of ebm-papst.

1.4 Voltage

; Check the device's electrical equipment at regular intervals; see
Chapter 5.2 Safety inspection.
; Replace loose connections and defective cables immediately.
DANGER
Indicates an imminently hazardous situation which will result in
death or serious injury if the specified actions are not taken.
Compliance with the instructions is imperative.
WARNING
Indicates a potentially hazardous situation which can result in
death or serious injury if the specified actions are not taken.
Exercise extreme caution while working.
CAUTION
Indicates a potentially hazardous situation which can result in
minor or moderate injury or damage to property if the specified
actions are not taken.
NOTE
A potentially harmful situation can occur and, if not avoided, can
lead to property damage.
WARNING
Live terminals and connections even with device
switched off
Electric shock
→ Wait five minutes after disconnecting the voltage at all poles
before opening the device.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the K1G220-AB73-11 and is the answer not in the manual?

Questions and answers

Summary of Contents for ebm-papst K1G220-AB73-11

  • Page 1: Table Of Contents

    Note the following when working on the device: ; Do not perform any modifications, additions or conversions on the device without the approval of ebm-papst. 1.4 Voltage ; Check the device's electrical equipment at regular intervals; see Chapter 5.2 Safety inspection.
  • Page 2: Safety And Protective Features

    Operating instructions K1G220-AB73-11 CAUTION 1.8 Emissions If control voltage or a stored speed set value is applied, WARNING the motor will restart automatically, e.g. after a power Depending on the installation and operating conditions, failure. the sound pressure level may exceed 70 dB(A).
  • Page 3: Intended Use

    Operating instructions K1G220-AB73-11 2. INTENDED USE The device is exclusively designed as a built-in device for conveying air according to its technical data. Any other usage above and beyond this does not conform with the intended purpose and constitutes misuse of the device.
  • Page 4: Technical Data

    Operating instructions K1G220-AB73-11 3. TECHNICAL DATA 3.1 Product drawing All dimensions in mm. Cable PVC AWG20 with 2-pole connector housing Molex 39-01-2025, 2x socket Molex 39-00-0059 - (blue) + (red)
  • Page 5: Nominal Data

    With regard to cyclic speed loads, note that the rotating parts of the device are designed for a maximum of one million load Motor M1G074-BF cycles. If you have special questions, consult ebm-papst for support. Nominal voltage / VDC ; Use the device in accordance with its degree of protection.
  • Page 6: Connection And Startup

    Operating instructions K1G220-AB73-11 4. CONNECTION AND STARTUP 4.2.1 Requirements ; Check whether the information on the nameplate matches the 4.1 Mechanical connection connection data. ; Before connecting the device, make sure the power supply matches CAUTION the device voltage. Risk of cutting and crushing when removing device from packaging ;...
  • Page 7: Connection Diagram

    Operating instructions K1G220-AB73-11 4.4 Connection diagram Drawing preliminary! Conn. Designation Color Function/assignment Un +48 VDC Power supply 48 VDC, maximum ripple 3.5% blue Reference ground...
  • Page 8: Checking Connections

    Operating instructions K1G220-AB73-11 4.5 Checking connections 5. MAINTENANCE, MALFUNCTIONS, POSSIBLE CAUSES AND REMEDIES ; Ensure isolation from supply (all phases). ; Make sure a restart is impossible Do not perform any repairs on your device. Send the device to ebm- ;...