PF-1U-FA Operation and Maintenance Instructions Rev A Precision Filters, Inc. 240 Cherry Street Ithaca, NY 14850 www.pfinc.com pfinfo@pfinc.com...
Page 2
Revision Level History Rev Level Date Description 7/18/2012 Initial release 3/12/2013 Added Option 3, LEMO inputs with programmable single-ended or balanced differential inputs. PRECISION FILTERS, INC. REV A...
1 Hz to 204.6 kHz. The high performance PF-1U-FA has an upgraded wideband (500 kHz) low-noise amplifier with transducer DC suppress capabil- ity. Gain is programmable to x8,192. Figure 1.1 PF-1U-16FA Front Panel REV A PRECISION FILTERS, INC.
Page 8
Option I = BNC inputs with IEPE Current Source · PF-1UC-16FA-LP4FP-IZ 16-channel · Option 3 = LEMO inputs with programmable filter/amp with 4-pole low-pass filters single-ending or differential input configura- · PF-1UC-16FA-LP8FP-IZ 16-channel tions filter/amp with 8-pole low-pass filters PRECISION FILTERS, INC. REV A...
Ethernet Connector The front panel Ethernet connector is used to provide the control link to the host computer. Figure 1.2 Power Switch, TEST Connector, Warning Indicator and Ethernet Connector REV A PRECISION FILTERS, INC.
For alternative power sources, a DC mating con- nector is available. · Power Supply Mating Connector is a three pin Combo-D mating connector. PF pn A11328G1. Figure 1.3 Power Entry, Ground Binding Posts and MONITOR Output Connector PRECISION FILTERS, INC. REV A...
Max Temperature could result in personal injury or death. Do not Min Temperature proceed beyond a WARNING statement until the conditions are fully understood and met. Relative Humidity Less than 90%, non-condensing REV A PRECISION FILTERS, INC.
The system may be transported as a unit over a short distance if vibration and shock are held to an absolute minimum. Before transport, remove cables. The environmental conditions in Table 2.3 must be maintained. REV A PRECISION FILTERS, INC.
Always use the original packing materials to ship CAUTION system components. A new container can be pur- chased from Precision Filters. The environmental Only use the supplied 10-32 x 1/4 PF flat head conditions described in Table 2.3 must be main- Philips Screws when installing the mounting tained during shipment.
50.8 mm 2.00 in. 2.00 in. 50.8 mm 50.8 mm Non-Skid Foot Bottom Panel 2.00 in. 2.00 in. 50.8 mm 50.8 mm 2.00 in. 2.00 in. 50.8 mm 50.8 mm Figure 2.2 Non-Skid Feet Locations REV A PRECISION FILTERS, INC.
Ethernet connection between either a 28000 sys- through CH 7. tem or a PF-1U-FA system and the host com- puter. Precision Filters recommend the Direct LEMO Input Connectors - Option 3 Connection, the Network Switch Connection and the Dual Corporate Network Connection as the The PF-1U-16FA with Option 3 provides sixteen most reliable connection methods.
LEDs that can be used to verify proper sys- tem operation. PF-1UA or 28000 System PC Host Ethernet Computer Switch Additional PF-1UA or 28000 System Function Generator Straight Through Ethernet Cables Digital Multimeter Network Switch Connection Figure 2.5 Network Switch Connection Diagram REV A PRECISION FILTERS, INC.
PC Host 28000 Computer System Servers Additional Straight Through PF-1UA or Ethernet Cables 28000 System Phone Systems Function Generator Computers Digital Multimeter Corporate Network Connection (Not Recommended) Figure 2.6 Typical Corporate Network Connection Diagram (Not Recommended) PRECISION FILTERS, INC. REV A...
PF-1UA or Phone Additional 28000 System Systems Network Interface Function Generator Computers Straight Through Ethernet Cables Digital Multimeter Examples of High Dual Corporate Network Connection Ethernet Traffic (Recommended) Figure 2.7 Dual Corporate Network Connection Diagram (Recommended) REV A PRECISION FILTERS, INC.
The PF-1U-FA requires input power of 12-24 VDC, 75 W typical, applied at the rear panel POWER IN connector. Figure 2.9 PF-1U-ACPS2-120W Power Supply Markings Figure 2.8 Power Entry, Ground Binding Posts and MONITOR Output Connector PRECISION FILTERS, INC. REV A...
Step 1 Create a folder on the host computer to contain PF-1U-FA Utilities software. Copy the contents of the PF-1U-FA Utilities CD-ROM to the new folder. Figure 2.11 Connection to Programming Port Figure 2.10 PF-1U Utilities Folder REV A PRECISION FILTERS, INC.
Page 22
Step 10 In the Choose Flash Image window, enter the file location if known, or click on the “...” button to bowse for the location. Figure 2.13 Utilities Com Port Setup Figure 2.16 Choose Flash Image Panel PRECISION FILTERS, INC. REV A...
Step 13 When the flash image is fully loaded turn the system power off. Step 14 Remove the RS-232 cable from the Programming connector. Step 15 Install the bottom cover to the chassis. Step 16 Apply power to the system. REV A PRECISION FILTERS, INC.
Page 24
SITE PREP, INSTALLATION, MAINTENANCE PAGE 2-14 This page intentionally blank. PRECISION FILTERS, INC. REV A...