  • Page 1 User Manual V0.7 - 28.08.2023 Model:v4.0.1...
  • Page 2: Table Of Contents

    1 Product description 1.1 About 1.2 Product design 1.3 PLAATO Cloud 2 Getting started 2.1 Important Notes 2.2 How to get the best possible readings 2.3 Quick Installation 4 Installation 4.1 Placement on fermenter 4.2 Cleaning and sanitizing before installation 4.3 Alignment...
  • Page 3 8.1 Environment 8.2 Process 8.3 Technology 9 PLAATO Apps 9.1 The PLAATO Pro Apps 9.2 Customize the PLAATO Pro Apps 9.3 Create a Recipe 9.4 Create a Batch 9.5 Compare Batches 9.6 Create Batch Alerts 9.7 Rename your PLAATO Pro device 9.8 Export PLAATO Pro data...
  • Page 4: Product Description

    PLAATO-app, in addition to a range of other functionalities. Vibrating fork density meter The PLAATO Pro operates based on the principle of a vibrating fork density meter. This device utilizes the proportional relationship between the frequency of the vibrating tines and the density of the liquid, with a denser liquid resulting in a lower frequency.
  • Page 5: Product Design

    Product design...
  • Page 6: Plaato Cloud

    PLAATO Cloud The PLAATO Pro employs WiFi technology to establish a wireless connection to the cloud, providing robust range and connectivity in challenging brewery environments. This cloud-based feature offers the user the ability to remotely access fermentation data, enabling streamlined process monitoring from any location.
  • Page 7: Getting Started

    Correct installation and use is important to achieve the best results possible. Please carefully assess the steps below. 1. Install the Pro in a port that ensures minimum 50cm / 20” of liquid above the probe a. Insufficient head pressure due to low liquid levels above the Pro can result in CO2 bubbles, which can affect the probe and generate noisy data.
  • Page 8: How To Get The Best Possible Readings

    1. During the initial 60 minutes after the fermenter is filled, variations in temperature between the PLAATO Pro and the liquid may lead to inaccuracies and spikes in data. However, once the probes have equilibrated with the liquid temperature, the readings will stabilize.
  • Page 9: Quick Installation

    ● 1x PLAATO Connector ● 1x Power cable ● 1x Ethernet cable ● 2x C-cell batteries 1. Create your Plaato Pro Account Follow the steps in the “Account Creation Email” you’ve received from the PLAATO onboarding team to register your account.
  • Page 10 To set up the Pro Connector, connect it to power using the provided USB cable. Then, connect one end of the Ethernet cable to the "WAN" port on the Pro Connector and the other end to your WiFi router. The LED light on the Pro Connector should illuminate immediately.
  • Page 11 2. Powered on your PLAATO Pro To add your PLAATO Pro device to your account: 1. Download the PLAATO Pro App for iOS or Android from the Apple App Store or Google Play Store. 2. Log into the mobile app using your PLAATO Pro account credentials.
  • Page 12 1. Clean the wetted parts with an alkaline solution and gently brush. 2. Sanitize using an acid, chlorine or ethanol solution. 3. Install the device in a spare Tri Clamp port, adhering to the guidelines outlined in section 2.2 “PLAATO Pro - How to get the best possible readings".
  • Page 13: Installation

    Installation Placement on fermenter We recommend installing PLAATO Pro in a spare 1.5” Tri Clamp port on the fermenter, as shown below: The following criteria must be met when selecting a Tri Clamp port for installation of the PLAATO Pro: 1.
  • Page 14: Cleaning And Sanitizing Before Installation

    2. Gently scrub the device using a sponge 3. Rinse thoroughly with clean water 4. Sanitize using acid, chlorine, or ethanol. For further details regarding maintenance and cleaning of the PLAATO Pro, see chapter 6 Maintenance. Alignment When installing the device in the fermenter, it is important to level the built-in spirit level to ensure that the tines are correctly positioned, allowing for unimpeded passage of sedimentation and bubbles.
  • Page 15: Use Of T-Connectors

    T-connectors can result in insufficient insertion depth and inaccurate readings of specific gravity and temperature. Tri Clamp adapters Adapters can be used in-between the Pro and the fermenter if a 1.5” Tri-Clamp port is not available. DIN11851 adapters PLAATO has the following adapters available for purchase.
  • Page 16: Operation

    30 minutes during the measurement & transmit process. Reset-button Force new reading A single push will wake up the Pro and a new reading will be sent to the Cloud. Battery change The expected battery life is 3-6 months. To replace the batteries in the device, follow these steps: 1.
  • Page 17: Maintenance

    7. Rinse thoroughly with clean water 8. Sanitize using acid, chlorine, or ethanol. Note: Avoid submerging the PLAATO Pro in water or any other liquids. Beer stone Beer stone is a precipitate that can form on stainless steel surfaces, including the wetted parts of the PLAATO Pro.
  • Page 18: Safety And Usage Considerations

    Safety and Usage Considerations Handling Please handle the device with care. The fork / tines are sensitive, and must be protected from impacts. ● Avoid bend the fork ● Avoid holding the fork with your hands ● Avoid impacts between fork and other surfaces, such as the TC-port during installation Impact to the fork or wrong handling might offset calibration values, and can require a new calibration procedure.
  • Page 19: Designated Use

    Designated use The device described in Product Description may only be used as a density meter for liquids. Incorrect use may pose a hazard. Product safety This device is designed in accordance with good engineering practice to meet current safety requirements, and has left the factory in a condition in which it is safe to use.
  • Page 20: Technical Data

    Technical data Environment Storage temperature range -20 to +55°C (5 to 131 °F) Ambient temperature range 0 to +55°C (32 to 131 °F) Degree of protection ● Protected against water jets ● Complete protection against dust Reverse polarity protection Battery connection has reverse polarity protection Humidity Up to 100%.
  • Page 21: Technology

    Technology WiFi 802.11b/g/n, 2.4GHz Certifications FCC/CE Medium state Liquid Supply voltage Avg current consumption 10 mA Wetted materials Stainless steel 304 Battery 2x Alkaline, C-type (R14), 1.5V Measuring- and transmission rate Every 30th minute...
  • Page 22: Plaato Apps

    PLAATO Apps The PLAATO Pro Apps The PLAATO Pro fermentation data can be accessed through the PLAATO mobile applications and the Web App, which both use the same login credentials. The mobile apps are designed for monitoring data remotely and responding to process-critical notifications.
  • Page 23: Customize The Plaato Pro Apps

    ● Tap in on the existing name field, enter the new name of the device. ● Tap on "Save Device Name" to save Experimental Features To try out features that are currently under development on the Plaato Pro App, toggle on "Experimental Feature" in your Account Settings. 1. Launch your Plaato Pro App/Web App 2.
  • Page 24: Create A Recipe

    Create a Recipe Store all of your brewing recipes in one place and access it wherever you are, at any time with Plaato Pro's Recipe. To create your Recipes, follow the steps below. Plaato Pro Mobile App (iOS and Android) 1.
  • Page 25: Create A Batch

    Create a Batch Achieving the recipe of your dreams takes some practice, and monitoring your data over time. The Batches feature on Plaato Pro enables you to: ● Create and monitor multiple batches. ● Connect each batch to a Recipe.
  • Page 26 6. Tap on "Create Batch" 7. Go back to "Batches" and select the Batch you just created. Click on "Add a device" select a device and click on "Add Device" to link the right Plaato Pro device to the current batch.
  • Page 27: Compare Batches

    Compare Batches The PLAATO Pro Batch Comparison feature allows you to overlay the data from several batches and compare the data. Select up to 4 fermentation batches and layer the fermentation graphs over each other to compare and to learn what worked best during the batches, or what could be improved upon for your next batch.
  • Page 28 Filtering (Data Source) You have the option to select what unit to compare on the graphs. 1. Hover your mouse to the right of your graph to Data Source 2. Click on the eye icon to select or deselect Temperature or Density...
  • Page 29 Aligning the Batches (Graph) Using the sliders beneath the chart you also have the option to adjust and align the Start/End time of the Datasets across your selected batches 1. Hover your mouse over Graph Alignment 2. Click and drag the slider to adjust...
  • Page 30: Create Batch Alerts

    Create Batch Alerts Create a Batch Alert - PLAATO App (iOS & Android) Turn on Push Notifications on your mobile device Launch your Plaato Pro App and tap on "Batches". Select the batch you are interested in On the "Batch Details" screen, tap on "Alerts > Add Alert"...
  • Page 31 FAQ - Batch Alerts Can you create an alert for a recipe? No, alerts can only be created and linked to Batches Can I set up multiple alerts on a batch? Yes, you can create multiple alerts on a batch Can I mute a batch alert? No, you can only delete a batch alert Can I create a user specific batch alert?
  • Page 32: Rename Your Plaato Pro Device

    Rename your PLAATO Pro device Changing the name of your Plaato Pro Device is super quick and easy. Here is how: Plaato Pro Mobile App (iOS and Android) Launch your Plaato Pro App Go to "Devices" Click on the Plaato Pro device you want to export data from Scroll to the bottom of the page Click on "Export Data"...
  • Page 33: Export Plaato Pro Data

    Plaato Pro Mobile App (iOS and Android) Launch your Plaato Pro App Go to "Devices" Click on the Plaato Pro device you want to export data from Scroll to the bottom of the page Click on "Export Data" Your fermentation data will be sent to your registered email address immediately.
  • Page 34: Teams

    Add manual measurements 9.10 If the readings from your Plaato Pro device is off by a few points when compared to manual measurement readings, you can add the manual measurements to your Plaato Pro App for reference purposes.
  • Page 35: Plaato And Brewman: Integration

    To learn more about Brewman click here The Plaato and Brewman integration sends SG and Temperature from your Plaato Pro account to your Brewman account with no manual effort from you. Setting up your Plaato Pro and Brewman Integration 1.
  • Page 36 (Only users with Admin privileges would be able to generate an API Token) 3. Input that API Token/Key and click Save. After your API Key is entered, this will take you to a page that lists your active Plaato Pros and list them on the grid.
  • Page 37 On this Plaato screen, you can assign the probes you have to specific vessels within BrewMan. Click on the Action button (3 dots) and click Assign to Vessel. Now choose the vessel you wish this probe to be linked to.
  • Page 38: Plaato Pro Api

    PLAATO Pro API 9.12 Plaato Pro provides a rest API that can be used to connect it to third party applications. To learn more about our available Plaato Pro API, please view our documentation here Generate an API Authentication Token/Key Please note: To generate a Plaato Pro API Authentication Token/Key, you will need to have admin user privileges on your account.
  • Page 39: Troubleshooting

    4. Restart the Connector by disconnecting the power chord for 30 seconds 5. Move the Connector closer to the Pro 1. Ensure that Pro is turned on and that the batteries are not empty Inaccurate temperature readings The use of long (normal) T-connectors can cause the temperature to be inaccurate.
  • Page 40: Led Modes

    This error will be displayed by the device if it is not able to find the SSID of the Plaato Connect. Potential Issue: ● Plaato Connect to far away from the Plaato PRO ● Plaato Connect not setup correctly ● Plaato Connect does not have...
  • Page 41: Troubleshooting The Pro Connector

    3. Install the Connector 50cm / 20” higher up. Small changes in installation location can increase the WiFi strength significantly Reset the connection Disconnect and reconnect the power to the Pro Connector and check if the Pro reconnects. If the issue persists, please write to us at support@plaato.io.
  • Page 42: Other

    Other Repair and return 11.1 The device may only be repaired by PLAATO Technologies. Please get in touch with a representative for more information. Disposal 11.2 This marking on the product or on its packaging illustrates that, under European Directive 2012/19/EU governing used electrical and electronic appliances, this product may not be disposed of with normal household waste.
  • Page 43 PAGE INTENTIONALLY BLANK...
  • Page 44 PLAATO Pro - User Manual Version: 0.7 Date: 28.08.2023...
  • Page 45 IC Caution: This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause interference; and (2) This device must accept any interference, including interference that may cause undesired operation of the device. To maintain compliance with RF exposure guidelines, this equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body.