Advertisement

Quick Links

HMI
TP-smart | H71-A1A41-0 | Manual
HB160 | TP-smart | H71-A1A41-0 | en | 24-40
smartPanel - TP407-SM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TP-smart TP 407-SM and is the answer not in the manual?

Questions and answers

Summary of Contents for YASKAWA TP-smart TP 407-SM

  • Page 1 TP-smart | H71-A1A41-0 | Manual HB160 | TP-smart | H71-A1A41-0 | en | 24-40 smartPanel - TP407-SM...
  • Page 2 YASKAWA Europe GmbH Philipp-Reis-Str. 6 65795 Hattersheim Germany Tel.: +49 6196 569-300 Fax: +49 6196 569-398 Email: info@yaskawa.eu Internet: www.yaskawa.eu.com H71-A1A41-0_000_TP407-SM,1,EN - © 2024...
  • Page 3: Table Of Contents

    Copyright © YASKAWA Europe GmbH........
  • Page 4 Table of contents Integrated server..............3.8.1 FTP server.
  • Page 5: General

    Copyright © YASKAWA Europe GmbH All Rights Reserved This document contains proprietary information of Yaskawa and is not to be disclosed or used except in accordance with applicable agreements. This material is protected by copyright laws. It may not be reproduced, distributed, or...
  • Page 6: About This Manual

    General About this manual About this manual Objective and contents This manual describes the smartPanel H71-A1A41-0. ■ It contains a description of the structure, project engineering and deployment. ■ The manual is written for users with basic knowledge of automation technology. ■...
  • Page 7: Safety Instructions

    The customer must confirm that the Yaskawa product is suitable for the systems, machines, and equipment used by the customer. ■ If the Yaskawa product is used in a manner not specified in the manual, the protection provided by the Yaskawa product may be impaired. ■...
  • Page 8 Safety instructions ■ Exclusion of Liability The Yaskawa product is not suited for use in life-support machines or systems. ■ Contact a Yaskawa representative or your Yaskawa sales representative if you are considering the application of this Yaskawa product for special purposes, such as machines or systems used for passenger cars, medicine, airplanes and aerospace, nuclear power, electric power or undersea relaying.
  • Page 9: Hardware Description

    Hardware description Properties Hardware description Safety information for users Handling of electrostatic The modules make use of highly integrated components in MOS-Technology. These sensitive modules components are extremely sensitive to over-voltages that can occur during electrostatic discharges. The following symbol is attached to modules that can be destroyed by elec- trostatic discharges.
  • Page 10 Packaging unit 692-9AX00 3-fold connector for power supply 20 pieces smartPanel. CAUTION Please note that you may only use the spare parts with Yaskawa modules. Use with third-party modules is not allowed! HB160 | TP-smart | H71-A1A41-0 | en | 24-40...
  • Page 11: Structure

    Hardware description Structure > Overview Structure 2.3.1 Overview Front view Interfaces Display with touch sensitive area (touch screen) Bottom view USB-A interface USB 2.0 RJ45 jack for Ethernet communication LAN RS232/RS422/RS485 interface COM Slot for DC 24V voltage supply HB160 | TP-smart | H71-A1A41-0 | en | 24-40...
  • Page 12: Interfaces

    Hardware description Structure > Interfaces 2.3.2 Interfaces "Host"-USB-A Using the "Host"-USB-A interface USB mouse, keyboard, stick or USB hard discs can be connected. Ethernet connection The RJ45 jack provides the interface to the twisted pair cable, required for Ethernet. The Ethernet interface has got two LEDs for status display.
  • Page 13 Hardware description Structure > Interfaces RS422/485 interface 9 pin SubD jack ■ Logical states represented by voltage differences between the 4 cores ■ Serial bus connection in 4-wire technology using full duplex mode ■ Data communications up to a max. distance of 500m ■...
  • Page 14: Memory Management

    Hardware description Dimensions 2.3.3 Memory management Overview The following memory systems are available for the smartPanel: ■ 512MB work memory (RAM) ■ 4GB user memory (Flash) ■ USB storage media using "Host"-USB-A interface Work memory (RAM) The smartPanel has a work memory with a size of 512MB. The work memory is not buffered and is deleted after shut down.
  • Page 15: General Data For The Smartpanel

    Hardware description General data for the smartPanel The degrees of protection are only guaranteed when the following is observed: − Material thickness at the mounting cut-out: 1.5 ... 6mm − £ 0.5mm. This The deviation from the plane for the panel cut-out is condition must be fulfilled for the mounted HMI device.
  • Page 16: Use In Difficult Operating Conditions

    Hardware description Use in difficult operating conditions Mounting conditions Mounting place In the control cabinet Mounting position Horizontal and vertical Standard Comment Emitted interference EN 61000-6-4 Class A (Industrial area) Noise immunity EN 61000-6-2 Industrial area zone B EN 61000-4-2 8kV at air discharge (degree of severity 3), 4kV at contact discharge (degree of severity 2) EN 61000-4-3...
  • Page 17: Technical Data

    Hardware description Technical data Technical data Order no. H71-A1A41-0 Type smartPanel TP407-SM Display Display size (diagonal) 7 " Display size (width) 155 mm Display size (height) 88 mm Resolution 480 x 800 / 800 x 480 Aspect ratio 16:9 Type of display TFT color (64K colors) MTBF Backlights (25°C) 20000 h...
  • Page 18 Hardware description Technical data Order no. H71-A1A41-0 Serial, COM2 COM2 connector Number of USB-A interfaces USB-A connector USB-A (host) Number of USB-B interfaces USB-B connector Number of ethernet interfaces Ethernet Ethernet 10/100 MBit Ethernet connector RJ45 Integrated ethernet switch Video connectors Audio connections Technical data power supply Power supply (rated value)
  • Page 19 Hardware description Technical data Order no. H71-A1A41-0 Minimum 1.5 mm Maximum front panel thickness 6 mm Net weight 531 g Weight including accessories 584 g Gross weight 860 g Environmental conditions Operating temperature 0 °C to 50 °C Storage temperature -20 °C to 70 °C Certifications UL certification...
  • Page 20: Deployment

    Deployment Installation Deployment Installation Overview The smartPanel is suitable for the installation in operating tables and control cabinet fronts. The installation happens via the backside. The smartPanel is provided with a fixing technique that allows an easy connection with a crosstip screwdriver. A fast and easy device change is possible.
  • Page 21: Commissioning

    Deployment Commissioning ■ Connecting the power For wiring the DC 24V power supply (10 ... 32 VDC), a 3-fold connector with screw supply contacts is used, which is included in the scope of delivery. The corresponding label is located on the back of the smartPanel. ■...
  • Page 22 Deployment Commissioning IP address On delivery the smartPanel has the following IP address: ■ 192.168.1.100 You get valid IP address parameters from your system administrator. These can be specified in the ‘System Settings’ via Network. ⮫ Chap. 3.3.6 ‘Network’ ...page 24 Project transfer The smartPanel can only be configured with the HMI Designer.
  • Page 23: System Settings

    Deployment System Settings > Localisation System Settings 3.3.1 Overview Submenu The submenu is protected by access data. ⮫ ‘Access data’ ...page 22 After requesting the access data, you can access the basic settings of smartPanel via the following submenu items: ■ Localisation ■...
  • Page 24: System

    ■ Any open source software used in the product is subject to the respective licence terms, which are not affected by the Yaskawa Software Licence Terms (SLT) for the product. ■ The licensee can change the respective open source software in accordance with the applicable license terms.
  • Page 25: Security

    Deployment System Settings > Services Restore This will reset all network, firewall and router settings to their delivery state! 3.3.7 Security Credentials This function can only be accessed by a registered administrator. The security area contains passwords and certificates that are required for your applica- tions.
  • Page 26: Management

    Deployment System Settings > Management Enable device restore via When enabled, the USB stick can be used to restore factory settings if, for example, the administrator password is not known. For this, create an empty file without an extension with the name ‘device-factory-restore’ in the root directory. After the boot process, this file is detected on the USB stick and a reset to the factory settings is applied.
  • Page 27: Display

    Deployment Startup Sequence 3.3.11 Display Here a slider can be used to adjust the brightness of the display and the time until the automatic backlight turns off. After the set time elapses, the backlight is switched off and is activated again by touching the display. The ‘Orientation’...
  • Page 28: Tap-Tap Menu

    The Tap-Tap Menu can be accessed by quickly touching the screen in a certain order Menu during the start-up of the smartPanel. Switch on the smartPanel and wait until ‘Yaskawa’ is shown. Tap the screen several times in quick succession. �� You receive the message TAP-TAP DETECTED and find yourself in the Tap-Tap “TAP-TAP DETECTED 5“...
  • Page 29: Firmware Update

    In this case, please contact our hotline! Go to the ‘Download Center’ of www.yaskawa.eu.com. At ‘Firmware H71-A1A41-0’, download the appropriate zip file for your smartPanel to your PC.
  • Page 30: Connection To A Plc System

    Deployment Connection to a PLC system Connection to a PLC system ■ Overview To integrate it into your PLC system, the HMI Designer is to be used, which is to be installed on a PC. Here the project can be created and simulated if necessary and transferred to the smartPanel via Ethernet or a USB stick.
  • Page 31: Integrated Server

    Deployment Integrated server > FTP server Integrated server Overview The following servers are integrated in the smartPanel, which enable remote mainte- nance via Ethernet: ■ FTP server - Default: enabled ■ VNC server - Default: disabled ■ Web server - cannot be disabled Terms used to describe the servers: ■...
  • Page 32: Vnc Server

    Please also note that we cannot offer support for VNC functionality of the Yaskawa. Further information can be found at the manufacturer of the VNC viewer, which is also available as open source. Establishing a VNC connec- Start your smartPanel and open the ⮫ Chap.
  • Page 33: Industrial Security And Installation Guidelines

    Industrial security in information technology Latest version This chapter can also be found as a guide ‘Industrial IT Security’ in the ‘Download Center’ of www.yaskawa.eu.com Hazards The topic of data security and access protection has become increasingly important in the industrial environment. The increased networking of entire industrial systems to the network levels within the company together with the functions of remote maintenance have all served to increase vulnerability.
  • Page 34: Protection Of Hardware And Applications

    Industrial security and installation guidelines Industrial security in information technology > Protection of hardware and applications 4.1.1 Protection of hardware and applications ■ Precautions Do not integrate any components or systems into public networks. – Use VPN "Virtual Private Networks" for use in public networks. This allows you to control and filter the data traffic accordingly.
  • Page 35: Protection Of Pc-Based Software

    Industrial security and installation guidelines Installation guidelines 4.1.2 Protection of PC-based software Precautions Since PC-based software is used for programming, configuration and monitoring, it can also be used to manipulate entire systems or individual components. Particular caution is required here! ■...
  • Page 36 Industrial security and installation guidelines Installation guidelines Possible interference Electromagnetic interferences may interfere your control via different ways: causes ■ Electromagnetic fields (RF coupling) ■ Magnetic fields with power frequency ■ Bus system ■ Power supply ■ Protected earth conductor Depending on the spreading medium (lead bound or lead free) and the distance to the interference cause, interferences to your control occur by means of different coupling mechanisms.
  • Page 37 Industrial security and installation guidelines Installation guidelines ■ Create a homogeneous reference potential and ground all electrical operating supplies when possible. – Please take care for the targeted employment of the grounding actions. The grounding of the PLC serves for protection and functionality activity. –...

This manual is also suitable for:

H71-a1a41-0

Table of Contents