Summary of Contents for Roger Technology B70/1T
Page 1
IS271 Rev.00 22/09/2023 B70/1T centrale di comando 24Vdc per cancelli scorrevoli su colonna Istruzioni originali IT - Istruzioni ed avvertenze per l’installatore EN - Instructions and warnings for the installer DE - Anweisungen und Hinweise für den Installateur FR - Instructions et consignes pour l’installateur...
Page 3
Dispositivo IP B74/BCONNECT B74/BCONNECT IP device r1.00 Connessione RS485 Display a 4 cifre e 6 tasti Connettore ad innesto per master/slave di programmazione radio ricevente (utilizzo futuro) 4 digit display and 6 Plug-in connector for radio RS485 master/slave programming buttons receiver connection (future use)
Page 5
Scheda carica batteria B71/BC - B71/BC battery charger dal secondario del trasformatore from the secondary of the transformer BLACK AI MORSETTI 4,5 TO TERMINALS 4,5 2 x 12V 1,2Ah 2 x 12V 1,2Ah AGM Battery ONLY AGM Battery ONLY...
Page 6
H93/RX22A/I RICEVITORE RADIO ANTENNA RADIO RECEIVER B74/BCONNECT F2 FUSIBILE FUSE POWER IN F1 FUSIBILE FUSE F3 FUSIBILE FUSE (T2A @115Vac) 230 Vac (115 Vac)
Page 7
TW90 High Speed B72/BRCL rosso +24V nero +LAM black Marrone Brown B72/BRCL B72/BRCL...
Page 8
TW90 Reversibile / Reversible B72/BRCL rosso +24V nero +LAM black Marrone Brown NON COLLEGATO NOT CONNECTED B72/BRCL B72/BRCL...
Page 9
RG58 max 10 m Antenna Orologio / Timer Apertura / Opening Chiusura / Closing STOP Passo passo Step by step COS1 Apertura parziale Bordo sensibile 1 Safety edge 1 Partial opening +24V COS2 Bordo sensibile 2 Safety edge 2 Lampeggiante Flashing light +LAM Spia cancello aperto...
Page 10
COLLEGAMENTO CON 1 COPPIA FOTOCELLULE SINCRONIZZATE (MODALITÁ NORMALE, SOLO COPPIA MASTER) CONNECTION WITH 1 SYNCHRONISED PHOTOCELL PAIR (NORMAL MODE, MASTER PAIR ONLY) ROSSO = libero da jumper RED = jumper free JUMPER DI SINCRONIZZAZIONE (PER MASTER) SYNCHRONISATION JUMPER 1 2 3 (FOR MASTER) 1 2 3 JUMPER DI ALLINEAMENTO...
Page 11
COLLEGAMENTO CON 2 COPPIE FOTOCELLULE SINCRONIZZATE (MODALITÁ NORMALE, 1 MASTER E 1 SLAVE) CONNECTION WITH 2 SYNCHRONISED PHOTOCELL PAIRS (NORMAL MODE, 1 MASTER AND 1 SLAVE) ROSSO = libero da jumper RED = jumper free JUMPER DI SINCRONIZZAZIONE (PER MASTER) SYNCHRONISATION JUMPER 1 2 3 1 2 3...
Page 12
TEST FOTOCELLULE · PHOTOCELLS TEST (A8 02) COLLEGAMENTO CON 1 COPPIA FOTOCELLULE SINCRONIZZATE (MODALITÁ NORMALE, SOLO COPPIA MASTER) CONNECTION WITH 1 SYNCHRONISED PHOTOCELL PAIR (NORMAL MODE, MASTER PAIR ONLY) ROSSO = libero da jumper RED = jumper free JUMPER DI SINCRONIZZAZIONE (PER MASTER) SYNCHRONISATION JUMPER 1 2 3...
Page 13
TEST FOTOCELLULE · PHOTOCELLS TEST (A8 02) COLLEGAMENTO CON 2 COPPIE FOTOCELLULE SINCRONIZZATE (MODALITÁ NORMALE, 1 MASTER E 1 SLAVE) CONNECTION WITH 2 SYNCHRONISED PHOTOCELL PAIRS (NORMAL MODE, 1 MASTER AND 1 SLAVE) ROSSO = libero da jumper RED = jumper free JUMPER DI SINCRONIZZAZIONE (PER MASTER) 1 2 3...
Page 14
BATTERY SAVING (A8 03) BATTERY SAVING + TEST FOTOCELLULE · PHOTOCELLS TEST (A8 04) COLLEGAMENTO CON 1 COPPIA FOTOCELLULE SINCRONIZZATE (MODALITÁ NORMALE, SOLO COPPIA MASTER) CONNECTION WITH 1 SYNCHRONISED PHOTOCELL PAIR (NORMAL MODE, MASTER PAIR ONLY) ROSSO = libero da jumper RED = jumper free JUMPER DI SINCRONIZZAZIONE (PER MASTER)
Page 15
BATTERY SAVING (A8 03) BATTERY SAVING + TEST FOTOCELLULE · PHOTOCELLS TEST (A8 04) COLLEGAMENTO CON 2 COPPIE FOTOCELLULE SINCRONIZZATE (MODALITÁ NORMALE, 1 MASTER E 1 SLAVE) CONNECTION WITH 2 SYNCHRONISED PHOTOCELL PAIRS (NORMAL MODE, 1 MASTER AND 1 SLAVE) ROSSO = libero da jumper RED = jumper free JUMPER DI SINCRONIZZAZIONE...
Page 16
SENSORE MAGNETICO DI SBLOCCO MAGNETIC UNLOCKING SENSOR FINECORSA MAGNETICO MAGNETIC LIMIT SWITCH ENCODER è possibile acquistare il finecorsa separatamente it is possible to purchase the limit switch separately (cod. MC784 / MC785)
Failure to observe the information included in this manual may result in personal in serious personal injury or damage to the equipment. ROGER TECHNOLOGY cannot be held responsible for any damage or injury due to improper use or any use other than the intended usage indicated in this manual.
Page 18
Only use original spare parts when repairing or replacing products. The installer must provide the user with complete instruction for using the motorised door or gate in automatic, manual and emergency modes, and must hand the operating instructions to the user of the installation upon completion. Keep away from hinges and moving parts.
Product description The B70/1T controller is a unit for the SENSORED control, with a high resolution encoder, of a ROGER Brushless motor for automated sliding gates integrated in the column. Ensure that the parameter A1 is set correctly. If this parameter is not set correctly, the automation system may not function properly.
Description of connections To access the control connection terminal board, remove the motor cover as shown in figure 1: • remove the four screws and lift the cover If the B71/BC charger is installed, refer to figure 2: • pull out the drawer containing the charger and batteries. Figure 3-4-5-6-7 shows connection diagrams for connecting mains voltage to the motor control unit (B70/1T).
Mains power supply 230 V~ ±10%, fuse 5x20 T1A connection (115 V~ ±10% fuse T2A). POWER IN Power feed input from transformer (or from B71/BC battery charger - if used, fig. 2). N.B.: Ready wired in factory by ROGER TECHNOLOGY. WARNING! With the board powered the battery connected, pay maximum attention to the polarity (see fig. 2).
Page 22
73 00. 15(ST) 14(COM) STOP command input (NC). The current manoeuvre is arrested if the safety contact opens. N.B.: the controller is supplied with this contact already jumpered by ROGER TECHNOLOGY. 19(ANT) Antenna connector for slot-in radio receiver board. Use RG58 if an external antenna is used; maximum recommended length: 10 m. N.B.: do not make joints in cable.
Page 23
CONTACT DESCRIPTION 23(AP) 21(COM) Open control signal input (N.O.). WARNING: persistent activation of the opening command prevents automatic reclosure; the automatic reclosure time count is resumed when the opening command is released. 24(CH) 21(COM) Close command input (N.O.). 25(PP) 21(COM) Step by step mode command input (N.O.).
Function buttons and display BUTTON DESCRIPTION UP p Next parameter DOWN q Previous parameter DOWN Increase value of parameter by 1 Decrease value of parameter by 1 PROG Travel acquisition PROG TEST TEST Activate TEST mode • Press the UP p and/or DOWN q buttons to view the parameter you intend to modify. •...
Page 25
Display function modes Parameter display mode PARAMETER PARAMETER VALUE See chapter 12 for detailed descriptions of the parameters. Command and safety device status display mode COMMAND STATUS SAFETY DEVICE STATUS COS1 COS2 POWER STOP COMMAND STATUS: The command status indicators on the display are normally OFF. They ILLUMINATE when a command is received (e.g.: when a step mode command is received, the segment PP illuminates).
Page 26
TEST mode The TEST mode is used to test activation of the commands and safety devices with visual confirmation. To activate the mode, press the TEST button with the automatic door system at rest. If the gate is moving, pressing TEST stops the gate. Pressing the button again enables TEST mode. If the flashing light and the gate open indicator lamp illuminate for one second each time a control is used or a safety device is activated. The command signal status is shown on the left hand side of the display for 5 seconds, ONLY when the respective command signal is active (AP, CH, PP, PE, OR).
Travel acquisition For the system to function correctly, the gate travel must be acquired by the control. 10.1 Before starting: 1. Select the automation system model installed with the parameter A1. KEY: HIGH SPEED Motor REVERSIBLE Motor SELECTION MODEL MOTOR TYPE CONFIGURATION a1 01 TW90/800...
Page 28
10.2 Acquisition procedure: x5 s PROG AP P- PH A5 PH A5 FO TO AU to x4 s (if FT are connected or enabled) AU to OPENING OPEN CLOSING CLOSE • Press and hold PROG for 4 seconds. AP P- is shown on the display. •...
Page 29
10.3 Acquisition procedure without limit switches x5 s PROG AP P- PH A5 PH A5 FO TO AU to x4 s (if FT are connected or enabled) AU to OPENING OPEN CLOSING CLOSE • Press and hold PROG for 4 seconds. AP P- is shown on the display. •...
Index of parameters FACTORY PARAM. DESCRIPTION PAGE DEFAULT see chap. 12 Selecting automation system model Automatic closure after pause time (from gate completely open) Automatic gate closing after mains power outage Selecting step mode control function (PP) Pre-flashing Condominium function for partial open command (PED) Enabling operator present function Gate open indicator / photocell test function and “battery saving”...
FACTORY PARAM. DESCRIPTION PAGE DEFAULT Setting photocell mode during gate closing (FT2) Photocell (FT2) mode with gate closed Enable close command 6 s after activation of photocell (FT1-FT2) Limit switch enabling Setting motor stop distance Selecting installattion position of motor relative to gate (seen from interior side) Configuring sensing edge COS1 Configuring sensing edge COS2 Configuring radio channel 1 (PR1)
Parameters menu PARAMETER PARAMETER VALUE Selecting automation system model A1 01 WARNING! If this parameter is not set correctly, the automation system may not function properly. N.B.: in the event of a reset to restore the default parameters, this parameter must be set again manually. TW90/800 - IRREVERSIBLE motor for gate leaves up to 800 Kg.
Enabling operator present function a7 00 Disabled. Enabled. The open (AP) or close (CH) button must be pressed continuously to operate the gate. The gate stops when the button is released. Gate open indicator / photocell test function and “battery saving” a8 00 The indicator is off when the gate is closed, and steadily lit during manoeuvres and when the gate is open.
Enabling of management for opening with automatic re-closure exclusion 22 00 If enabled, the exclusion of automatic re-closure only applies for the command selected via the parameter. For example: if you set 2201, automatic re-closure is excluded following an AP command, but it is activated following a PP or PED command.
Maximum motor torque, 3 s of reaction time. Sensing edge is compulsory. Maximum motor torque, 5 s of reaction time. Sensing edge is compulsory. Setting start acceleration during opening and closing 33 04 See chapters 13 and 14 34 04 01= the gate accelerates rapidly at start of manoeuvre ...
Setting photocell mode during gate opening (FT1) 50 00 DISABLED. Photocell is not active or not installed. STOP. The gate stops and remains stationary until the next command is received. IMMEDIATE REVERSE. The gate reverses immediately if the photocell is activated during gate opening. TEMPORARY STOP.
Limit switch enabling 60 00 Limit switches disabled; programming the stroke and repositioning causes the sash to press on the mechanical stops, par. 25 and 26 adjust the stopping distance from these. Limit switches enabled; stroke programming and repositioning are managed by the activation of the magnetic opening and closing limit switches.
Configuring flashing light frequency 78 00 The frequency is set electronically from the flashing light unit. Slow flash. Light flashes slowly when gate opens, rapidly when gate closes. Selecting courtesy light mode 79 60 Disabled. PULSE. The courtesy light illuminates briefly at the start of each manoeuvre. ACTIVE. The light remains lit for the entire duration of the manoeuvre. From 3 to 90 s. The light remains lit for the time period set after the manoeuvre is completed. 03-90 92-99 From 2 to 9 minutes.
When the battery voltage drops under the threshold selected with par. 85, after a 5 s pre-flashing, the control unit automatically opens the barrier's boom and accepts only a closing command. It accepts only closing commands even if the ORO input is active and if the parameter is 80 01. When the battery voltage drops to the threshold selected with par.
Page 40
Password Setting a password prevents unauthorised persons from accessing the settings. With password protection active (CP=01), parameters may be viewed, but the values CANNOT be modified. Only a single password is used to control access to the gate automation system. WARNING: Contact the Technical Support Service if you lose your password. Password activation procedure: P1 00 •...
Page 41
Special parameters for High Speed series The High Speed (/HS) series is a family of digital Brushless high speed sliding motor units for sliding gates weighing up to 600 kg (TW90/600/HS) and dedicated exclusively to residential applications. High Speed technology makes it possible for the automation system to operate 100% faster than a conventional system, and allows independent management of speed, acceleration, deceleration and the safety devices used in the system.
Page 42
Special parameters for Reversible series The Reversible (/R) series is a family of digital brushless motor units for sliding gates weighing up to 800 kg (TW90/800/R) and dedicated exclusively to residential and industrial applications. REVERSIBLE technology makes it possible to open and close the gate without releasing the motor even in the event of power failure.
Page 43
Safety input and command status (TEST mode) With no currently active commands, press the TEST button and check the following: DISPLAY POSSIBLE CAUSE ACTION BY SOFTWARE PHYSICAL CORRECTIVE ACTION The release handle is open. Close the release handle and turn the key to the close position. (00 Sb) Check that the release contact is con- nected correctly.
Alarms and faults PROBLEM ALARM POSSIBLE CAUSE ACTION POWER LED off No power. Check power cable. POWER LED off Fuses blown. Replace fuses. Always disconnect from mains power before removing fuses. OF St Input mains power voltage fault. Disconnect from mains power, wait 10 seconds then reconnect to the mains and switch on.
Page 45
PROBLEM ALARM POSSIBLE CAUSE ACTION no PH Problems at the encoder circuit Check the integrity of the connection cable. or at the connection cable. Disconnect and reconnect the power supply. Give a command (opening / step-by-step, ...). The gate does not If noPH is NOT displayed, repeat the acquisition procedure. open or close.
Page 46
INFO MODE x5 s INFO mode may be used to view certain parameters measured by the B70/1T controller. Press and hold the TEST button for 5 seconds from the “View command signals and safety devices” mode with the motor stationary.
For further information consult the installation manual of the connection module B74/BCONNECT connection module. Remote assistance” mode Allows access and therefore the management of all the data of the control unit only in cloud mode and therefore with remote management. When remote assistance is enabled, the message ASCC (assistance connect controlled) appears on the display.
at the opposite limit switch takes place at the reduced speed set automatically (irrespective of the settings of parameters 13,14 and 42), recovering position control with maximum precision. • If, on the other hand, the leaf is in an intermediate position, it runs at reduced speed and the activation of one of the two limit switches allows immediate recovery of the position.
08:00 to 12:00 - 13:30 to 17:30 Telephone no: +39 041 5937023 E-mail: service@rogertechnology.it Skype: service_rogertechnology Declaration CE of Conformity The undersigned Dino Florian, legal representative of Roger Technology - Via Botticelli 8, 31021 Mogliano V.to (TV) DECLARES that the B70/1T digital control unit is compliant with the provisions established by Community directives: – 2014/35/UE LVD Standard – 2014/30/UE EMC Standard – 2014/53/UE RED Standard – 2011/65/UE RoHS Standard and that all the standards and/or technical requirements indicated as follows have been applied: EN 61000-6-3 EN IEC 61000-6-2 EN 60335-1 Place: Mogliano V.to Date: 03/06/2023 Signature...