Page 1
LED160 LED Marine Lantern Product Manual Version: 1.06 Date: November 17 2022 Date 20.11.2020 Version 1.05 Product Manual 0 of 1 LED160 SABIK Oy · Höylänlastu 2 A · FI 06150 Porvoo · Telephone +358 -19- 560 1100 · sabik-marine.com...
Page 2
03. Jul. 2014 First Version 0.90 01. Jul. 2014 First Draft Date 17.11.2022 Version 1.06 Product Manual 2 of 27 LED160 SABIK Oy · Höylänlastu 2 A · FI 06150 Porvoo · Telephone +358 -19- 560 1100 · sabik-marine.com...
TROUBLESHOOTING (Q&A) ........................25 APPENDIX A) EXPLOSION VIEW AND PART LIST ....................26 Date 17.11.2022 Version 1.06 Product Manual 3 of 27 LED160 SABIK Oy · Höylänlastu 2 A · FI 06150 Porvoo · Telephone +358 -19- 560 1100 · sabik-marine.com...
Introduction The LED160 Full Range Lantern for fixed and floating installations. The new design allows for internal GPS and GSM antennas, which makes the unit very durable and easy to install. Three different lantern options are available, covering a range from 3 Nm up to 12Nm (Tc = 0,74) Standard Features Standard IALA colors Red, Green, White, Yellow and Blue.
-40° – +60°C Operating temperature range 10 – 32 VDC Supply Voltage Solar panel charger Integrated 16 Ampere PWM charger 12W – 16W Power consumption LED160 Power consumption LED160H Max 36W Degree of protection IP 68 2.1. Optical performance Optical performance...
Product Identification and Options Every Sabik unit is supplied with a product label. Product label Option matrix for LED160 Product Options included Description LED160 OPT 9L LightGuard LTE-M + GPS Integrated GSM/GPS based monitoring including internal GSM/GPS antennas LED160 OPT 4L...
4.1. Mounting The LED160 unit is suitable for fixed and floating installations (buoys). The mounting flange supports installation on structures using 3 x M12 bolts or 4 x M12 bolts on a 200mm radius, a common mounting arrangement for marine lanterns.
Electrical The LED160 lantern can be operated on solar system, or on mains power system using an AC/DC converter. The built-in solar panel regulator makes it easy to use solar power for the lantern. In section 5.2 the connection of various type of power supplies are explained.
Especially the ripple, the transient current capability and inductance should be checked against the requirement of the lantern. Date 17.11.2022 Version 1.06 Product Manual 11 of 27 LED160 SABIK Oy · Höylänlastu 2 A · FI 06150 Porvoo · Telephone +358 -19- 560 1100 · sabik-marine.com...
Please contact your dealer to obtain these. This procedure has only to be done once. Date 17.11.2022 Version 1.06 Product Manual 12 of 27 LED160 SABIK Oy · Höylänlastu 2 A · FI 06150 Porvoo · Telephone +358 -19- 560 1100 · sabik-marine.com...
Tap on the name to select it. Date 17.11.2022 Version 1.06 Product Manual 13 of 27 LED160 SABIK Oy · Höylänlastu 2 A · FI 06150 Porvoo · Telephone +358 -19- 560 1100 · sabik-marine.com...
Expanded view for advanced settings. Tap the symbol to collapse. Date 17.11.2022 Version 1.06 Product Manual 14 of 27 LED160 SABIK Oy · Höylänlastu 2 A · FI 06150 Porvoo · Telephone +358 -19- 560 1100 · sabik-marine.com...
Page 15
If the set value is too high or low, a warning message is shown and the value cannot be stored. Date 17.11.2022 Version 1.06 Product Manual 15 of 27 LED160 SABIK Oy · Höylänlastu 2 A · FI 06150 Porvoo · Telephone +358 -19- 560 1100 · sabik-marine.com...
Measured LED Current Measured LED Voltage Lantern Tilt Angle LED Max Intensity Date 17.11.2022 Version 1.06 Product Manual 16 of 27 LED160 SABIK Oy · Höylänlastu 2 A · FI 06150 Porvoo · Telephone +358 -19- 560 1100 · sabik-marine.com...
Set lantern Sync mode (Off, Cable, GPS or Cable and GPS) Advanced Setting Sync Delay: Set Sync Delay (sec) Date 17.11.2022 Version 1.06 Product Manual 17 of 27 LED160 SABIK Oy · Höylänlastu 2 A · FI 06150 Porvoo · Telephone +358 -19- 560 1100 · sabik-marine.com...
The command is not needed when a lantern is equipped with GPS receiver. Date 17.11.2022 Version 1.06 Product Manual 18 of 27 LED160 SABIK Oy · Höylänlastu 2 A · FI 06150 Porvoo · Telephone +358 -19- 560 1100 · sabik-marine.com...
Page 19
Tap Save, when done. The new character will be saved as Custom. Date 17.11.2022 Version 1.06 Product Manual 19 of 27 LED160 SABIK Oy · Höylänlastu 2 A · FI 06150 Porvoo · Telephone +358 -19- 560 1100 · sabik-marine.com...
FL1...FL9: Light on times in one cycle (seconds). EC...EC9: Light off times in one cycle (seconds). Date 17.11.2022 Version 1.06 Product Manual 20 of 27 LED160 SABIK Oy · Höylänlastu 2 A · FI 06150 Porvoo · Telephone +358 -19- 560 1100 · sabik-marine.com...
Page 21
2,00 080 ISO 5S 50,0% 80 ISO 5S 50% 2,50 Date 17.11.2022 Version 1.06 Product Manual 21 of 27 LED160 SABIK Oy · Höylänlastu 2 A · FI 06150 Porvoo · Telephone +358 -19- 560 1100 · sabik-marine.com...
Page 22
0,20 160 VQ 0.6S 50,0% 160 VQ 0.6S 50% 0,30 Date 17.11.2022 Version 1.06 Product Manual 22 of 27 LED160 SABIK Oy · Höylänlastu 2 A · FI 06150 Porvoo · Telephone +358 -19- 560 1100 · sabik-marine.com...
Page 23
230 OC 2s 62,5% 230 OC 2s 63% 1,25 1,25 0,75 Date 17.11.2022 Version 1.06 Product Manual 23 of 27 LED160 SABIK Oy · Höylänlastu 2 A · FI 06150 Porvoo · Telephone +358 -19- 560 1100 · sabik-marine.com...
Periodic Maintenance The LED160 is a robust lantern, which requires no maintenance, except for periodical lens cleaning. To maintain a good light output and achieve a long service life, it is advisable to visually inspect the lantern whenever visiting the site.
Date 17.11.2022 Version 1.06 Product Manual 25 of 27 LED160 SABIK Oy · Höylänlastu 2 A · FI 06150 Porvoo · Telephone +358 -19- 560 1100 · sabik-marine.com...
APPENDIX A) Explosion view and part list Date 17.11.2022 Version 1.06 Product Manual 26 of 27 LED160 SABIK Oy · Höylänlastu 2 A · FI 06150 Porvoo · Telephone +358 -19- 560 1100 · sabik-marine.com...
Page 27
Date 17.11.2022 Version 1.06 Product Manual 27 of 27 LED160 SABIK Oy · Höylänlastu 2 A · FI 06150 Porvoo · Telephone +358 -19- 560 1100 · sabik-marine.com...