Summary of Contents for Aaronia BPSG 4

  • Page 1 HF Signal Generator USER MANUAL Please read the following instructions carefully before using your Aaronia HF signal generator. carefully. These instructions contain important information on the correct operation of this de- vice. www.aaronia.com...
  • Page 2: Table Of Contents

    1.4. Scope of delivery TECHNICAL DATA Technical Data HARDWARE 3.1. Connections (BPSG 4 and BPSG 6) 3.2. Connections (BPSG 4 OEM and BPSG 6 OEM) 3.3. Pin assignment OEM versions 3.4. Battery / Charger APPLICATION EXAMPLES Application examples INITIAL START-UP...
  • Page 3 TABLE OF CONTENTS SOFTWARE 6.5. Expert Mode 6.6. Device Information 6.7. Firmware Update 6.8. Printable version of the software 6.9. Languages INFORMATION 7.1. Description / Types | Safety instructions 7.2. Disposal | Technical data | CE conformity MORE ABOUT US AARONIA.COM www.aaronia.com...
  • Page 4: Introduction

    MCS software pliance. Never bring the appliance into contact with provided free of charge, Aaronia AG does not guar- water. Do not use it in the rain. Avoid excessively antee its suitability for purposes that have not been high temperatures.
  • Page 5: Scope Of Delivery

    Please check the contents of the package for com- SMA cable (1, 5, 10 meters) pleteness before commissioning. If any parts are  SMA to N adapter missing, contact Aaronia or your Aaronia dealer im-  12V car power supply adapter mediately. ...
  • Page 6: Technical Data

    2. TECHNICAL DATA HF SIGNAL GENERATOR BPSG 4 BPSG 6 BPSG 4 OEM BPSG 6 OEM Type Portable signal generator Portable signal generator OEM signal generator OEM signal generator Frequency range 35 MHz to 4,4 GHz 23,5 MHz to 6 GHz...
  • Page 7: Hardware

    3. HARDWARE Connectors BPSG 4 & BPSG 6 Status LED Charging LED 10 MHz reference clock input (max 3.3 V; optional) Power supply socket On/Off switch HF output USB connection (no charging function) www.aaronia.com...
  • Page 8: Connections (Bpsg 4 Oem And Bpsg 6 Oem)

    3. HARDWARE HF SIGNAL GENERATOR Connectors BPSG 4 OEM & BPSG 6 OEM 2x3 connection 10 MHz reference clock input (2.54 mm spacing) (max 3.3 V; optional) 2x4 connection (2.00 mm spacing) HF output 90° Housing brackets and screws USB connection...
  • Page 9: Pin Assignment Oem Versions

    (anode; can be connected directly to an LED, anot- her pin must be connected to GND) • Pin 5: GND (for USB) • Pin 6: GND (for USB) • Pin 7: GND (For USB) • Pin 8: GND (For USB) www.aaronia.com...
  • Page 10: Application Examples

    • Automatic Test Equipment (ATE) EMC tests. • Sweep and frequency hopping Many Aaronia antennas can be converted into an • Scalar Network Analyzers (SNA) active field strength generator with the BPSG in just • Electronic warfare (EW) with complex waveforms a few simple steps.
  • Page 11: Initial Start-Up

    Here you will find, among other things, a forum with many helpful tips & tricks, e.g. for operating the HF signal generators. The forums are open to everyone. After a short registration you can ask questions yourself and exchange information with other Aaronia users. aaronia.com/forum v6-forum.aaronia.de...
  • Page 12: Main Window

    6. SOFTWARE HF SIGNAL GENERATOR Main window Here you can see the main window of the software without the generator connected. The operating functions for the gene- rator are deactivated. No liability is accepted for printing errors and mistakes that may have occurred during the production of this user manual.
  • Page 13: General Operating Elements

    Selecting the design of the program interface Manual Mode Generates the set frequency with the set level Help Program Mode Displays the operating instructions Execute or create batch programs About Expert Mode Displays information about the software This mode is only intended for experts www.aaronia.com...
  • Page 14: Manual Mode

    6. SOFTWARE HF SIGNAL GENERATOR Manual Mode | Program Mode      REFERENCE FREQUENCY An external reference of 10 MHz can be selec- Enter the frequency of the output signal (de- ted here. pending on the generator type). ...
  • Page 15: Program Editor

     16). translation of the program. This function is not The data of the current program section. More required for operation.  on this in the explanation of the individual Writes the current settings to the device.  modes. www.aaronia.com...
  • Page 16: Program Modi

    6. SOFTWARE HF SIGNAL GENERATOR Program Modes | Sweep | Constant Wave Sweep Runs evenly through a frequency range from As start and end power can be set separately, you start to stop. If no step width is specified, can also run a “power ramp” or both at the same time. the smallest possible step width is selected.
  • Page 17: Amplitude Modulation

    1 Hz 60 Hz 900 MHz 949 MHz 1 MHz 3 MHz 1 Hz 50 Hz 950 MHz 2800 MHz 1 MHz 1 MHz 1 Hz 10 Hz 2801 MHz 5999 MHz 1 MHz 1 MHz 1 Hz 4 Hz www.aaronia.com...
  • Page 18: Pulse Modulation

    6. SOFTWARE HF SIGNAL GENERATOR Pulse Modulation | Repeat Pulse Modulation The output level is switched on in time with the pul- A pulse length of 0 results in a pulse of approx. 8 se frequency for the duration of the pulse length. microseconds.
  • Page 19: Software

    “Dump Memory”, the flash content can be read out they are transmitted with “Send”. and saved to a file. We recommend that only experts who are familiar with the hardware use this mode! Aaronia does not offer support for the expert mode. www.aaronia.com...
  • Page 20: Device Information

    6. SOFTWARE HF SIGNAL GENERATOR Device Information | Firmware Update Device Information With “Device”, a generator can be selected from the The name of the generator can be changed and writ- list of available generators. “Refresh” updates this ten with “Write Info”. To ensure proper functioning, list.
  • Page 21: Printable Version Of The Software

    Click on the “OK” button to activate the language. ges. Open the “Extras” menu and select “Select The language setting is automatically saved as the Language”. A dialog box is displayed. Select your default language for the next start of the application. language, if available. www.aaronia.com...
  • Page 22: Information

    BPSG 4 (35 MHz - 4,4 GHz | Art. Nr. 401/001) BPSG 4 (35 MHz - 4.4 GHz | Item No. 401/001) BPSG 4 OEM (35 MHz - 4,4 GHz | Art. Nr. 401/002) BPSG 4 OEM (35 MHz - 4.4 GHz | Item No. 401/002) BPSG 6 (23,5 MHz - 6 GHz | Art.
  • Page 23 Never dispose of batteries/battery packs in normal house- » » Hausmüll. Sie können verbrauchte Batterien/Akkus bei hold waste. You can dispose of used batteries/accumulators Ihrem Fachhändler oder an speziellen Entsorgungsstellen free of charge at your specialist dealer or at special disposal unentgeltlich entsorgen. points. www.aaronia.com...
  • Page 24: Disposal | Technical Data | Ce Conformity

    Die Aaronia AG ist nicht für Produktschäden auf Grund von Aaronia AG is not liable for product damage due to external äußeren Einflüssen, Verschleiß oder unsachgemäßer Hand- influences, wear or improper handling, unauthorized repair, habung, unbefugter Instandsetzung, Modifikationen oder modifications or accidents.
  • Page 25 8. NOTES www.aaronia.com...
  • Page 26 HF SIGNAL GENERATOR Aaroniaweg 1 Phone: +49 6556 900310 54597 Strickscheid eMail: mail@aaronia.de Germany Web: www.aaronia.com No liability is accepted for printing errors and mistakes that may have occurred during the production of this user manual.