Triac/0-10V/1-10V/Potentiometer/10V PWM 5 in 1 Dimmable LED driver 600W Specification Model KVG-24600-DW KVG-36600-DW KVG-48600-DW Certificate UL / FCC / Class P / CE / Rohs / REACH DC Voltage Voltage Tolerance ±0.5V Voltage Regulation ≤0.5% Output Rated current 16.67A 12.5A Rated power 600W Load Regulation...
Page 3
Triac/0-10V/1-10V/Potentiometer/10V PWM 5 in 1 Dimmable LED driver 600W Efficiency Curve (efficiency vs output load) Derating Curve (output load vs TEMP.) To extend their life, please refer to the Derating Curve and derate according to the temperature. Please note that the rise in temperature of LED fixtures over a long period of time will cause their power to rise. Therefore, we recommend the power supply to reserve a certain amount of load to avoid overloading .
Triac/0-10V/1-10V/Potentiometer/10V PWM 5 in 1 Dimmable LED driver 600W Power Factor Curve Mechanical Specification 24V&36V&48V Version Input cable 3*18AWG, the Green cable to (G), Black cable to (L), and White cable to (N) of Mains AC. 4 / 7 www.scpower.net.cn/en info@scpower.net.cn...
Triac/0-10V/1-10V/Potentiometer/10V PWM 5 in 1 Dimmable LED driver 600W Output cable 3*2*14AWG(24V/36V/48V), Red cable (+) to LED Positive side (+), Black cable (-) to LED Negative side (-). Dimming cable 2*18AWG, Purple cable DIM (+) to 0/1-10V dimmer signal(+ ), Pink cable DIM (-) to 0/1-10V dimmer signal (-). Please DO NOT connect “DIM-“...
Page 6
Triac/0-10V/1-10V/Potentiometer/10V PWM 5 in 1 Dimmable LED driver 600W Dimming Operation and Connecting Diagram Using two ways of dimming at the same time , you must be assured that LED lighting is up to the max. Brightness then you could operate with the other dimming; Using one dimming ---TRIAC/Phase cut dimming ...
Page 7
Triac/0-10V/1-10V/Potentiometer/10V PWM 5 in 1 Dimmable LED driver 600W Instruction Before use, confirm whether the rated input voltage of the power supply is within the mains voltage range; Pay attention to the distinction between power input and output lines to avoid power damage or unnecessary safety accidents caused by reverse connection;...