Big Dutchman AC 108 Operating Manual

Alarm device

Advertisement

Quick Links

Operating Manual
Alarm Device AC 108
Code No. 99-97-1861 GB
Edition: 10/2012

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AC 108 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Big Dutchman AC 108

  • Page 1 Operating Manual Alarm Device AC 108 Code No. 99-97-1861 GB Edition: 10/2012...
  • Page 2 Big Dutchman Pig Equipment GmbH P.O. Box 1163 D - 49360 Vechta Germany phone: +49 (0) 4447/801-0 fax +49 (0) 4447/801-237 e-mail: big@bigdutchman.de website: www.bigdutchman.de Copyright Any translation, transfer to third parties, reproduction or distribution is strictly prohibited without our prior consent.
  • Page 3: Table Of Contents

    Ended Alarm ..........................25 Connections ............................. 26 Starting Operation ..........................2 7 Maintenance ............................2 9 Daily ............................29 Every Three Years ........................29 Technical Data ..........................3 0 Spare parts ............................31 AC 108 Edition 10/12 M 1861 GB...
  • Page 4 4 Contents EC-Declaration of Conformity ......................3 4 AC 108 Edition 10/12 M 1861 GB...
  • Page 5: Safety

    These components should be arranged in such a manner so that they can be properly seen and heard. AC 108 Edition 10/12 M 1861 GB...
  • Page 6: Surge Protection

    (Arbeitsgemeinschaft für Elektrizitätsanwendung in der Landwirtschaft e.V. – AEL) • “Intensive Animal Husbandry – Alarm System Concepts for Buildings Used in Animal Husbandry“ – Association of the German Insurance Sector (Gesamtverband der Deutschen Versicherungswirtschaft e.V. – GDV) AC 108 Edition 10/12 M 1861 GB...
  • Page 7: Design

    The user can also set the preferred alarming modes. The device can be configured for numerous parameters, e.g. adding telephone numbers or creating individual alarm texts. Owing to a built-in back-up battery, the continuous operation of the alarm system is ensured even during power failure. AC 108 Edition 10/12 M 1861 GB...
  • Page 8: System Scheme

    6 Alarm contacts 3 Alarm siren *) 7 Temperature sensors 4 Flash lamp *) *) = The availability of certain functions depends on whether the marked components are part of the purchased alarm system. AC 108 Edition 10/12 M 1861 GB...
  • Page 9: System Setup

    10 power suply 5 Back-up batteryMains adapter 11 cover switch 6 Connecting mobile phone antenna *) = The availability of certain functions depends on whether the marked components are part of the purchased alarm system. AC 108 Edition 10/12 M 1861 GB...
  • Page 10: Sim Card

    SMS messages are disabled. Due to the above reasons, in order to ensure continuous operation of the alarm system, we propose the use of a contract based mobile service exclusively. AC 108 Edition 10/12 M 1861 GB...
  • Page 11: Operation

    (Up/Down buttons) 4 ESC button (Cancel, change view) 2 Display Views / Entering Parameters The display is capable of indicating two views. Navigating between the views is possible via using the “ESC button”. AC 108 Edition 10/12 M 1861 GB...
  • Page 12: Main View

    If the alarm is accepted (for further details please see chapter “Alarms”), the alarm text will stop flashing, instead, it will be shown permanently. AC 108 Edition 10/12 M 1861 GB...
  • Page 13: Setting View

    Editing parameters can be quit if the changed parameter value is confirmed by the “ENTER button”. The editing of parameters can also be stopped by pressing the “ESC button” (in this case, the changed value is not selected, neither confirmed). AC 108 Edition 10/12 M 1861 GB...
  • Page 14: Entering Messages / Telephone Numbers

    If the alarm device is not set to “AUTO” mode when the device is started, the system will automatically change the mode to “AUTO” (depending on what value was previously given for the “Reactivation” parameter). AC 108 Edition 10/12 M 1861 GB...
  • Page 15: Alarm Status

    (button cell) is improperly charged and displays the indicated alarm. Note: This alarm does not set off the alarm siren, nor does it launch any phone calls or SMS messages! AC 108 Edition 10/12 M 1861 GB...
  • Page 16 40 sec to save the recorded message. Other alarm functions of the system are not availabale during this time. *) = Marked alarms are available depending on the number of components belonging to the alarm system. AC 108 Edition 10/12 M 1861 GB...
  • Page 17: Parameter Setting

     deselected alarm contacts and temperature sensors  confirmed alarms  change Mode to “AUTO“ mode Parameter values can be set in hours. If the parameter is set to “OFF”, no automatic reactivation will take place. AC 108 Edition 10/12 M 1861 GB...
  • Page 18 0 °C Any measurement inaccuracies of the temperature sensor or wiring (length of the wiring) can be corrected. Note: The alarm text to be displayed can be set within a different parameter! AC 108 Edition 10/12 M 1861 GB...
  • Page 19 0 sec ▪ horn Setting the time to elapse between the occurrence of a new alarm situation and an delay 0 min alarm notification by the horn (alarm siren). AC 108 Edition 10/12 M 1861 GB...
  • Page 20 ”+“ sign (e.g. “+49” for ▪ phone nb. 3.call Germany). 000000000000000 The telephone numbers on the left were given ▪ for illustration purposes. phone nb. 3.SMS 000000000000000 ▪ phone nb. 4.call 000000000000000 ▪ phone nb. 4.SMS 000000000000000 AC 108 Edition 10/12 M 1861 GB...
  • Page 21 The displayed value facilitates the identification of the error which can be eliminated by the manufacturer only. *) = Marked parameters can be set depending on the number of components belonging to the alarm system. AC 108 Edition 10/12 M 1861 GB...
  • Page 22: Recording Verbal Messages

    Note: In case the device is successfully recording the verbal message a “Voice buffering active” signal will be displayed for approximately 40 sec. The device is saving the recorded message during this time interval and thus no other functions are available. AC 108 Edition 10/12 M 1861 GB...
  • Page 23: Alarms

    SMS messages is activated. Note: Automatic repetition stops after a maximum of 5 notifications. Note: Telephone calls and SMS messages are initiated only if the entered telephone numbers are valid and delay times are properly set! AC 108 Edition 10/12 M 1861 GB...
  • Page 24: Alarm Confirmation

    (i.e. there is a free tone signal). If the modem is unable to receive the call (i.e. there is a busy line signal or the voice mail begins to record), the call is not accepted and the alarm is not confirmed. AC 108 Edition 10/12 M 1861 GB...
  • Page 25: Ended Alarm

    Main View is deleted • the alarm siren stops giving a signal • the flash lamp stops operation • outstanding calls and SMS messages are not initiated by the system. AC 108 Edition 10/12 M 1861 GB...
  • Page 26: Connections

    *) = Marked alarm contacts are available depending on the number of components belonging to the alarm device. Note: All alarm contacts are equipped with insulated electrical connections. Note: Unused alarm contacts and temperature sensors are to be kept in an electric bridge. AC 108 Edition 10/12 M 1861 GB...
  • Page 27: Starting Operation

    Check the values indicated by the temperature sensors. Compare the indicated values to the values measured by a thermometer and by means of the below parameters ▪ temp. Temperature 1 / 2 offset X °C set the actual temperature values. *) AC 108 Edition 10/12 M 1861 GB...
  • Page 28 • Check if the alarms are created in the manner described in the User Manual. *) Marked settings can be performed depending on the number of components beloging to the alarm device. AC 108 Edition 10/12 M 1861 GB...
  • Page 29: Maintenance

    The battery should be replaced once in three years. Note: After four years the alarm device will automatically indicate that the battery needs to be replaced by displaying “alarm: battery interval“. Note: For replacement purposes, please use only original batteries! AC 108 Edition 10/12 M 1861 GB...
  • Page 30: Technical Data

    12V DC, ± 20 % max. 1 A output flash lamp 12V DC, ± 20 % max. 1 A *) = The number of marked connections depends on the number of components belonging to the alarm device. AC 108 Edition 10/12 M 1861 GB...
  • Page 31: 10 Spare Parts

    Recifier Type 60-43-4974 character semiconductor diode housing P600 weight voltage V DC current *) = The availability of certain functions depends on whether the marked components are part of the purchased alarm system. AC 108 Edition 10/12 M 1861 GB...
  • Page 32 (WxHxD) 250 x 180 x 0,9 colour grey/black weight keys *) = The availability of certain functions depends on whether the marked components are part of the purchased alarm system. AC 108 Edition 10/12 M 1861 GB...
  • Page 33 Spare parts page 33 Chart 6: Antenna GSM-antenna for alarm unit AC108 Type 60-43-4981 Cord length Insulation IP54 Connection FME connection Warning horn with warning light 12V/100mA Type 60-48-3852 AC 108 Edition 10/12 M 1861 GB...
  • Page 34: Ec Declaration Of Conformity

    The safety and installation requirements of the product documentation must be observed. Manufacturer: enacon, Everkekamp 11, D-59269 Beckum, Germany Device: GSM-Alarmgerät Type: AC 108 (gsm-al-1) Directive: EMC directive 2004/108/EG Low voltage directive 2006/95/EG European Standard: RF spectr. efficiency EN 301 511: v9.0.2 EMV EN 301 489-1: v1.8.1...

Table of Contents