NOT be covered under warranty . IMPORTANT: Airmax is not responsible for equipment damage or failure, losses, injury or death resulting from failure to follow safety precautions, misuse or abuse of equipment.
Page 3
7.5 HP 230v PRODUCT CONTENTS: Airmax 230v 3 PH Control Panel 7.5 HP Airmax 10 HP 230V Component Location Airmax TIMER Airmax TIMER 7.5 HP 230v REPLACEMENT PARTS: 10 HP 230 Volt Item Description Part Number Item Description Part Number...
Page 4
10 HP 230v PRODUCT CONTENTS: Airmax 230v 3 PH Control Panel 10 HP Airmax 10 HP 230V Component Location Airmax TIMER Airmax TIMER 10 HP 230v REPLACEMENT PARTS: 10 HP 230 Volt Item Description Part Number Item Description Part Number...
Page 5
Field Wiring Diagram: NOTE: Incoming wire colors will vary by site Control Panel 230v 115v 230v 3-Phase Power Supply 3-Phase Main Breaker Panel Delta or Wye 3-Phase Motor Lights airmaxeco.com | 866-424-7629...
7.5 – 10 HP 230v INSTALLATION INSTRUCTIONS: Airmax Control Panels are designed for outdoor use but should be mounted above any high water levels . Holes should be drilled into the bottom of the control panel for electrical access . We recommend using grommets to protect and seal the electrical access points and to help keep the control panel clean .
Page 7
Checking Incoming Control Panel Wiring for Correct Motor Rotation: Once all incoming power has been provided for the Airmax 3-phase control panel, one final check for proper motor rotation is key to a successful installation . Using a 3-Phase Sequence Rotation Tester will save time on site .
Page 8
7.5 HP 230v CONTROL PANEL WIRING SCHEMATIC: • Main Disconnect Supplied and Installed by Licensed Electrician • Input Hubs Must Comply With UL 514B *Shall Be Provided By Installer C3 S32 Contactor 3 Phase B reaker 115V Motor Timer 1 pole B reaker 230V 3 PH FLA 40A MIN SERVICE...
Page 9
10 HP 230v CONTROL PANEL WIRING SCHEMATIC: • Main Disconnect Supplied and Installed by Licensed Electrician • Input Hubs Must Comply With UL 514B *Shall Be Provided By Installer C3 S32 Contactor 3 Phase B reaker 115V Motor Timer 1 pole B reaker 230V 3 PH FLA 40A MIN SERVICE...
CREATING A PROGRAM Reset Button The Airmax Digital Timer allows up to 16 ON/OFF run times . Select the days for each run time to occur based on the 15 preset schedule of days shown in the table . (Fig . 1 - on the next page) Note: Ponds will receive the most benefit from continual water movement .
Maintenance & Operation of the Control Panel Timer Cont.: DAYS FOUNTAIN IS RUNNING Fig. 1 EDITING A PROGRAM Review a Program – To review the list of current programs, press the TIMER button repeatedly to scroll through the programs . When finished press the CLOCK button to return to the time of day .
WARRANTY: Airmax Control Panels are covered under the system warranty (5 Years – LakeSeries) THANK YOU FOR CHOOSING: Airmax, Inc. 15425 Chets Way Street, Armada, MI 48005 866-424-7629 | www .airmaxeco .com | contactus@airmaxeco .com #653920 V1 airmaxeco.com | 866-424-7629...
Need help?
Do you have a question about the 654193 and is the answer not in the manual?