Preface P. 1 Safety Precautions P. 1 Suggestions & Cautions P. 2 Components of Nozzle P. 3 Disassembly P. 4 Assembly P. 4 Maintenance P. 5 Troubleshooting P. 5 Disposal P. 6 Inquiries P. 6 H. Ikeuchi & Co., Ltd.
CERJET Preface Thank you for purchasing our CERJET® Spray Nozzle from H. Ikeuchi & Co., Ltd. This manual gives detailed instructions for the basic handling, maintenance and cautions of the CERJET® Spray Nozzle. Please take note that due to our continuous efforts to improve our products, the details in this manual may differ from the actual product.
Take special care when screwing in and unscrewing to prevent damage. Always apply an anti-seizing or sealing agent to the threads before assembly. H. Ikeuchi & Co., Ltd. -2-...
(2) Dimensions and materials may differ depending on product codes. (3) In the material code, "S" represents "stainless steel". For example, S303 stands for stainless steel 303. H. Ikeuchi & Co., Ltd. -3-...
+/-0.5 mm of the specified value, tighten everything with a spanner. Specified value: 2 mm for GSIM**75II or 110II 1 mm for GSIM**37II or 55II The gap must be less than +/-0.5 mm of the above values. H. Ikeuchi & Co., Ltd. -4-...
・ Nozzle or pipe is clogged. ・Clean the nozzle or pipe. Irregular ・ Nozzle tip is corroded. ・Replace the corroded part. spray ・Clean the parts. ・ Dust or foreign particles adhered on pattern the orifices H. Ikeuchi & Co., Ltd. -5-...
8. Inquiries For spare parts or any trouble, contact your supplier or the following: Daiichi Kyogyo Bldg., 1-15-15, Awaza, Nishi-ku, Osaka 550-0011 Japan Tel: +81-6-6538-4015 Fax: +81-6-6538-4022 e-mail: overseas@kirinoikeuchi.co.jp http://www.kirinoikeuchi.co.jp/eng/ H. Ikeuchi & Co., Ltd -6-...
Need help?
Do you have a question about the CERJET GSIM II Series and is the answer not in the manual?
Questions and answers