Bromic Heating 2850205 Instruction Manual And Users Manual

Instant boiling water dispensers 2.5, 5, 7.5 litre

Advertisement

Quick Links

INSTANT BOILING WATER DISPENSERS
INSTRUCTION MANUAL AND USER GUIDE
Models 2.5, 5, 7.5 Litre
This boiling unit must be installed and serviced by a qualified person.
Please leave this guide with the owner.
BROMIC Pty Ltd
10 Phiney Place, Ingleburn, NSW 2565 Australia
AU 1300 276 642 NZ 0508 276 642 plumbing@bromic.com bromicplumbing.com
V1.9 09/2024

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 2850205 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Bromic Heating 2850205

  • Page 1 INSTANT BOILING WATER DISPENSERS INSTRUCTION MANUAL AND USER GUIDE Models 2.5, 5, 7.5 Litre This boiling unit must be installed and serviced by a qualified person. Please leave this guide with the owner. BROMIC Pty Ltd 10 Phiney Place, Ingleburn, NSW 2565 Australia AU 1300 276 642 NZ 0508 276 642 plumbing@bromic.com bromicplumbing.com V1.9 09/2024...
  • Page 2 This page intentionally left blank. bromichotwater.com 1300 276 642...
  • Page 3: Table Of Contents

    CONTENTS PREFIX IMPORTANT NOTES AND WARNINGS PRODUCT SPECIFICATIONS 3.1 Specifications Table 3.2 Diagram: Dimensions 3.3 Dimension Table INSTALLATION 9-10 4.1 Heater Mounting and Water Connection 4.2 Electrical Connection OPERATION SERVICING TROUBLESHOOTING 13-14 7.1 Fault Finding Guide 7.2 Self Diagnostics WIRING DIAGRAM SPARE PARTS LIST WARRANTY What Do the Symbols Used Mean?
  • Page 4: Prefix

    1. PREFIX This manual contains important information about the installation, operating and maintenance of the Bromic Instant Boiling Water Dispensers. Please pay close attention to the important safety information shown throughout this instruction manual. Any safety information will be accompanied by the following safety alert symbols: DANGER, WARNING, IMPORTANT...
  • Page 5: Important Notes And Warnings

    2. IMPORTANT NOTES AND WARNINGS DANGER WARNING IMPORTANT • Read all instructions before installing or using this appliance. • Installation must be performed by a qualified technician and is subject to the requirements of the applicable regulatory authority, including compliance with AS/NZS 3500.4, Clause G12 of the NZ Building Code, the NCC VOL.
  • Page 6 • If the appliance is situated in an area where the ambient temperature can drop below 5°C when not in use, do not turn off the power. This measure does not protect the connecting pipes and fittings. • In areas with hard water where mineral scale build-up can occur, appropriate maintenance measures should be considered.
  • Page 7: Product Specifications

    3. PRODUCT SPECIFICATIONS 3.1 SPECIFICATIONS TABLE Bromic Instant Boiling Water Dispensers 2.5L 7.5L Part number 2850205 2850215 2850225 Storage Capacity (Litres) Max. Water Supply Pressure (kPa) Min. Water Supply Pressure (kPa) Cold Water Connection 1/2” BSP Overflow Vent Connection 1/2” BSP...
  • Page 8: Diagram: Dimensions

    3.2 DIAGRAM: DIMENSION SPECIFICATIONS FRONT VIEW SIDE VIEW 9.50 DETAIL A1 ENLARGED MOUNTING HOLE 3.3 DIMENSION SPECIFICATION TABLE DIMENSION (mm) Model 2.5L 7.5L bromichotwater.com 1300 276 642...
  • Page 9: Installation

    4. INSTALLATION WARNING DANGER • Installation must be performed by a qualified technician in compliance with AS/NZS 3500.4 Plumbing and drainage: Heated water service and Clause G12 of the NZ Building Code as well as all other current national and local regulations. •...
  • Page 10: Electrical Connection

    4.1.4 DRAINING Turn off the unit and open the tap until water stops flowing. Remove the unit from the wall and take off the cover. Locate the drainage screw at the bottom of the tank and unscrew it to completely drain the remaining water.
  • Page 11: Operation

    5. OPERATION TO TURN ON AND FILL THE BOILING WATER UNIT: Do not turn on the appliance until the outer cover has been correctly installed. • Switch on the mains water supply and then connect the appliance to the power source. Inspect all connections for any possible leaks and repair if necessary.
  • Page 12: Servicing

    6. SERVICING IMPORTANT! To ensure the optimal performance and longevity of your boiler unit, regular servicing is essential. The To ensure the optimal performance and longevity of your boiler unit, regular servicing is essential. The frequency of service depends on the quality of the water in your area. Do not perform any maintenance frequency of service depends on the quality of the water in your area.
  • Page 13: Troubleshooting

    7. TROUBLESHOOTING 7.1 FAULT FINDING GUIDE Symptom Possible Cause(s) Solution There is no power supply Check the electrical supply There is no water supply Check the water supply The filter is blocked Check the filter, clean or replace The unit does not fill with water Electronic Controller failure Test the Electronic Controller...
  • Page 14: Self Diagnostics

    7.2 SELF-DIAGNOSTICS This appliance is fitted with self diagnostics and indicative LED Lights. The self diagnostic features programmed into the PC-board enables the unit to determine if a component is faulty or if there is a fault in heating and/or filling modes i.e. no water connected. Diagnostic faults are indicated on the front LED’s of the face plate.
  • Page 15: Wiring Diagram

    8. WIRING DIAGRAM ON BOX 100μF/16V 100μF/16V 1000μF/35V 1300 276 642 bromichotwater.com...
  • Page 16: Spare Parts List

    9. SPARE PARTS LIST Part Description ELE-1,8 1.8KW ELEMENT(2.5L) ELE-2,0 2.0KW ELEMENT(5, 7.5L) PC BOARD VALVKIT SOLENOID VALVE KIT TAP-O/ASS OUTLET TAP ASSEMBLY WAT-PROBE WATER LEVEL PROBE THERMIS THERMISTORS SEALS TANK/ELEMENT SEAL TAP-SPAC TAP OUTLET SPACER TAP-H TAP HANDLE TAP-CAP TAP CAP TAP-SHAF TAP SHAFT...
  • Page 17: Warranty

    10. WARRANTY Read all instructions before installing or using this appliance. The Bromic Instant Boiling Water Dispenser Warranty for New Zealand and Australia covers both domestic, commercial, and industrial installations. The warranty includes repair or replacement of faulty components or, if necessary, the entire unit: All Components: Covered for 2 years from the date of installation, including parts and labor.
  • Page 18 NOTES bromichotwater.com 1300 276 642...