Advertisement

Human Machine Interface
The PW S 3261 is equipped with a 10.4" VGA (640Hx480V) L CD
D
display and analog resistive touch screen. The IP 65 (NEMA 4) rated
Introduction
f ront pan el seal and industrial grade touch screen make t he prod uct
rugged an d durable. There are three display options: color TFT LCD,
color DSTN LCD, a nd Mono FS TN LCD. You can choo se appropriate
one according to your application's need. Every P W S 3261 HMI
comes wit h a printer port th at allows you to print out inf ormation
about
upload/ download applications a nd source codes. W ith the supp ort of
USB, your de velopmen t and test cycle could b e speeded up as its
speed is more than twice as fa st a s the tradition al download/upload
via COM ports.
This chapter describes ho w to install your PW S to a panel, to set its
DIP switches, a nd t o make cables f or its communications an d p rinte r
ports.
D-1
The t hree-position po wer connecto r a ccepts 24V DC only. The unit's
Power Connector
power consumption is shown in th e f ollo wing:
Item / Model
Power
Consumption
Fuse Rating
Human Machine Interface
About PWS3261
your
applications.
PWS3261-STN
±
24VDC
10%
under 13W
1A
Hitech Electronics Corporation
4th Fl. No. 501-15 Chung-Cheng Rd.,
Shin-Tien, Taipei Shien, Taiwan
T el:8 86-2-22183600 Fa x: 886-2- 22183060
http://www.hitechsite.com.tw
Hitech Electronics Corp.
The
USB
port
allows
PWS3261-DTN
PWS3261-TFT
±
24VDC
10%
24VDC
under 18W
under 20W
1A
1A
About PWS3261
you
to
easily
±
10%
D-1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PWS3261 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hitech PWS3261

  • Page 1 Human Machine Interface About PWS3261 About PWS3261 The PW S 3261 is equipped with a 10.4" VGA (640Hx480V) L CD display and analog resistive touch screen. The IP 65 (NEMA 4) rated Introduction f ront pan el seal and industrial grade touch screen make t he prod uct rugged an d durable.
  • Page 2 PWS3261 hmi@hitech-lcd.com.tw Human Machine Interface...
  • Page 3 Human Machine Interface About PWS3261 Gen eral Specificatio n of PWS3261 Item PWS3261-FTN PWS3261-DTN PWS3261-TFT General Display Type Mono FSTN LCD Color DSTN LCD Color TFT LCD Specification Display Color 16 shades of grey 256 colors 256 colors Display Size 10.4"...
  • Page 4 PWS3261 Dimensions of PWS3261 Dimensions & Cutout Dimension Fixture mounting holes Power lamp Run lamp Display Human Machine Interface...
  • Page 5: Dip Switch

    Human Machine Interface About PWS3261 DIP SWITCH(1-10) Battery of PWS3261 DC power supply ETHERNET PORT 10 BASE-T USB PORT COM1: COM2: RJ-45 RS232C ; RS232C ; RS422 ; RS422 ; LPT port of RS485 RS485 PWS3261 Cut out th e mounting hole to match the d imensions shown below.
  • Page 6 PWS3261 W he n water o r liquid dripping could be a problem to the back of t he unit , please install the unit with an appropriate protection as shown in the picture. This will enable PW S to work properly and prolong its life.
  • Page 7 Human Machine Interface About PWS3261 the touch key. W hen you press a tou ch key, the PW S responds by sounding the buzze r f or 200 milli-seconds (def ault) and reve rsing the color of that tou ch key f o r 200 milli-second s. W ith the f eedback , you know the PW S has accepted your key-press.
  • Page 8 PWS3261 F i g u r e D-3 F i g ure D- 4 F i g ur e D- 5 You would not n eed to adjust th e calibration of TOUCH KEY, unless Calibrating TOUCH KEY is out of th e ca libration. To adjust the calibration of...
  • Page 9 Human Machine Interface About PWS3261 F igu re D-6: PW S3261 Calibr ating Touc h Panel Figur e D-7: PW S3261 Calibratin g Touch Panel Human Machine Interface Hitech Electronics Corp.
  • Page 10 PWS3261 D-5.1 You can adjust the contrast of the PW S3261-FTN and PW S3261-DTN LCD Contrast at any time your a pplication is running on t he PW S . You can calib ra te Adjustment the LCD contrast by pressing the "Calibrate" button on System Men u.
  • Page 11 Human Machine Interface About PWS3261 PWS3261 Setting o f DIP Switch es Setting of DIP SW 1 SW 2 Function on purpose Switches Via COM1 in Download BIOS mode. Via COM 2 in Dow nload BIOS mode. SW 3 SW 4 Runn ing M ode Runs us er applic at ion.
  • Page 12 A fter each test, t he PW S displays the result as shown in Self Test the f ollowing example. Industrial Workstation ROM BIOS Version 1.1 (C) 2000 Hitech Electronics Corporation Display Type ....TFT Color System RAM Size ....256K Bytes Video RAM Size ...... 1024K Bytes Battery Backed RAM Size .....
  • Page 13 Human Machine Interface About PWS3261 If you have never con f igured your PW S, the self -test may report a f ailure of the real time clock. If this happe ns, conf igure as described in section D.10 (Settin g Ope rating Paramete rs). If you have never downloaded an application to the PW S, the self-test may rep ort a problem in th e f lash chips.
  • Page 15 About PWS3261 Human Machine Interface After the user level is determined by a password or by the def ault, the PW S displays System Menu if the DIP switch No.7 is on; If DIP PWS3261 System Menu switch 7 is off , the PW S starts run ning your application immediately.
  • Page 16 PWS3261 Button Function User Level Starts running your application. Allows you to download an application to Download Application the PWS from a PC or another PWS. Allows you to download recipes to the PWS Download Recipes from a PC or another PWS.
  • Page 17 About PWS3261 Human Machine Interface To make the PW S ready fo r receiving downloaded application, press the Download Application but ton on System Menu. The PW S displays the message "Waiting fo r downloading...” when it Downloading Application is ready.
  • Page 18 PWS3261 to the PWS unit. D-16 Human Machine Interface...
  • Page 19 About PWS3261 Human Machine Interface You can use Communication Parameter dialog box of ADP to set the parameters fo r the communications between your PW S3261 D-10 and PLC. The parameters set in ADP is transmitted to the PW S Setting along with all other data when you download an app lication.
  • Page 20 PWS3261 Fi gure D-13: PW S3261 hardw are Comm unic atio n Param eter D-11 Both of the PW S3261 communication ports COM1 and COM2 are serial serial ports that supp ort RS-232, RS-422, and RS-485 operations. Communicatio The pin assignments of the se ports are listed in the following table: n Port COM1 &...
  • Page 21 About PWS3261 Human Machine Interface Output Select 18-25 Signal ground D-12 Almost all the new PCs are equippe d with USB ports. Some even USB Port only have USB ports and do not suppo rt serial ports anymore. PW S3261 series are equippe d with USB port tha t could replace serial ports fo r download/u pload app lications and source code s a PC and PW S3261.
  • Page 22 PWS3261 connecting the USB cable to the HMI unit. D-20 Human Machine Interface...
  • Page 23 Human Machine Interface About PWS3261 3. Hardware detection and USB driver installation 3-1. Connect PC to HMI with USB TYPE A-male cab le. See Figure D-1 5 Fi gure D-15: USB Cable fr om PC to HMI 3-2. Be sure switches 7 of HMI is “ON”; then turn on the power on both HMI a nd PC.
  • Page 24 PWS3261 Fi gure D-17: Start the search for new devic e driver Fi gure D-18: Wi ndow s searches f or a device dri ver Fi gure D-19: Speci fy a the fi le direc tory w here the device driver is stored.
  • Page 25 Human Machine Interface About PWS3261 Fi gure D-20: Wi ndow s sear ches for the dri ve as you specif y and begin to install Fi gure D-21: the USB dri ver is installe d D-13 The PW S3261 supports the download /uplo ad funct io n via USB p ort.
  • Page 26 PWS3261 1-2. Be sure DIP-SW No 7 is “ on ” then turn on the p ower on HMI an d p ress the ”USB Down lo ad” button on system me nu. The PW S3261 displays “waiting for Downlo ading” and is ready to receive a d ownlo ad.
  • Page 27 Human Machine Interface About PWS3261 3. Downloading “ Firmware and application” or “application” 3-1. If you ha ve alrea dy compiled yo ur application, then select “Download Firmware a nd a pplication” o r “Down lo ad a pplication” fro m the “application” men u. The d ownload operation will start immediately.
  • Page 28 PWS3261 Fi gure D-25: ADP is trying to establi sh a c onnectio n to the HMI via USB p ort. Fi gure D-26: ADP shows “Erasing fla sh memory …” Fi gure D-27: ADP displays the per centage of c ompl etion.
  • Page 29 Human Machine Interface About PWS3261 Fi gure D-28: HMI shows ”Erasing fla sh memor y…” Fi gure D-29: Progress status of Programm ing the HMI 4. Download completed The d iffere nt messages shown on PC and HMI when d ownload is successf ul.
  • Page 30 PWS3261 Fi gure D-31: HMI displays down load succ essful. If your OS is Windows 2000, it will popup a warning message box. It is normal and you could just ignore it but closing the box. 5. Error message In case of an erro r messa ge appear, please check you r USB setting or cable connection.
  • Page 31 Human Machine Interface About PWS3261 Fi gure D-33: The HMI show s commun icat ion time out The PW S3261 supports download/upload fun ction via USB port. You D-14 Upload ca n e asy to save applicatio n p rogram and source codes into PC or HMI...
  • Page 32 PWS3261 Fi gure D-34: the screen of “waiting fo r Uploadi ng” 2. To select “USB” on Transmission setup box From ADP, select “options” > “Transmissio n setup” to specify the computer ’s USB port f or the u ploading opera tion.
  • Page 33 Human Machine Interface About PWS3261 Fi gure D-35:”Upload Appli c ation” in “File ” menu of ADP Fi gure D-36: PC requested fo r fi le name and directory 4. Upload completed The d iff erent me ssage sh own o n PC and HMI whe n upload is successf ul.
  • Page 34 PWS3261 If your OS is Windows 2000, it will popup a warning message box. It is normal and you could just ignore it but closing the box. D-15 From your PC downlo ad the program ***.AP1/ ***.AP 2 to the HMI.
  • Page 35 Human Machine Interface About PWS3261 2. Upload source code 2 -1. The USB cable connect way, DIP SW setting an d USB transmission setup are same as previous. 2-2. Select “Download source… ” f rom “ File “ men u of ADP an d give file na me and directory.
  • Page 36 PWS3261 Th e PW S saves passwords in the Rea l Time Clock chip. A password D-17-1 must ha ve eight nu meric characters. W he n you crea te a password, Password you must specify the user level associative with th at password. Th e...
  • Page 37 Human Machine Interface About PWS3261 Figure D-43 : entering a password Figure D-44: Nume ric keys fo r pas sword table Human Machine Interface D-33 Hitech Electronics Corp.
  • Page 38: Package Contents

    PWS3261 Package Contents The following 2 items are included in the package. Before using, please make sure they are included. PWS unit ……. x 1 Installation screw nuts ……. x 8 Optional accessory Manual: English version order p/n 326118-01 Download Cable for PC COM1: order p/n WPC-p8-23...
  • Page 40 PWS3261 Cautions If this product is used in a house, radio-wave interference might occur to other devices. In the case that it does occur, the user is requested to try a variety of remedies to solve the problem. Power source PWS is equipped with DC24V input.

Table of Contents