Advertisement

Quick Links

supremeSchwank Series
Models: 2312; 2313; 2352
All models approved:
ANSI Z83.26-2014 / CSA 2.37-2014
Gas-Fired Infrared Patio Heater for Outdoor Commercial / Residential Application
ANSI Z83.19a-2011 / CSA 2.35a-2011
Gas-Fired High Intensity Infrared Heater for Commercial /Industrial Non-Residential
Application for either indoor or outdoor installation
All models constructed with Marine Grade Stainless Steel Cabinet
INSTALLATION / OWNER'S MANUAL
WARNING
SAFETY ALERT:
This heater must be installed and serviced only by a trained gas service technician. Failure to
comply could result in personal injury, death, fire and/or property damage.
Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other gas fired appliance.
Indoor Applications: The heater cannot be used indoors in a residence.
IF YOU SMELL GAS:
FIELD CONVERTIBILITY:
This appliance is field convertible to
LP gas [except 2352/IO-252: NG only].
Only use kit available from manufacturer.
Follow kit instructions and all local and
national codes.
Improper installation, adjustment, alteration, service or mainte-
nance can cause property damage, injury or death.
Read the installation and operating and maintenance instructions
thoroughly before installing or servicing this equipment.
Extinguish any open flame
Do not attempt to light this or any other appliance
Don't touch any electrical switch, or telephone
Immediately leave the area and call your gas supplier from a neighbor's phone
Follow any and all instruction from your gas supplier
If your gas supplier is not available, call the fire department
INSTALLER: PRESENT THIS MANUAL
Keep this manual in a secure place.
Record for future reference:
Model #:
Serial #:
IO-200 Series Models:
IO-212; IO-213; IO-252
TO THE END USER.
[located on heater rating label]
2300 / IO 210 Manual
IM110107
RD: SEPT 2021
R.L. 21A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the supremeSchwank Series and is the answer not in the manual?

Questions and answers

Summary of Contents for infrasave supremeSchwank Series

  • Page 1 Series IO-200 Series Models: Models: 2312; 2313; 2352 IO-212; IO-213; IO-252 All models approved: ANSI Z83.26-2014 / CSA 2.37-2014  Gas-Fired Infrared Patio Heater for Outdoor Commercial / Residential Application  ANSI Z83.19a-2011 / CSA 2.35a-2011  Gas-Fired High Intensity Infrared Heater for Commercial /Industrial Non-Residential ...
  • Page 2 NOTICE: The manufacturer reserves the right to make changes to equipment and specifications without obligation or notification. This publication, or parts thereof, may not be reproduced in any form, without prior written consent from the manufacturer Unauthorized use or distribution of this publication is strictly prohibited. Gas Outdoor Patio Heaters 216 Avenida Fabricante Suite 207 San Clemente, CA 92672 (760) 779-1352...
  • Page 3: Table Of Contents

    Models: 2312; 2313; 2352 / IO-212; IO-213; IO-252 Gas-fired Infrared Patio Heater for Outdoor Commercial / Residential Application, and Gas-Fired Luminous [High Intensity] Infrared Heater for Commercial / Industrial Non-Residential Application for either indoor or outdoor installation TABLE OF CONTENTS TOPIC PAGE NUMBER TOPIC...
  • Page 4: Important Information - Read First Important Warnings

    WARNING Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read and understand this installation and op- eration manual thoroughly prior to assembly, installation, operation or service to this appliance. This heater must be installed and serviced only by a trained gas service techni- cian.
  • Page 5: Heater Expansion

    WARNING Heater Expansion It is a normal condition that during heat-up and cool-down a radiant heater will expand and contract. Allowances for heater expansion must be made in the gas connection and heater suspension. Improp- er installation, alteration, or adjustment can result in property dam- age, injury or death.
  • Page 6: Outdoor Patio Installation

    WHEN INSTALLED AS AN OUTDOOR PATIO HEATER • See pages 9 - 10 for Indoor installation, and Ventilation Requirements page 19 • Also refer to “Outdoor” and “Indoor” definitions and requirements on page 11 Certain materials or items, when stored under the heater, will WARNING be subjected to radiant heat and could be seriously damaged.
  • Page 7 Figure 1: OUTDOOR - MINIMUM CLEARANCES [Indoor Clearances Page 10] NOTE: ANGLE MOUNT IS MAXIMUM 30° TO AVOID DAMAGE Table 1: OUTDOOR - MINIMUM CLEARANCES TO COMBUSTIBLES Horizontal 30° Angle Under Ends Application MODEL NO OUTDOOR 2312 / IO-212 - NG/LPG 5.5”...
  • Page 8 Table 2: SUGGESTED MOUNTING DISTANCES FOR COMFORT MODEL MODEL MODEL MOUNTING 2312 / IO 212 2313 / IO 213 2352 / IO 252 PARAMETERS *** 23,000 Btuh 35,000 Btuh 50,000/35,000 Btuh A - Mounting angle Horizontal Max. 30 Horizontal Max. 30 Horizontal Max.
  • Page 9: Indoor Installation

    WHEN INSTALLED INDOORS FOR COMFORT OR SPACE HEAT • Also refer to “Outdoor” definition and requirements on page 11 • And refer to Indoor Ventilation Requirements page 19 WARNING Clearance to Combustibles Location of flammable or explosive objects, liquids or vapors close to the heater may cause fire or explosion and result in property damage, injury or death.
  • Page 10 Figure 3: INDOOR - MOUNTING CLEARANCES [Outdoor Clearances Page 7] NOTE: ANGLE MOUNT IS MAXIMUM 30° TO AVOID DAMAGE Table 3: INDOOR - MINIMUM CLEARANCES TO COMBUSTIBLES Horizontal 30° Angle Under Ends Application MODEL NO INDOOR 2312 / IO-212 - NG/LPG 8”...
  • Page 11: Application

    1. APPLICATION: All models are approved to for heating of outdoor ANSI Z83.26-2014 / CSA 2.37-2014 commercial / industrial / residential patios and areas, and are also approved to ANSI Z83.19a-2011 / CSA for heating indoor and outdoor commercial / industrial / non-residential spaces. 2.35a-2011 It is beyond the scope of these instructions to consider all conditions that may be encountered.
  • Page 12: Aircraft Hangars

    INSTALLATION IN COMMERCIAL AIRCRAFT HANGARS Luminous [high intensity] radiant tube heaters are suitable for use in aircraft hangars when in- stalled in accordance with the latest edition of the Standard for Aircraft Hangars, ANSI/NFPA No 409 in the USA, or the Canadian Natural Gas and Propane Installation Code, B149.1. A.
  • Page 13: Installation Requirements

    IMPORTANT: For either horizontal or up to 30° angle mounting, the long axis of the heater must be level. Use only non-combustible mounting hardware. Figures 6 & 7 on Page 21 il- lustrate typical suspension hardware that may be used, and provided by Schwank/Infrasave as an optional component.
  • Page 14: Gas Supply Piping

    For outdoor installation the connector must be in compliance with ANSI Z21.75 / CSA 6.27. An optional 3/8” x 24” black finish flexible gas connector [part number JL-0771-OD - approved Indoor/Outdoor] is available from Schwank / InfraSave. •...
  • Page 15: Installation Procedures

    PROPER WIRING POLARITY MUST BE MAINTAINED, particularly when grouping the heat- ers in a zone. Total wiring distances of up to 200' must use minimum 16 gauge electrical wire, and wiring distances of over 200' must use minimum 14 gauge electrical wire. The heater must be electrically grounded in accordance with local and national electrical codes.
  • Page 16: Lighting Instructions

    10. LIGHTING INSTRUCTIONS 1. Ensure the correct voltage is supplied, gas supply lines have been properly purged, and gas valve is switched to the ON position. 2. Turn on power to heater, set thermostat [if applicable] to above ambient temperature, the heater will light.
  • Page 17: Servicing Guide

    12. SERVICING GUIDE [Also refer to Troubleshooting Guide on page 29] Servicing of heater is essential for continued efficient operation. Servicing should be carried out annually by a qualified gas service technician as follows: • Clean the ceramic tiles with compressed air. Avoid directing air stream at gasket material between tile and heater body.
  • Page 18 Figure 4: HEATER SERVICE POSITION WITH WALL MOUNT BRACKET [To simplify illustration the heater is not shown] 2300 / IO 210 Manual IM110107 RD: SEPT 2021 R.L. 21A...
  • Page 19: Ventilation For Indoor App's

    13. VENTILATION REQUIREMENTS FOR INDOOR APPLICATION WARNING Inadequate venting of a heater may result in asphyxiation, car- bon monoxide poisoning, injury or death. Heating system venting must be in accordance with all local, state, provincial, and national codes [ANSI Z223.1/ NFPA 54 in USA;...
  • Page 20: Mounting Kit Options

    14. HEATER DIMENSIONS & CONFIGURATIONS Table 5: CAPACITIES & CONFIGURATIONS MODEL Voltage Current Btu/hr input Total Length amps Weight [lbs]. < A > 2312 / IO 212 -NG 23,000 30 1/2” 2312 / IO 212 -LP 23,000 30 1/2” 2313 / IO 213 -NG 35,000 43 1/2”...
  • Page 21: Mounting Kit Options

    Figure 6: MOUNTING KIT OPTIONS NOTE: MOUNT HEATER AT MAXIMUM 30° ANGLE TO AVOID DAMAGE ITEM 1: UNIVERSAL ITEM 3: ARM WALL MOUNTING KIT JP-2300-MK MOUNTING KIT JP-2100-CB-K Also see next page ITEM 4: POST MOUNTING KIT ITEM 2: WALL MOUNTING KIT JP-2300-PK JP-2100-MB Figure 5: MOUNTING OPTIONS...
  • Page 22: Mounting Kit

    JP-2100-CB-K: UNIVERSAL MOUNTING KIT for Patio Heaters Figure 8: UNIVERSAL Component Quantities and Material Specifications each Kit: MOUNTING KIT 2 x Ceiling/Wall Bracket - 12 ga. [0.102”] 316 S/S 2 x 24” [610 MM] Channel Leg - 12 ga. [0.102”] 316 S/S 2 x Heater Attachment Bracket - 12 ga.
  • Page 23 Figure 10: HEATER INSTALLATION: JP–2100-MB : WALL MOUNTING KIT NOTE: MOUNT AT MAXIMUM 30° ANGLE TO AVOID DAMAGING HEATER USE BRACKET AS TEMPLATE FOR HOLES/BOLTS TO THE STRUCTURE. FASTEN WALL BRACKET TO FASTEN TO STRUCTURAL MEMBER[S] STRUCTURE USING FIELD SUP- OR DEVISE STRUCTURAL SUPPORT TO PLIED FASTENING HARDWARE.
  • Page 24 JP-2300-MK : ARM WALL MOUNTING KIT NOTE: MOUNT HEATER AT MAXIMUM 30° ANGLE Using pairs of holes in the heater bracket allows heater orientation: • Horizontal • Angled at 30° [MAXIMUM angle mount] Assemble Mounting Bracket to Mounting Arm using bolts and nuts supplied: •...
  • Page 25 JP-2300-PK POST MOUNTING KIT USE CARE NOT TO DAMAGE OR SCRATCH HEATER DURING INSTALLATION FASTEN THE TWO POLE CLAMPS TO STRUCTURE USING FIELD SUPPLIED FASTENING HARDWARE.ENSURE SUFFICIENT STRENGTH AND INTEGRITY TO CARRYY WEIGHT OF HEATER AND WIND/SNOW LOADS FASTEN HEATER BRACKET TO STUDS ON TOP OF HEATER INSTALL THE TWO POLE CLAMPS ON TO WALL BRACKET USING BOLTS...
  • Page 26: Electrical Requirements

    16. ELECTRICAL REQUIREMENTS AND THERMOSTAT CONTROL All electrical installations must meet local and the latest edition Electrical Code PART 1 CSA C22.1 in Canada and ANSI/NFPA N0 70 in the U.S.A.. Single heater requires 24 Volt, 60 Hz electrical transformer sized at 40VA. If multiple heaters are connected to a single transformer, the proper transformer is 24 Volt, 60 Hz, sized at 40VA for the first heater, and 20VA each for all subsequent additional heaters.
  • Page 27: Sequence Of Operation-Fenwal 35-60 Dsi

    17. SEQUENCE OF OPERATION FOR FENWAL 35-60 DSI CONTROL Start up - Heat Mode: On a call for heat the Fenwal 35-60 control will reset, perform a self check routine, flash the diagnostic LED for up to four seconds. The gas valve and spark are energized commencing the trial for ignition period.
  • Page 28: Spark Ignition Circuit

    Cautions: 1. The ceramic insulator of the igniter assembly should not be in or close to the flame. 2. The electrode assembly should not be disassembled and care must be used in making mi- nor gap adjustment. The spark electrode should have a gap spacing of 1/8”- 3/16” [3.12±...
  • Page 29: Wiring Diagram

    19. WIRING DIAGRAM: 2300 / IO 210 with Fenwal 35-60 DSI Control If installing remote control kit JP-1235-RK refer to wiring diagram in the remote control manual Fenwal Control Terminal Designation Error Mode LED Indication Internal Control Failure Steady on Thermostat / 24V Supply Input System Ground Flame with No Call for...
  • Page 30 19-B. WIRING DIAGRAM: 2352 / IO-252 Two-Stage: Fenwal 35-60 DSI 2300 / IO 210 Manual IM110107 RD: SEPT 2021 R.L. 21A...
  • Page 31 18-C. WIRING DIAGRAM: Two-Stage Switch Control 2300 / IO 210 Manual IM110107 RD: SEPT 2021 R.L. 21A...
  • Page 32: Troubleshooting Guide

    20. TROUBLESHOOTING GUIDE *CHECK 120 V AT PRIMARY TRANSFORMER TURN HEATER ON *CHECK VOLTAGE OUT AT SECONDARY. *IF THERE IS NOT 24V TO SECONDARY...REPLACE THE TRANSFORMER *CHECK 24V WIRING FROM TRANSFORMER 24 VOLTS ±10% TO DSI CONTROL TO IGNITION CONTROL / AND CHECK IF CORRECT GAUGE OF WIRE FOR DISTANCE.
  • Page 33 MAIN BURNER LIGHTS CHECK FOR CORRECT MANIFOLD GAS PRESSURE *CHECK FOR OBSTRUCTION IN GAS SUPPLY OR OR- IFICE [INSECTS, SPIDERS COCOONS ETC.] CHECK FLAME SIGNAL WITH METER FOR 0.7µA. IF READING IS LOW CHECK GAS PRESSURE, IF OK SPARK STOPS WHEN BURNER LIT.
  • Page 34: Commissioning Report

    21. COMMISSIONING REPORT This heater has been factory fired and tested prior to shipment. However, it is not a ’Plug-in’ appliance. Commissioning and field adjustment to correct settings is required. COMPLETE THIS COMMISSIONING REPORT AND FILE THIS MANUAL AT SITE FOR FUTURE REFERENCE INSTRUCT THE END USER THAT THIS MANUAL MUST BE KEPT SECURE A QUALIFIED SERVICE TECHNICIAN CALLING FOR TECHNICAL SUPPORT MUST PROVIDE THE INFORMATION FROM THE...
  • Page 35 HEATER COMMISSIONING TECHNICAL REPORT TO BE COMPLETED BY QUALIFIED GAS FITTER INSTALLER TYPE OF GAS HEATER IS EXPOSED TO CHENICAL OR CORROSIVE ATMOSPHERE OPEN COMBUSTION IS COMPATIBLE WITH THE INSTALLED LOCATION MINIMUM CLEARANCES CONFORM TO REQUIREMENTS OF THIS MANUAL WHAT IS THE ALTITUDE OF THIS PROJECT LOCATION ABOVE SEA LEVEL FEET IS ALTITUDE ADJUSTMENT REQUIRED? [See Section 21 next page] ...
  • Page 36: High Altitude Installation

    22. HIGH ALTITUDE INSTALLATION / DERATION This heater not to be installed at altitude above 6,800 feet. USA: The factory installed orifice for this appliance is approved for altitudes zero to 2000 feet above sea level. When installed above 2000 feet, refer to information below. Canada: The factory installed orifice for this appliance is approved for altitudes zero to 4500 feet above sea level.
  • Page 37: Replacement Parts List

    23. Replacement Parts List Replacement parts for the 2312 / IO-212 and 2313/ IO-213 2312 / IO-212 2313 / IO-213 STANDARD BLACK FINISH - ENCLOSURE PARTS ORDER QUANTITY PART NAME PART # PART # 1 PATIOSCHWANK SCREEN [316 SS] JP-2312-SS JP-2315-SS 2 PATIOSCHWANK TOP COVER S/S JP-S312-CV...
  • Page 38 Note: HI VOLTAGE WIRE - SPARK 2300 - JX-0228-YY 2312 / IO-212 2313 / IO-213 REPLACEMENT PARTS LIST ORDER QUANTITY PART NAME PART # PART # 8 BURNER ONLY - ECO 06-X JX-X025-BO 8 BURNER ONLY - ECO 10-X JX-X037-BO 9 GASKET SET - AGRO 315 JX-0245-AA 9 GASKET SET - ECO 10...
  • Page 39 REPLACEMENT PARTS LIST 2312 / IO-212 2313 / IO-213 ORDER QUAN- TITY PART NAME PART # PART # PATIOSCHWANK REFLECTOR LEFT [316 S/S] JP-S312-RS-L JP-S313-RS-L PATIOSCHWANK HORIZONTAL PLATE [316 S/S] JP-S312-HP JP-S313-HP PATIOSCHWANK 2300 IGNITER PLATE [304 S/S] JP-2300-IG JP-2300-IG PATIOSCHWANK 2300 SEPARATOR PLATE JP-2300-SP JP-2300-SP...
  • Page 40 23. Replacement Parts List Con’t Replacement parts for the 2352 / IO-252 2352 / IO-252 STANDARD BLACK FINISH - ENCLOSURE PARTS ORDER QUANTITY PART NAME PART # 37 PATIOSCHWANK 2313 / 2352 SCREEN [316 SS] JP-2315-SS 38 PATIOSCHWANK 2300 HANGING SUPPORT S/S JP-S300-HS 39 PATIOSCHWANK 2313 TOP COVER S/S JP-S313-CV...
  • Page 41 Note: HI VOLTAGE WIRE - SPARK 2300 - JX-0228-YY LEAD WIRE 15" - SENSOR FLAME - JA-0569-LW 2352 / IO-252 REPLACEMENT PARTS LIST ORDER QUANTITY PART NAME PART # 1 BURNER ONLY - ECO 13-X JX-X050-BO 2 GASKET SET - ECO 13 JX-0246-XX 6 TILE RETAINER END - ECO JR IL [ONE EACH END] Each...
  • Page 42 2352 / IO-252 REPLACEMENT PARTS LIST ORDER QUANTITY PART NAME PART # PATIOSCHWANK 2352 ACCESS IGNITER PLATE JP-2352-IG-A PATIOSCHWANK 2352 ACCESS VENTURI PLATE JP-2352-VP-A PATIOSCHWANK 2352 ACCESS VENTURI BRACKET JP-2352-VP-B PATIOSCHWANK 2315 HORIZONTAL PLATE [316 S/S] JP-S315-HP PILOT - IGNITER & SENSOR BRACKET FOR - Q3451B JX-0205-BK-B HW IGNITER PILOT BURNER ASSEMBLY c/w SPARK WIRE &...
  • Page 43: Limited Warranty Certificate

    This warranty gives you specific legal rights. You may also have other rights which vary by jurisdiction. Gas Outdoor Patio Heaters 216 Avenida Fabricante Suite 207 San Clemente, CA 92672 (760) 779-1352 www.GasOutdoorPatioHeaters.com www.InfraSave.com 2300 / IO 210 Manual IM110107 RD: SEPT 2021 R.L. 21A...

Table of Contents