OPERATING INSTRUCTIONS (cont'd)
INSTALLING PVC
DRAIN HOSE
CONTINUOUS
DRAIN
The function of continuous drain can be performed using the following steps:
1) To save having to periodically empty the water tank, this unit can
be configured for continuous drain. You can use the supplied
drain hose to connect to the continuous drain connector.
2) Unscrew and remove the drain cover at the rear of the unit (Fig.
A).
3) Remove the soft rubber stopper, and place it in the water tank for
safe keeping (Fig. B).
4) Insert the drain hose through the hole of the drain cover (Fig. C).
5) Ensure the rubber seal ring is properly seated in the end of the
hose as shown in Fig. C.
6) Connect the drain hose to the drain port (Fig. D).
7) Tighten the drain cover in clockwise direction onto the rear of
the unit (Fig. D).
8) Place the bucket in its original location (Fig. E).
When using the continuous drain function, the PVC hose must be placed horizontally
below the drainage hole. Avoid uneven ground and folding the hose.
NOTE: Should you damage or misplace the pvc drain hose, a standard garden hose
can be used.
Drain hose
Drain cover
Drain hose
Drain hose
7
Back of the unit
Fig. A
Drain cover
Fig. B
Soft rubber
stopper
Drain cover
Fig. C
Fig. D
Drain cover
Drain hose
Fig. E
Bucket