User_Manual P664 - PROFINET/PROFIsafe V85 Directories Status: released Revision history Date Editor Change 26.06.19 Frank Eggensperger Created 02.01.20 Jakob Gegeniger Output current for digital outputs corrected 22.04.21 Jakob Gegeniger Removing of the 24-hour-operation-warning (§4.6) P664_00_3094_User_Manual_PN.docm (22.04.21 / Rev 1.2) page 2 of 14...
Page 3
User_Manual P664 - PROFINET/PROFIsafe V85 Directories Status: released Table of contents Introduktion Further documents Hardware Setup of the PLC project GSDML File ..............................8 Device module ............................8 PROFINET device ............................9 PROFIsafe device ............................10 Modules ..............................11 User data ..............................11 Commissioning P664_00_3094_User_Manual_PN.docm...
Figure 5:Left side: Presentation of the PROFIsafe device in PLC project, right side: part of the module catalogue . 10 Figure 6: data structure example for PROFIsafe-module ..................12 Figure 7: Status LEDs at the V85 device ........................14 List of tables Table 1: Technical Values .............................
Page 5
To ensure the security of the system, the configuration options for customers and the internal configuration options are treated differently. The devices can be operated as PROFINET and as PROFIsafe device. But only the manufacturer W. Gessmann can define the PROFINET or PROFIsafe operation of each module.
Status: released 2 Further documents For the configuration and commissioning of a specific PROFINET / PROFIsafe V85 device, the following documents which are supplied with the device must be followed: 1. Wiring diagram The individual device is described by the wiring diagram. References to further documents may be given here.
User_Manual P664 - PROFINET/PROFIsafe V85 3 Hardware Status: released 3 Hardware The following table gives the technical values of the device. The information on the wiring diagram may differ and applies overrulingly. Table 1: Technical Values Characteristics Value Note Power supply +12 V …...
User_Manual P664 - PROFINET/PROFIsafe V85 4 Setup of the PLC project Status: released 4 Setup of the PLC project During the setup and integrating of the devices into the existing system, a number of essential points must be taken into consideration, which are explained in the following sections.
User_Manual P664 - PROFINET/PROFIsafe V85 4 Setup of the PLC project Status: released Figure 3: Data structure 4.3 PROFINET device The modules in the project configuration must be set according to the device documentation (see section above). The modules are summarized in the configuration system under the heading "PN-IO".
PROFIsafe modules according to 2.6.1 are omitted so that older systems can accept them as well. For setting the F-destination or F-source address of the PROFIsafe device, the software "PN-Device-Configurator" of W. Gessmann GmbH must be used. The program is available for download at the following link. URL: http://dl.gessmann.com/gessmann_400...
P664 - PROFINET/PROFIsafe V85 4 Setup of the PLC project Status: released 4.5 Modules There are four different module types, which can be used on the V85 device. These are shown in the following table. Table 2: module types Module meaning...
User_Manual P664 - PROFINET/PROFIsafe V85 4 Setup of the PLC project Status: released The assignment of the analogue signals and digital signals and the error information depends on the frame specified in the GSDML file (order, maximum of bit width, total length). The concrete assignment is defined in the wiring diagram.
5 Commissioning During commissioning of the V85 PROFINET / PROFIsafe device, there are no special features compared to other PROFINET devices. However, a brief check of the status LEDs is recommended. The following table explain the status LEDs. These LEDs can be used to determine the device status.