Adjusting the Program Settings in 5/2 Day Mode UFH10-RF - 10 x Under oor Heating Zones - CDT2-RF, RDT-RF & HDT-RF Menu Function UFH10-RF - 8 x Under oor Heating Zones, 1 Radiator Zone & 1 Hot Water Zone - RFRB , RFR & WRP...
How your Under oor Wiring Centre works Factory Default Settings The UFH10-RF is designed to manage & control the distribution of heat throughout the di erent Heat Enable: Volt Free Contacts Pump Delay: 00:00 Anti Seize: zones of your under oor heating system. The wiring centre provides a centralised point for...
Wiring Centre Terminals 1. Remove the UFH10-RF from its packaging. Power Supply UFH Valve (Under oor Heating Valve) 2. The UFH10-RF can be directly mounted on L 230Vac Live GR Grey Switch Live a wall using the xing holes on the base...
[10] Displays current mode. Hand Wheel [11] Displays when calling for heat. [12] Displays target temperature. [13] Displays zone title. [7] [8] Menu Test Button Button Program Time MENU TEST [10] Button Button PROG TIME [11] [13] [12] EPH Controls Ltd.
P3 ON time. Press ‘OFF’ will appear solid on the screen. to set the P3 OFF time. Press to con rm. Programming for Saturday and Sunday is now selected. Press to return to normal operation. MENU EPH Controls Ltd.
Press , ‘P01 rF COn’ will appear on the screen. MENU This function allows the user to connect an RF thermostat to the UFH10-RF. ‘P1 On’ will appear solid on the screen. Press , ‘RF CONNECT’ will appear solid on the screen.
To connect a HDT-RF to a UFH10-RF P02 Connecting your GW04 Gateway GW04 Gateway RDT-RF HDT-RF This function allows the user to connect the GW04 Gateway to the UFH10-RF. On the UFH10-RF: On the UFH10-RF: On the UFH10-RF: Press , ‘P01 rF COn’ will appear on the screen.
You can now scroll to another zone and hide it if required. Press to return to the menu. Press to con rm. Press to return to the menu. MENU MENU Press to return to the menu. MENU UFH10-RF...
P08 PIN P09 Holiday Function This function allows the user to put a PIN lock on the UFH10-RF. To Unlock the PIN This function allows the user to switch o their under oor heating by de ning a To Activate the PIN: Press , ‘UNLOCK’...
On the RF thermostat press and hold the until the screen displays ‘P01 & rF COn’ will appear on the screen. Frost protection is built into the UFH10-RF, it is pre xed at 5°C and is not ‘nOr & P01’. Rotate clockwise until ‘P12’...
Test Function Copy Function This function allows the user to activate a zone directly from the UFH10-RF Note: 7 day mode must be selected. See P03 setting the time and date To Copy a day schedule to other days within a zone.
Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 Zone 9 Zone 10 UFH10-RF - 10 x Under oor Heating Zones c/w RF Non-Programmable Thermostats. Options: RFRB ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5...
Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 Zone 9 Zone 10 UFH10-RF - 9 x Under oor Heating Zones - 1 x Hot Water Zone c/w RF Non-Programmable Thermostats. Options: ZONE 1 ZONE 2 ZONE 3 ZONE 4...
Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 Zone 9 Zone 10 UFH10-RF - 10 x Under oor Heating Zones c/w 230V RF Non-Programmable Thermostats. Options: CDT2-RF RDT-RF HDT-RF ZONE 9 ZONE 10 ZONE 1...
Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 Zone 9 UFH10-RF - 8 x Under oor Heating Zones - 1 x Radiator Zone - 1 x Hot Water Zone c/w RF Non- Programmable Thermostats & Hardwired Cylinder Thermostat. Options:...