Download Print this page

IKEUCHI CERJET BIM with SPB-adaptor Series Instruction Manual

Advertisement

Quick Links

C E R J E T ®
H. Ikeuchi &
Co., Ltd.
1. Suggestions & Cautions
2. Components of Nozzle
3. Disassembly
4. Cleaning
5. Assembly
6. Maintenance
7. Troubleshooting
8. Disposal
9. Inquiries
Instruction Manual for
BIM series with SPB-adaptor
BIM series with SNB-adaptor
Preface
Safety Precautions
NKS1167-6E
P. 1
P. 1
P. 2
P. 5
P. 6
P. 7
P. 7
P. 7
P. 8
P. 9
P. 9
H. Ikeuchi & Co., Ltd.

Advertisement

loading
Need help?

Need help?

Do you have a question about the CERJET BIM with SPB-adaptor Series and is the answer not in the manual?

Questions and answers

Summary of Contents for IKEUCHI CERJET BIM with SPB-adaptor Series

  • Page 1 P. 2 2. Components of Nozzle P. 5 3. Disassembly P. 6 4. Cleaning P. 7 5. Assembly P. 7 6. Maintenance P. 7 7. Troubleshooting P. 8 8. Disposal P. 9 9. Inquiries P. 9 H. Ikeuchi & Co., Ltd.
  • Page 2 H. Ikeuchi & Co., Ltd. Preface Thank you for purchasing the Spray Nozzle from H. Ikeuchi & Co., Ltd. This manual gives detailed instructions for the basic handling, maintenance and cautions of the product. Please be aware that due to continuing efforts to improve our products, some details in this manual may differ from the actual product.
  • Page 3 Set the siphon height to 500 mm or less. If the siphon height is more than 500 mm, irregular and intermittent spray may be caused. (b) Stop the liquid supply when not spraying for a long time. H. Ikeuchi & Co., Ltd.
  • Page 4 Only stopping the pilot air will not purge air from the pipe and thus will not lower the pressure enough to stop the spraying. To prevent this, use a 3-way solenoid valve for the pilot air pipe. Pilot air Liquid Compressed air Compressed Fig. 1 Piping example using 3-way solenoid valve H. Ikeuchi & Co., Ltd.
  • Page 5 If the pressure loss is too high due to the 3-way solenoid valve, use two 2-way solenoid valves with larger orifice diameters instead as shown below. Liquid Compressed air Fig. 2 Piping example using 3-way solenoid valve Liquid Compressed air Fig. 3 Piping example using two 2-way solenoid valves H. Ikeuchi & Co., Ltd.
  • Page 6 (2) Dimensions and materials may differ depending on part number of the nozzle. (3) In our material code, "S" represents "stainless steel". For example, S303 stands for stainless steel 303. H. Ikeuchi & Co., Ltd.
  • Page 7 (2) Nozzle adaptor (#4) is thin and fragile. To disassemble, first LOOSEN but DO NOT REMOVE the cap (#3), and remove the nozzle adaptor (#4) with a hexagon socket wrench. DO NOT use a spanner to remove the nozzle adaptor (#4). H. Ikeuchi & Co., Ltd.
  • Page 8: Maintenance

    Visually check the spray pattern. Appearance Confirm that there is no corrosion or dust adhesion to the nozzle tip and orifice. Periodically Connection Confirm that the cap, nozzle adaptor, connector, adaptor, and spring cap are tightened properly. H. Ikeuchi & Co., Ltd.
  • Page 9: Troubleshooting

    ・ Nozzle tip is deformed. ・ Replace the deformed part. Irregular ・ Nozzle tip is corroded. ・ Replace the corroded part. spray pattern ・ Dust or foreign particles adhered on ・ Clean the part. the orifices. H. Ikeuchi & Co., Ltd.
  • Page 10 Disposal should be practiced according to the regulations and codes of local authorities, or ask a disposal professional. 9. Inquiries For spare parts or any trouble, contact your supplier or the following: H. IKEUCHI & CO., LTD. Daiichi Kyogyo Bldg., 1-15-15, Awaza, Nishi-ku, Osaka 550-0011 JAPAN Tel: +81-6-6538-4015 Fax: +81-6-6538-4022 Email: overseas@kirinoikeuchi.co.jp...

This manual is also suitable for:

Cerjet bim with snb-adaptor series