Do you have a question about the U-P48200-7 and is the answer not in the manual?
Questions and answers
Summary of Contents for UFO Power U-P48200-7
Page 1
Wall Mounted Household Energy LiFe PO4 Storage Series User Manual V1. 1...
Page 2
PREFACE Summary: This document mainly introduces the product introduction, application sce nario, installation, commissioning, system maintenance and technical data of wall mounted household energy storage battery and battery expansion module. Reader object: This document is mainly applicable to the following Engineers: ◆...
1.Safety precautions 1 . 1 General security Statement When installing, operating and maintaining the equipment, please read this manual first and follow the signs on the equipment and all safety precautions . The “ notice", "attention", "warning " and "danger" in the manual do not represent all safety precautions to be observed, but only supplement all safety precautions.
◆ When installing the equipment, use tools to tighten the screws. ◆ Paint scratches during equipment transportation and installation must be repaired in time. It is strictly prohibited to expose the scratched parts to the outdoor environment for a long time. ◆...
◆ Do not stand or lean on or s it on the equipment. ◆ Do not damage each module of the equipment. ◆ When installing the battery module, if the battery module falls or is strongly impacted, the equipment will be damaged. It is strictly prohibited to continue to use, otherwise there will be safety risks (cell leakage, elec tric shock injury, etc.).
1.2 Personnel requirements ◆ The personnel responsible for the installation and maintenance of this equipment must understand various safety precautions and master the correct operation methods. ◆ Only qualified professionals or trained personnel are allowed to install, operate and maintain the equipment. ◆...
◆ If the equipment has multiple inputs, all inputs of the equipment shall be disconnected, and the equipment can be operated only after the equipment is completely powered off. Wiring requirements ◆ The use of the cable in high temperature environment may cause aging and damage of the insulating layer.
The installation methods of products are consistent. The operation modes of LCD and HMI are different. See screen operation for details 2.2 Appearance description LCD screen 9 111315 10 12 16 Description Functional Description Display battery status information( Four keys) Display the battery’s capacity( Four lights) Electricity volume indicator ALM alarm indicator light blinking...
Page 10
HMI screen 8 101214 11 15 Description Functional Description Display battery status information ALM alarm indicator light blinking Run indicator light blinking Positive terminal Battery+ Nagetive terminal Battery- Handling Handle Expand Bluetooth / Wi Fi / GSM functions External interface On/OFF button Reset key Display connection address...
Page 11
PPOWER R S 4 8 5 R S 4 8 5 E S I R S 2 3 2 R S T A D S R S 4 8 5 C A N M C B A L M R U N 4 5 6 7 89 11 13 14 15 10 12...
2. 3 System diagram (A) PV module ( B) DC switch ( C) Inverter ( D) AC switch ( E) Power Distribution Box ( H) Battery(WALL) ( F) Intelligent power collector (G) Power grid ( K) Router ( I) GSM (J) WIFI ( N) Load ( M) APP...
3. Product installation 3. 1 Unpacking inspection Please confirm whether the outer package of the product is damaged before unpacking. After unpacking, please carefully check the product for d amage or lack of accessories. In case of damage or lack of accessories, please contact the supplier directly for assistance.
Page 14
◆ The installation position s hall be away from the fire source. ◆ The installation position is not accessible to children. ◆ The installation position s hall be far away from water sources, such as faucets, sewer pipes, sprinklers, etc., to avoid water infiltration. ◆...
3 . 3 Ladder use safety ◆ Wooden ladder or FRP ladder s hall be used when power climbing operation may be involved. ◆ When using the herringbone ladder, the pulling rope must be firm, and someone must hold the ladder during operation. ◆...
◆ Lock the nut and fix the battery mounting bracket. Then hang the battery on the mounting bracket. ◆ After adjusting the position of the battery, lock the M6 * 40 screw at the top of the support, fix the battery, and place the battery to slide. ◆...
Cable Length Description Terminal diameter Used for connection between Anderson/SC25 -8 25mm² 1 - 3m battery and inverter For battery parallel connection Anderson 25mm² 1 - 3m 4.2 Communication line connection 4 . 2 . 1 RJ4 5 Communication point definition( 8 P 8 C ) 1 2 3 4 5 6 7 8 RS485 RS485_ B...
Page 18
Ex p la n a t i on ◆ RS232 communication: BMS can communicate with the computer through RS232 interface to check battery health related information including battery voltage, current, temperature, and manufacturer ’s default data. ◆ RS485 / can communication: CAN communication connects the battery with the inverter to function as duo for operations.
◆ Different inverter communication protocols have different pin definitions. Please pay attention to the compatibility between the battery and inverter RS485 / can communication line. 4. 3 System connection diagram I N V E R T E R B A T T E R Y PV combine r box AC _OUT AC _I N...
Description Description Cable color Cable color RJ45 Communication Line DC positive wire RS485/CAN communication DC negative wire R J 1 1 C o m m u n i cat io n L ine 4.4.2 Multiple batteries in parallel When the maximum continuous output power of the inverter is less than 6kW, the connection mode is as follows: Battery- 1 wireless kit...
Page 21
Multiple Inverters: b a t t e r y - 1 b a t t e r y - 8 b a t t e r y - 6 b a t t e r y - 1 5 w i r el e s sk i t R S TA D S D O R S 4 8 5 C A N R S 2 3 2 R S 4 8 5 w i r el e s sk i t...
◆ The inverter only needs to communicate with the host (Pack 1). ◆ When multiple batteries are connected with multiple inverters, it is best to connect through the combine r box. If it is not connected through the combine r box, the wiring mode s hall be confirmed with the manufacturer 's agent.
5.2 Battery function description 5.2. 1 Screen LCD screen composition MENU ENTER D O W N The operation steps are as follows: ◆ View battery information. 》 A n a l o g I n fo 》 》 P A C K V : 4 8 .
Page 24
◆ View product BMS protection times information. 》 A n a l o g I n f o 》 - - B M S S t a t u s 》 - - P a r a S e t t i n g 》 - - Sys Setting 》...
Page 25
Home: Description ICON 0% <SOC<25% 25% = SOC<50% 50% = SOC<75% 75% = SOC = 100% SOC =0% Battery Alarm Status Battery Information: Description Description Items Items Battery Pack Address Env Temp Environment temperature Addr. Remnant capacity Rem Cap MOS Temp MOS Temperature To l Cap Total capacity...
Battery Information: Alarm Status Description Description Items Items Discharge over current alarm MOS High temperature alarm MOS OT Low environment temperature Charge over current alarm alarm High environment temperature Total over discharge alarm alarm Discharge low temperature Total over charge alarm alarm Cell over discharge alarm Charge low temperature alarm...
Explanation After the BMS is reset, it still retains the parameters and functions set by the upper computer. If it needs to be restored to the initial parameters, it can be realized through the "restore default value" of the upper computer, but the relevant operation records and stored data remain unchanged (such as power, cycle times, protection records, etc.).
Explanation The LED indicator alarm can be enabled or disabled by the upper computer. It is enabled by default. HMI Screen: There are 2LEDS on front panel to show the battery working status. Normal/Alarm/ Protection PACK Status Remark Sleep Power Off All off Standby state Normal...
N o t i c e Before entering sleep, ensure that the input terminal is not connected to the external voltage, otherwise it will not be able to enter the low power consumption mode. Wake up: When the system is in the low power consumption mode and meets any of the following conditions, the system will exit the low power consumption mode and enter the normal operation mode: ◆...
Page 30
App interface description and operation steps User registration Switch to n MEμ in the lower right corner of APP. ◆ Click the avatar position to register. 令 “ Language ”for language switching, supporting 3 languages. Add device Click " home" in the lower left corner of the app to switch to the add product module. ◆...
Page 31
Alarm ◆ You can view battery alarm related information. D e s c r i p t i o n D e s c r i p t i o n It ems It ems D i s c h a r g e o v e r c u r r e n t a l a r m M O S H i g h t e m p e r a t u r e a l a r m D O C M O S O T...
6. Battery Monitoring 6. 1 Software running environment The software runs on PC and it is compatible to use Windows operating system. The system environment requires the support of Microsoft . Net Framework version 2.0 or above. Please confirm that it has been installed before use. The installation is as follows: ◆...
◆ Poor communication line or wrong wiring: Method: replace the communication line or correct the wrong wiring. ◆ The computer USB interface is not recognized: Method: change a USB interface ◆ Drive not installed: Method: install the driver corresponding to the communication line. Method for judging whether the communication line driver has bee n installed: ◆...
Page 34
Description Item Try to connect: search for available serial ports and open the m. Try connect The data key, which is the package serial number, displays the package being read and presented on the current interface with white words on a blue background ; Pack serial “Auto"...
◆ Get administrator privileges: Enter the administrator password in the "administrator password " input box at the bottom right of the interface. After correctly entering the password, the input box turns green. At this time, you have obtained administrator permission. 6.3.2 Parallel monitoring ◆...
Pause / continue: when reading, click " pause" to read, and then click again to continue reading. Save record: save the record on the interface to local. Delete record: delete the storage record of BMS board. Explanation when reading, the prompt "no more data" indicates that the reading has been completed.
Write parameters: overwrite BMS parameters. This operation requires administrator privileges. Restore default parameters: restore all parameters to the default parameters. The default parameters are from the preset parameters in BMS. This operation requires administrator privileges. Import parameters: read the data in the local file into this interface. Note: the data is only read on the interface and has not been written into the BMS.
6.4 Replacing inverter protocol on battery monitoring(Optional) Software running environment This function can only be realized by installing the protocol conversion board. Before using this function, please confirm whether the protocol conversion board is installed on this battery. This software does not need to be installed independently, but only needs to meet the environment.
7. Maintenance and replacement ◆ Please maintain the equipment when you are familiar with and understand the contents of this manual and have appropriate tools and test devices. ◆ Before carrying out maintenance work , please power down the equipment first, then follow the instructions of the delayed discharge label and wait for the corresponding time to ensure that the equipment has been powered down before operating the equipment.
◆ Battery maintenance shall be performed or supervised by personnel familiar with the battery and its required precautions. ◆ After the battery production test is completed, it needs to be supplemented to 3 0 - 5 0 % SOC at least before storage. 9.Warranty products Requirement: During the warranty period, the company requires customers to provide invoices and...
Need help?
Do you have a question about the U-P48200-7 and is the answer not in the manual?
Questions and answers