C10RS - TECHNICAL MANUAL - 0900B0696 FOREWORD FOR THE INSTALLER: Comply strictly with current standards governing the installation of electrical systems and security systems, and with the manufacturer’s directions given in the manuals supplied with the products. Provide the user with full information on using the system installed and on its limitations, pointing out that there are different levels of security performance that will need to suit the user’s requirements within the constraints of the specifi c applicable standards.
0900B0696 - TECHNICAL MANUAL - C10RS 1. GENERAL FEATURES C10RS is a small size, high quality power supply unit (PSU) for intrusion detection systems that mounts the high energy efficiency AL50LRS14V5 switching A/D converter. The microprocessor board, placed on the inside of the lid, will let you connect the PSU to all compatible EL.MO. control units over the Ultrabus RS-485 serial line thanks to its technologically advanced control and serial interface circuitry.
C10RS - TECHNICAL MANUAL - 0900B0696 2. TECHNICAL SPECIFICATIONS Model: C10RS Certification: IMQ-Alarm EN 50131-6 grade 2, environmental class II Mains power supply: AC 230 V, 50 Hz +10%-15% Mains current draw: 0.51 A with a 3 A load. Power: 51.8 W (0.45 power factor)
0900B0696 - TECHNICAL MANUAL - C10RS 3. MEASUREMENTS ► Distance between fixing holes ▼ External dimensions All measurements in mm 4. VIEW OF THE INTERNAL PARTS 1. Entry hole for the mains cable 5. AL50LRS14V5 switching A/D converter 2. Entry holes for all other cables 6.
C10RS - TECHNICAL MANUAL - 0900B0696 5. INSTALLATION Before installing the PSU, familiarize yourself with the standards regarding the installation of intrusion detection system and low voltage devices applicable in your country. Power down the mains cable before installing the control unit.
0900B0696 - TECHNICAL MANUAL - C10RS 7. WIRING 7.1 Stand-alone mode Battery anomaly Fault relay Self-powered siren battery recharge Mains failure Output not usable Unused inputs Power supply to the load Reset To backup battery Cable with JST connector from the A/D converter FUNCTION SELECTORS ATTENTION: the selector is actually rotated by 180°...
C10RS - TECHNICAL MANUAL - 0900B0696 7.2 RS-485 mode Alarm relay Follows the control unit output chosen in the programming browser (Serial devices / Ultrabus peripherals > Parameter) (Only works with DIP 2 set to OFF) Tamper alarm relay Self-powered siren battery recharge...
Page 9
0900B0696 - TECHNICAL MANUAL - C10RS Connect the PSU to any point of the serial line. Wire the cable shields of the two sections of the line together. Every PSU on the serial line has to have a different address.
C10RS - TECHNICAL MANUAL - 0900B0696 8. LED MEANING 8.1 Stand-alone mode Fault LED (left): Fast blink Slow blink 1 blink 2 blinks 3 blinks Overvoltage at Overvoltage at control Batter polarity inversion Very low F1 fuse LOAD terminal module input...
9. BATTERY DISCONNECTION AND RE-ARM Batteries can be severely damaged by over-discharge. For this reason, C10RS has a disconnection circuit that stops drawing power from its backup battery once it reaches the “very low battery” threshold (less than 9 V provided).