Page 1
The instruction manual is an integral part of the product Pellet stoves with MULTIFUOCO OPERATING INSTRUCTIONS FIRMWARE FWS03 - H09901200...
Page 2
TRONIC FORMAT on our company website (www.piazzetta.it), under “Products”, on the specific product characteristics page. This document is the property of Gruppo Piazzetta S.r.l. and no part of it may be reproduced or disclosed to third parties, wholly or in part, without written permission All rights reserved by Gruppo Piazzetta S.r.l..
OPERATING INSTRUCTIONS CONTENTS GENERAL INFORMATION FUEL REMOTE CONTROL Remote control functions Changing the batteries of the remote control unit APPLIANCE CONTROL PANEL 6 key control panel functions Setting the language BEFORE STARTING-UP THE APPLIANCE Information regarding the first start-up Check network voltage and frequency Fill auger STARTING THE APPLIANCE CHANGE THE POWER...
T.A.C. (authorized technical assistance centre). In the event of fire in the flue, stop using the - Gruppo Piazzetta S.r.l. cannot be held liable for situations of appliance, do not open the door of the ap- risk, defects, damage, product malfunctioning or for damage...
Page 5
OPERATING INSTRUCTIONS Product use may cause some surfaces to be- It is forbidden any unauthorized modification come extremely hot (the glass, the external of the appliance. surfaces, the handles, the smoke outlet pas- sage). Any contact between clothing or body parts and these surfaces, including where ac- Do not stand or place objects which are not cidental, may cause burns or fires.
OPERATING INSTRUCTIONS Before carrying out any assembly, installation or ignition proce- FUEL dures, the enabled installer must check that the system has been manufactured in compliance with the applicable instructions provided by the manufacturer and in compliance with all relevant regulations.
OPERATING INSTRUCTIONS REMOTE CONTROL APPLIANCE CONTROL PANEL The product is equipped with a panel on the appliance itself which allows the user to control the various functions. Only some of the functions can be controlled using the remote control. The optional remote control is only available upon re- The appliance is set with Italian as the default lan- ■...
OPERATING INSTRUCTIONS Keypad lock Before proceeding with start-up: To lock the buttons, press and hold (for approximately 10 the residual pellets in the grate must be removed ■ ■ seconds) until you see the message LOCK KEYBOARD. check that the grate is positioned correctly in its seat ■...
OPERATING INSTRUCTIONS The first start-ups must be done so as to allow the appliance body To carry out the FILL AUGER function: to settle and the paints, greases or oily fluids used during produc- - press for a few seconds tion to evaporate completely.
OPERATING INSTRUCTIONS CHANGE THE POWER CHANGE THE VENTILATION To change the power: Appliance with only one fan - press The speed of the hot air extractor fan installed as standard is mod- - F + ulated automatically based on the power. For safety reasons, it - select the required value using cannot be modified by the user.
OPERATING INSTRUCTIONS 11 PARTICULAR SITUATIONS 25° SHUT DOWN 11.1 RESTARTING DURING THE SHUT DOWN PHASE EMPTY GRATE AND PRESS ON-OFF The appliance will have finished the shut-down phase and the message "OFF" will have appeared on the display or it will still be in the shut-down phase and the message "SHUT DOWN"...
OPERATING INSTRUCTIONS 12 MENU 12.1 MAIN MENU FUNCTIONS For models with MULTIFUOCO SYSTEM. CHRONO ( 3 sec. ) ENG LANGUAGE LANGUAGE FRA LANGUAGE DEU LANGUAGE NED LANGUAGE POR LANGUAGE ESP LANGUAGE SWE LANGUAGE ITA LANGUAGE MO DAY...
OPERATING INSTRUCTIONS 12.2 ACCESS MENU KEYS ( 3 sec. ) To use the programming: - F + CLOCK - press for at least 3 seconds to enter appliance program- ming - F + - scroll through the main menu displayed using - T + - press to confirm the function to be programmed...
Page 14
OPERATING INSTRUCTIONS from 06.00 to 08.30 and from 16:00 to 20:00 only on Friday and Sat- ( 3 sec. ) urday - enable program PR4 from 06.00 to 08.30 on the days FR, SA - F + CHRONO - enable program PR5 from 16.00 to 20.00 on the days FR, SA from 08.00 to 13.00 only on Sunday <...
OPERATING INSTRUCTIONS START - OFF If the START function is set to OFF, the appliance will not start the ( 3 sec. ) start-up phase. - F + ENERGY SAVING STOP - OFF If the STOP function is set to OFF, the appliance will not start the shut down phase.
OPERATING INSTRUCTIONS Message “N” This indicates that NATURAL MODE has started. This function is only present on some appliances. For safety reasons, only power values P1 (default value) and P2 can be set. At the end, the appliance will go back to the power level set be- If the NATURAL MODE function is set, the appliance fore NATURAL MODE.
OPERATING INSTRUCTIONS ( 3 sec. ) If the appliance is turned off manually, the program- ming has no effect and the appliance will not turn on - F + INSTALLER again automatically. In this case if the product is to be restarted, this must be ■...
OPERATING INSTRUCTIONS 17.3 DISPLAY ( 3 sec. ) The DISPLAY function allows the user to - F + STOVE STATUS select what is to appear on the main screen of the display set the display to switch off when the keypad is not in use ...
OPERATING INSTRUCTIONS Message "OFF T" If the grate is not emptied of uncombusted pellets, the next time the appliance is started up, a significant amount of uncombusted gas/smoke can form inside Refer to the section " OPERATION WITH AN EXTERNAL the firebox which will compromise safety if there is no THERMOSTAT ".
OPERATING INSTRUCTIONS 19.2 SAFETY WARNINGS Warning “E1” The pressure switch or the door open sensor (if present) have trig- Below are the warnings which appear together with the acoustic gered. Electrical power to the auger is interrupted, thus stopping signals which may be activated in the case of malfunctions. pellet feed to the grate, followed by the appliance shut down phase beginning.
OPERATING INSTRUCTIONS Warning “E2” Warning “E4” On appliance start-up, a malfunction in the pressure switch has The temperature detected by the smoke probe has exceeded the been detected. The shut down phase begins. set safety limit. Electrical power to the auger is interrupted, thus stopping pellet feed to the grate, followed by the appliance shut POSSIBLE CAUSES ACTION...
OPERATING INSTRUCTIONS Warning “E7” Warning “E9” The temperature detected by the smoke probe is below the min- During start-up, the appliance does not reach the start-up tem- imum operating temperature. The appliance shut down phase perature threshold within the set time. begins.
OPERATING INSTRUCTIONS Warning “E12” Warning “E14” A malfunction has been detected in the smoke extractor fan. The appliance has not reached the start-up temperature thresh- The appliance shut down phase begins. old within the set time. POSSIBLE CAUSES ACTION POSSIBLE CAUSES ACTION Operations which require the intervention of the T.A.C.
OPERATING INSTRUCTIONS With CHRONO settings: The control panel does not switch on power failure around the start time POSSIBLE CAUSES ACTION - command non executed - the appliance does not re-start when power is restored. Interventions which may be carried out by the user power failure around the stop time Power supply failure from the Check the electrical system of...