Eurotech ReliaCOR 40-13 Hardware Manual

Fanless edge ipc for industrial applications up to 13th intel core i9
Table of Contents

Advertisement

Quick Links

ReliaCOR 40-13
Fanless Edge IPC for Industrial Applications
Up to 13th Intel Core i9
Hardware Manual
EN
Original instructions
Document code: RECOR-40-13-HWM-EN-1-0-CU2
Document revision: 1-0-CU2 (2024.08.28)
FOR SAFE AND PROPER USE,
FOLLOW THESE INSTRUCTIONS.
KEEP THEM FOR FUTURE REFERENCE.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ReliaCOR 40-13 and is the answer not in the manual?

Questions and answers

Summary of Contents for Eurotech ReliaCOR 40-13

  • Page 1 ReliaCOR 40-13 Fanless Edge IPC for Industrial Applications Up to 13th Intel Core i9 Hardware Manual Original instructions Document code: RECOR-40-13-HWM-EN-1-0-CU2 Document revision: 1-0-CU2 (2024.08.28) FOR SAFE AND PROPER USE, FOLLOW THESE INSTRUCTIONS. KEEP THEM FOR FUTURE REFERENCE.
  • Page 2: Intended Audience Of This Document

    ReliaCOR 40-13 Hardware Manual EN Intended audience of this document This document is intended for system integrators. System integrator is a term applied to skilled persons who are specialized in linking together, physically or functionally, different computing systems and software applications to operate as a coordinated whole in compliance with the applicable regulations.
  • Page 3: Getting Started

    "Mechanical specifications" on page 48 4. Start developing your IoT applications The ReliaCOR 40-13 supports the Eurotech Everyware Software Framework (ESF). ESF is a smart application container that enables remote management of IoT gateways and gives a wide range of APIs allowing you to write and deploy your own IoT application.
  • Page 4: Table Of Contents

    ReliaCOR 40-13 Hardware Manual EN Contents ONTENTS Intended audience of this document Manufacturer information Trademarks Revision history Getting started Contents 1 Safety instructions 1.1 Important information 1.2 Explanation of messages 1.3 Power supply safety instructions 1.3.1 What to do before you supply power to the product 1.4 Battery safety instructions...
  • Page 5 Contents ReliaCOR 40-13 Hardware Manual EN 5.5.1 Documents related to IEC 62443 5.5.2 Cybersecurity and product life-cycle 6 Interfaces overview 6.1 Front side interfaces overview 6.2 Service Panel and Service Interfaces overview 6.2.1 Anti-Tamper Function 6.2.2 Service Interfaces overview 6.2.3 How to remove the Front Panel and the Service Panel cover 6.2.4 How to reinstall the Service Panel cover and the Front Panel...
  • Page 6 ReliaCOR 40-13 Hardware Manual EN Contents Notes Document code: RECOR-40-13-HWM-EN-1-0-CU2 6 / 58 Document revision: 1-0-CU2 (2024.08.28)
  • Page 7: Safety Instructions

    ReliaCOR 40-13 Hardware Manual EN 1 Safety instructions AFETY INSTRUCTIONS This chapter gives the following information: 1.1 Important information 1.2 Explanation of messages 1.3 Power supply safety instructions 1.4 Battery safety instructions 1.5 Product handling safety instructions Document code: RECOR-40-13-HWM-EN-1-0-CU2 7 / 58 Document revision: 1-0-CU2 (2024.08.28)
  • Page 8: Important Information

    Failure to obey these instructions, violates the standards of safety, design, manufacture, and intended use of the product. Eurotech assume no liability for damages caused by failure to obey these instructions. If you have questions about these instructions, refer to: https://www.eurotech.com/support.
  • Page 9: Power Supply Safety Instructions

    Make sure that the product installation is made correctly and in compliance with the relevant standards and regulations Make sure that you supply power only after the product installation is completed. If you have questions about these instructions, refer to: https://www.eurotech.com/support. Document code: RECOR-40-13-HWM-EN-1-0-CU2 9 / 58...
  • Page 10: Battery Safety Instructions

    1 Safety instructions ReliaCOR 40-13 Hardware Manual EN Battery safety instructions WARNING If the battery is used incorrectly it can explode, leak, and can cause injury. To avoid these risks, refer to "How to safely use the battery" below. 1.4.0.1...
  • Page 11: Consignes De Sécurité

    ReliaCOR 40-13 Hardware Manual EN 2 Consignes de sécurité ONSIGNES DE SÉCURITÉ Ce chapitre fournit les informations suivantes: 2.1 Informations importantes 2.2 Explication des messages 2.3 Instructions de sécurité pour l'alimentation électrique 2.4 Instructions de sécurité pur la batterie 2.5 Instructions de sécurité pour la manipulation du produit...
  • Page 12: Informations Importantes

    Le non-respect de ces instructions constitue une violation des normes de sécurité, de conception, de fabrication et d'utilisation prévue du produit. Eurotech rejette toute responsabilité pour les dommages causés en cas de non-respect de ces instructions. En cas de doutes sur ces instructions, consultez le site: https://www.eurotech.com/support.
  • Page 13: Instructions De Sécurité Pour L'alimentation Électrique

    Assurez-vous que l'installation du produit soit effectuée correctement et en conformité avec les normes et réglementations en vigueur Assurez-vous de ne fournir l'alimentation qu'une fois l'installation du produit terminée. En cas de doutes sur ces instructions, veuillez consulter le site: https://www.eurotech.com/support. Document code: RECOR-40-13-HWM-EN-1-0-CU2 13 / 58...
  • Page 14: Instructions De Sécurité Pur La Batterie

    2 Consignes de sécurité ReliaCOR 40-13 Hardware Manual EN Instructions de sécurité pur la batterie AVERTISSEMENT Si la batterie est utilisée de manière incorrecte elle peut exploser, couler, ou causer des dommages. Pour éviter ce phénomène dangereux, voir "Comment utiliser la batterie en toute sécurité" ci- dessous.
  • Page 15: Technical Terms And Graphical Symbols

    ReliaCOR 40-13 Hardware Manual EN 3 Technical terms and graphical symbols ECHNICAL TERMS AND GRAPHICAL SYMBOLS This chapter gives the following information: 3.1 Technical terms (acronyms, abbreviations) 3.2 Graphical symbols Document code: RECOR-40-13-HWM-EN-1-0-CU2 15 / 58 Document revision: 1-0-CU2 (2024.08.28)
  • Page 16: Technical Terms (Acronyms, Abbreviations)

    3 Technical terms and graphical symbols ReliaCOR 40-13 Hardware Manual EN Technical terms (acronyms, abbreviations) The following technical terms (acronyms, abbreviations) can be used in this manual: Les termes techniques suivants (acronymes, abréviations) peuvent être utilisés dans ce manuel: Term...
  • Page 17: Product Overview

    ReliaCOR 40-13 Hardware Manual EN 4 Product overview RODUCT OVERVIEW This chapter gives the following information: 4.1 Product description 4.2 Intended use and not allowed uses of the product 4.3 Technical specifications Document code: RECOR-40-13-HWM-EN-1-0-CU2 17 / 58 Document revision: 1-0-CU2 (2024.08.28)
  • Page 18: Product Description

    ReliaCOR 40-13 Hardware Manual EN Product description The ReliaCOR 40-13 is a compact, fanless platform that supports a wide range of workloads at the Edge. Designed for industrial use cases, it offers reliable operation thanks to industrial grade ruggedization and a robust power supply.
  • Page 19 ReliaCOR 40-13 Hardware Manual EN 4 Product overview The product can be optionally configurated with Everyware GreenEdge (EGE), IoT edge software solution qualified for AWS IoT Greengrass V2. EGE reduces onboarding time with just a few clicks, provides factory-generated trusted identity, seamless southbound connectivity, easy cloud integration and device management while consolidating IoT costs into one AWS bill.
  • Page 20: Intended Use And Not Allowed Uses Of The Product

    4.2.2 Intended use The ReliaCOR 40-13 is a compact, fanless platform that supports a wide range of workloads at the Edge. Designed for industrial use cases, it offers reliable operation thanks to industrial grade ruggedization and a robust power supply.
  • Page 21: Technical Specifications

    The ReliaCOR 40-13 family includes several ordering codes (product variants): Ordering code (product variant) = RECOR-40-13-xx-yy -xx identifies the hardware variant -yy identifies the software variant The ReliaCOR 40-13 family has the following hardware and software technical specifications: 4.3.1 Hardware technical specifications Ordering Code: RECOR-40-13-xx-yy Hardware Variant -xx...
  • Page 22: Software Technical Specifications

    4 Product overview ReliaCOR 40-13 Hardware Manual EN Ordering Code: RECOR-40-13-xx-yy Hardware Variant -xx ENVIRONMENT Operating Temp -25 to +50°C without external air flow, +65°C with mild external air flow Storage Temp -30 to +85°C Humidity 10 to 95% Non-condensing CERTIFICATIONS...
  • Page 23: Certifications

    ReliaCOR 40-13 Hardware Manual EN 5 Certifications ERTIFICATIONS Note about the Declaration of Conformity Upon request, Eurotech can provide the product Declaration of Conformity. For more information, refer to: https://www.eurotech.com/support. This chapter gives the following information: 5.1 CE marking 5.2 REACH compliance 5.3 FCC compliance...
  • Page 24: Ce Marking

    Member States relating to electromagnetic compatibility. Modification statement Eurotech does not approve any changes or modifications to this product by the user. Any changes or modifications could void the user’s authority to operate this product. 24 / 58 Document code: RECOR-40-13-HWM-EN-1-0-CU2 Document revision: 1-0-CU2 (2024.08.28)
  • Page 25: Reach Compliance

    Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH), with the exceptions allowed by the EU Technical Committee. Eurotech has set in place a monitoring process to assess compliance to REACH regulation. For details and more information, refer to: https://www.eurotech.com/support. Document code: RECOR-40-13-HWM-EN-1-0-CU2 25 / 58 Document revision: 1-0-CU2 (2024.08.28)
  • Page 26: Fcc Compliance

    This product is FCC marked and complies with the regulatory information reported in the following sections. Eurotech is not responsible for the use of the product together with equipment (for example: power supplies, personal computers, etc.) that are not FCC marked and not compliant with the requirements specified in this instructions for use.
  • Page 27: Ised Canada Compliance

    ReliaCOR 40-13 Hardware Manual EN 5 Certifications ISED Canada compliance This section applies to all product variants. This device complies with ISED Canada. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 28: Iec 62443 (Cybersecurity)

    ReliaCOR 40-13 Hardware Manual EN IEC 62443 (cybersecurity) The following sections refer to the ReliaCOR 40-13 configurations that are IEC 63443 4-1 and 4-2 certified for cybersecurity. Any change/ modification of the product requires the reassessment of the cybersecurity certification.
  • Page 29: Interfaces Overview

    ReliaCOR 40-13 Hardware Manual EN 6 Interfaces overview NTERFACES OVERVIEW This chapter gives the following information: 6.1 Front side interfaces overview 6.2 Service Panel and Service Interfaces overview 6.3 Rear side interfaces overview Document code: RECOR-40-13-HWM-EN-1-0-CU2 29 / 58 Document revision: 1-0-CU2 (2024.08.28)
  • Page 30: Front Side Interfaces Overview

    6 Interfaces overview ReliaCOR 40-13 Hardware Manual EN Front side interfaces overview Note on the torque: set the torque force to 3.5 kgf·cm (0.34 N·m) to loosen/tighten the screws. The Front side interfaces are as follows: Fig. 2 - Front side interfaces layout Ref #...
  • Page 31: Service Panel And Service Interfaces Overview

    ReliaCOR 40-13 Hardware Manual EN 6 Interfaces overview Service Panel and Service Interfaces overview The Service Panel is placed on the front side and contains the Service Interfaces. To get access to the Service Panel, you have to remove the Front Panel.
  • Page 32: How To Remove The Front Panel And The Service Panel Cover

    6 Interfaces overview ReliaCOR 40-13 Hardware Manual EN 6.2.3 How to remove the Front Panel and the Service Panel cover NOTICE The IP rating is not maintained when the Front Panel / the Service Panel cover are removed. Do not use the product for long periods with the Front Panel / the Service Panel cover removed, otherwise dust and other particulates can go into the system.
  • Page 33: How To Reinstall The Service Panel Cover And The Front Panel

    ReliaCOR 40-13 Hardware Manual EN 6 Interfaces overview 6.2.4 How to reinstall the Service Panel cover and the Front Panel Required item: 1x TR8 Torx security screwdriver. Note on the torque: set the torque force to 3.5 kgf·cm (0.34 N·m) to loosen/tighten the screws.
  • Page 34: How To Replace The Cmos Battery

    6 Interfaces overview ReliaCOR 40-13 Hardware Manual EN 6.2.5 How to replace the CMOS battery WARNING Serious harm if battery is used incorrectly. Before using the battery: 1. Always obey to the instructions given in the section "Battery safety instructions" on page 10...
  • Page 35 ReliaCOR 40-13 Hardware Manual EN 6 Interfaces overview 6. Reinstall the battery holder (Fig. 10 below) 7. Tighten the 2 cross-head screws (M2.5, L = 3.5 mm). Fig. 10 - Reinstall the battery holder 8. Reinstall the Service Panel cover and the Front Panel (for more information, refer to "How to...
  • Page 36: Rear Side Interfaces Overview

    6 Interfaces overview ReliaCOR 40-13 Hardware Manual EN Rear side interfaces overview Note on the torque: set the torque force to 3.5 kgf·cm (0.34 N·m) to loosen/tighten the screws. The Rear side interfaces are as follows: Fig. 11 - Rear side interfaces layout Ref #...
  • Page 37: Interfaces In Detail

    ReliaCOR 40-13 Hardware Manual EN 7 Interfaces in detail NTERFACES IN DETAIL This chapter gives the following information: 7.1 Serial Ports connectors 7.2 CAN connectors 7.3 Digital I/Os connector 7.4 Remote Power Switch connector Document code: RECOR-40-13-HWM-EN-1-0-CU2 37 / 58...
  • Page 38: Serial Ports Connectors

    7 Interfaces in detail ReliaCOR 40-13 Hardware Manual EN Serial Ports connectors The ReliaCOR 40-13, on the rear side, has 2x Serial Ports connectors. 7.1.1 Serial Ports connectors specifications Connector Layout: Connector Pinout in RS-232 Mode: Pin # Signal Type Description...
  • Page 39: Can Connectors

    Mating Connector Specifications: Standard 9-Pin D-Sub (socket) Gender: Female Digital I/Os connector The ReliaCOR 40-13, on the rear side, has a connector with the following I/O interfaces: 8x Digital OUT (isolated) 8x Digital IN (isolated) 7.3.1 Digital I/Os connector specifications...
  • Page 40: Remote Power Switch Connector

    7 Interfaces in detail ReliaCOR 40-13 Hardware Manual EN Remote Power Switch connector The ReliaCOR 40-13, on the rear side, has a connector to install the Remote Power Switch. 7.4.1 Remote Power Switch connector specifications Connector Layout: Connector Pinout: Pin #...
  • Page 41: Product Power Supply Requirements

    ReliaCOR 40-13 Hardware Manual EN 8 Product power supply requirements RODUCT POWER SUPPLY REQUIREMENTS This chapter gives the following information: 8.1 Power specifications 8.2 Power IN connector specifications 8.3 Guidelines about the power supply cables to use Document code: RECOR-40-13-HWM-EN-1-0-CU2 41 / 58 Document revision: 1-0-CU2 (2024.08.28)
  • Page 42: Power Specifications

    8 Product power supply requirements ReliaCOR 40-13 Hardware Manual EN Power specifications The power input is protected against: surge, noise, reverse polarity, over-voltage. Specification Description Power Supply All product variants: 9 to 48 V DC (24 V DC Nominal); Ignition Key Function (not enabled...
  • Page 43: Product Installation

    ReliaCOR 40-13 Hardware Manual EN 9 Product installation RODUCT INSTALLATION This chapter gives the following information: 9.1 Transporting the product 9.2 Unpacking the product 9.3 Installing the product 9.4 Connecting the peripheral devices 9.5 Supplying power, turning ON/OFF the product Document code: RECOR-40-13-HWM-EN-1-0-CU2 43 / 58 Document revision: 1-0-CU2 (2024.08.28)
  • Page 44: Transporting The Product

    9 Product installation ReliaCOR 40-13 Hardware Manual EN Transporting the product When transporting the product, obey the following instructions. 9.1.1 Avoid heavy shocks and vibrations The built-in components of the product are sensitive to heavy shocks and vibrations. To avoid damages, during transportation use the original packaging and protect the product from heavy shocks and vibrations.
  • Page 45: Installing The Product

    ReliaCOR 40-13 Hardware Manual EN 9 Product installation Installing the product The product is intended for professional use and must be installed by qualified personnel only. The product must be installed in a secured location, accessible to authorized personnel only (for example in a cabinet / technical compartment).
  • Page 46: Connecting The Peripheral Devices

    Make sure that the product installation is made correctly and in compliance with the relevant standards and regulations Make sure that you supply power only after the product installation is completed. If you have questions about these instructions, refer to: https://www.eurotech.com/support. 46 / 58 Document code: RECOR-40-13-HWM-EN-1-0-CU2...
  • Page 47: Supplying Power And Turning On The Product

    9.5.2.1 Ignition Key Function In the ReliaCOR 40-13, the Ignition Key Function is not enabled by default. To enable it, get access to the Service Interfaces and set the "PC/CAR Mode Select Switch" on the position: Power Ignition Mode. For more information, refer to the "PC/CAR Mode Select Switch" in the section "Service Interfaces...
  • Page 48: Mechanical Specifications

    ReliaCOR 40-13 Hardware Manual EN 10 Mechanical specifications ECHANICAL SPECIFICATIONS This chapter gives the following information: 10.1 Product enclosure specifications and mechanical dimensions Document code: RECOR-40-13-HWM-EN-1-0-CU2 48 / 58 Document revision: 1-0-CU2 (2024.08.28)
  • Page 49: Product Enclosure Specifications And Mechanical Dimensions

    The product enclosure has the following specifications: Material: Metal The product has the following mechanical dimensions: 240 x 79 x 261 mm (W x H x D) - Excluding connectors and mounting brackets. Fig. 13 - ReliaCOR 40-13 mechanical dimensions (in mm) 49 / 58 Document code: RECOR-40-13-HWM-EN-1-0-CU2...
  • Page 50: Product Maintenance

    ReliaCOR 40-13 Hardware Manual EN 11 Product maintenance RODUCT MAINTENANCE This chapter gives the following information: 11.1 How to maintain the product Document code: RECOR-40-13-HWM-EN-1-0-CU2 50 / 58 Document revision: 1-0-CU2 (2024.08.28)
  • Page 51: How To Maintain The Product

    11 Product maintenance ReliaCOR 40-13 Hardware Manual EN 11.1 How to maintain the product WARNING The power cable remains energized even when disconnected from the product. Risk of electric shock and personal injury. Always make sure that all the power supply sources are disconnected and all the circuits are fully discharged before servicing.
  • Page 52: Eurotech Everyware Iot

    ReliaCOR 40-13 Hardware Manual EN 12 Eurotech Everyware IoT UROTECH VERYWARE This chapter gives the following information: 12.1 Everyware IoT 12.2 Everyware Cloud (EC) 12.3 Everyware Software Framework (ESF) Document code: RECOR-40-13-HWM-EN-1-0-CU2 52 / 58 Document revision: 1-0-CU2 (2024.08.28)
  • Page 53: Everyware Iot

    12.1 Everyware IoT Eurotech provides hardware and software IoT solutions under the brand name of Everyware IoT. Everyware IoT is an integrated platform for the Internet of Things which provides IoT gateways for any industry vertical, an open edge framework, and a modular cloud infrastructure to connect field devices to business analytics and enterprise applications.
  • Page 54: Esf Reference Port

    ReliaCOR 40-13 Hardware Manual EN 12 Eurotech Everyware IoT 12.3.1 ESF reference port According to the hardware variants, the reference ESF port to use is placed as follows: in the hardware variant -11, it is on the rear side, the first 2.5GbE RJ-45 port on the left (indicated...
  • Page 55: Product Decommissioning

    ReliaCOR 40-13 Hardware Manual EN 13 Product decommissioning RODUCT DECOMMISSIONING This chapter gives the following information: 13.1 What is the decommissioning process 13.2 How to do the decommissioning Document code: RECOR-40-13-HWM-EN-1-0-CU2 55 / 58 Document revision: 1-0-CU2 (2024.08.28)
  • Page 56: What Is The Decommissioning Process

    13.1 What is the decommissioning process The ReliaCOR 40-13 incorporates a tool to decommission the system. The decommissioning of the system is the same as restoring the factory restore image, but also deleting the backups saved in the recovery partition.
  • Page 57 ReliaCOR 40-13 Hardware Manual EN Notes OTES Document code: RECOR-40-13-HWM-EN-1-0-CU2 57 / 58 Document revision: 1-0-CU2 (2024.08.28)
  • Page 58: Download Area

    EUROTECH HEADQUARTERS Via Fratelli Solari, 3/a Email: welcome@eurotech.com Tel:  +39 0433.485.411 33020 Amaro (UD) - Italy Web: https://www.eurotech.com Fax: +39 0433.485.499 Contact us https://www.eurotech.com/contact-us Support Portal https://support.eurotech.com Download Area https://www.eurotech.com/download https://www.eurotech.com/support/rma All trademarks, registered trademarks, logos, trade names, products names contained in this document are the property of their respective owners.