The standard configuration of the auto lift off package includes the following: • Two platforms with basements stacking • Control unit • The package including the electric circuit, hydraulic connection, rubber blocks, oil-protection cover. Winntec Europe www.winntec.net Rechtzaad 6, 4703 RC Roosendaal, The Netherlands, +31 165 394 018, info@winntec.net...
Warn: The lift is suitable for lifting the vehicle and keeping the height in the garage. Forbid the other use like cleaning, scaffolding. Winntec Europe www.winntec.net Rechtzaad 6, 4703 RC Roosendaal, The Netherlands, +31 165 394 018, info@winntec.net...
The safety solenoid valve: All the solenoid valve adopts the closed design, the separate control hydraulic system can support the load. The valves are inside the control unit. Winntec Europe www.winntec.net Rechtzaad 6, 4703 RC Roosendaal, The Netherlands, +31 165 394 018, info@winntec.net...
• Connect the lines the lift. ⚠ The switch board is 415V/3PH, connect the transformer and the main electric machine jumping line when need 230 V. Winntec Europe www.winntec.net Rechtzaad 6, 4703 RC Roosendaal, The Netherlands, +31 165 394 018, info@winntec.net...
8. Repeat the operation of fill and exhaust of the cylinder above 2 times. ⚠ Continue the operation until the oil fulfill the hydraulic system and all the air exhausted. Repeat the operation step 6 once each month. Winntec Europe www.winntec.net Rechtzaad 6, 4703 RC Roosendaal, The Netherlands, +31 165 394 018, info@winntec.net...
• Press the “down” button if need to down to the ground. The lift stops automatically when declining 45cm above the ground. • Loosen the button and press the button again until the lift down to the lowest position. Winntec Europe www.winntec.net Rechtzaad 6, 4703 RC Roosendaal, The Netherlands, +31 165 394 018, info@winntec.net...
The lift can’t decline • The decline solenoid valve can’t open, • Check the decline valve and voltage • The circuit fault. • Check the circuit. Winntec Europe www.winntec.net Rechtzaad 6, 4703 RC Roosendaal, The Netherlands, +31 165 394 018, info@winntec.net...
⚠ You can’t get the 12 warrant if not follow the above regular. The final test and regularly check the lift. Winntec Europe www.winntec.net Rechtzaad 6, 4703 RC Roosendaal, The Netherlands, +31 165 394 018, info@winntec.net...