Download Print this page

ZETRON Telex IP-224 Technical Notes

Ethernet adapter

Advertisement

Quick Links

TECHNICAL NOTES
MT-4/5 Radio Systems
TN857 CI-IP-ADAPTER-1 Telex IP-224 Ethernet Adapter
The Telex IP-224 Ethernet Adapter provides a reliable means of remotely controlling up to two Zetron base stations
remotely. The adapter can be used in conjunction with Telex model C-6200, C-Soft, IP-1616 and IP-2002 consoles.
The IP-224 is interconnected to the distant remote control console(s) by means of any available Wide Area Network
(WAN) or Local Area Network (LAN) connection.
The IP-224 can be confi gured to operate in modes that allow it to connect to both digital and analog radios, and
perform a variety of other tasks related to using radios on a digital network. The IP-224 can be rack mounted
providing easy installation and service. A sleek LCD display provides user feedback when programming and VU
meters are provided on the front of the display for alignment purposes. All other confi gurations are completed in the
web browser confi guration windows.
The Telex IP-224 Ethernet Adapter provides the following features:
Ethernet TX and LINK LEDs
PTT (Push To Talk) Monitor, F1 and F2 relays
Four (4) PTT Modes and Three (3) Monitor Modes
Nine (9) Selectable PTT Frequencies
Seven (7) Digital Outputs for Channel Selection
CTCSS (Continuous Tone Coded Squelch System) Generation(64 frequencies)
Software Gain Control
Direct Radio Control
Handset Port for Monitoring Activity and Transmission
Single Function Tone Recognition (16 Function Tones)
AGC (Automatic Gain Control)
RX (Receive) Audio Squelch
ANI (Automatic Number Identifi cation) Over-the-Air Protocol
Up to 1000 function tones supported
MDC1 and FleetSync1 Encode/Decode
SOIP (Serial Over Internet Protocol)
Dual Ethernet Interface for Backup Solution
Supports RS485, CAN Bus, RS232 and TTL
Backwards Compatible with Telex Radio Dispatch Products
Secure Remote Web Browser Programming and Confi guration
Single or Dual Function Tone Generation
Guard Tone User-Selectable for 2100Hz, 2175Hz, 2300Hz, 2325Hz,2400Hz, 2600Hz, 2800Hz, 2850Hz or 2900 Hz
Menu Driven Front Panel Control for TX, RX, Spare Audio, and CTCSS
TECHNICAL NOTE:
ZETRON.COM
TN857, REV 3-0-0, © Jul 2024
LMRSALES@ZETRON.COM
CANADA/US
| TOLL FREE
+1 250 382 8268
+1 800 664 4066
Page 1 of 10

Advertisement

loading
Need help?

Need help?

Do you have a question about the Telex IP-224 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ZETRON Telex IP-224

  • Page 1 TN857 CI-IP-ADAPTER-1 Telex IP-224 Ethernet Adapter The Telex IP-224 Ethernet Adapter provides a reliable means of remotely controlling up to two Zetron base stations remotely. The adapter can be used in conjunction with Telex model C-6200, C-Soft, IP-1616 and IP-2002 consoles.
  • Page 2 TN857 CI-IP-ADAPTER-1 Telex IP-224 Ethernet Adapter Wiring Diagram for MT-4 SR-39-1 Subrack: On the MT-4 subrack, the optional A-PNL-AUX96-3 auxiliary connector can be used to connect the Telex IP-224 to a Zetron Base Station, as shown in Figure 1. ZETRON MT-4 SUBRACK...
  • Page 3 TN857 CI-IP-ADAPTER-1 Telex IP-224 Ethernet Adapter Wiring Diagram for MT-5 MT5-SR-00-01 Subrack: On the MT-5 subrack, the Auxiliary Board Terminal Blocks can be used to connect the Telex IP-224 to a Zetron Base Station, as shown in Figure 2. ZETRON MT-5 SUBRACK...
  • Page 4 While the wiring can be connected to the auxiliary terminals on the rear of the MT-4 and MT-5 subracks, both subracks also include a female DB25 connector on the back of the subrack, which can also be used for connecting to a Telex IP-224, using a straight-through male DB25 to male DC37 cable as follows: CBLC40-DB0DC061...
  • Page 5 Power Connection to IP-224 Power and Ground for the Telex IP-224 must be connected to the main power connector (J8) on the MT-4 subrack, or the Auxiliary Terminal Board (J4) on the MT-5 subrack. The DB25 does not supply power to the IP-224.
  • Page 6 Figure 6: IP-224 Front and Back Panel Initial Setup Step 1 - Program the Telex IP-224 for your system. Zetron makes the following changes from default: - Ethernet Setup: IP Address, Subnet Mask and Default Gateway - Multicast Setup: Set RX Mcast, TX Mcast and Mcast address at 224.0.0.13 - Per Line Setup: CTCSS Setup Always On, Digital Outputs set from 0 up, COR Enable, Hi-Pass RX, and PTT Notch Filter selected, Monitor Relay set to Timed 1000 ms.
  • Page 7 AC-3E Audio Control Card or CI-BC-4E Base Control Card The AC-3E Audio Control Card or CI-BC-4E Base Control Card can be added to a system, which connects that control card between the Tx/Rx modules and the Telex IP-224. This would allow more confi gurability to the radio system.
  • Page 8 TECHNICAL NOTES MT-4/5 Radio Systems TN857 CI-IP-ADAPTER-1 Telex IP-224 Ethernet Adapter Schematic for DB25 Connector (J10) on MT-4 SR-39-1 Subrack Figure 7: MT-4 Subrack DB25 Connector Schematic Diagram TECHNICAL NOTE: ZETRON.COM TN857, REV 3-0-0, © Jul 2024 LMRSALES@ZETRON.COM CANADA/US | TOLL FREE...
  • Page 9 TECHNICAL NOTES MT-4/5 Radio Systems TN857 CI-IP-ADAPTER-1 Telex IP-224 Ethernet Adapter Schematic for DB25 Connectors (J7 & J8) on MT-5 MT5-SR-00-01 Subrack Figure 8: MT-5 Subrack DB25 Connectors Schematic Diagram TECHNICAL NOTE: ZETRON.COM TN857, REV 3-0-0, © Jul 2024 LMRSALES@ZETRON.COM...
  • Page 10 TECHNICAL NOTES MT-4/5 Radio Systems TN857 CI-IP-ADAPTER-1 Telex IP-224 Ethernet Adapter This Page Intentionally Left Blank TECHNICAL NOTE: ZETRON.COM TN857, REV 3-0-0, © Jul 2024 LMRSALES@ZETRON.COM CANADA/US | TOLL FREE +1 250 382 8268 +1 800 664 4066 Page 10 of 10...

This manual is also suitable for:

Tn857