Table of Contents

Advertisement

Quick Links

GC68C-B8056
Service Engineer's Manual
1
http://www.tyan.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GC68C-B8056 and is the answer not in the manual?

Questions and answers

Summary of Contents for TYANO GC68C-B8056

  • Page 1 GC68C-B8056 Service Engineer’s Manual http://www.tyan.com...
  • Page 2: Trademark Recognition

    PREFACE Copyright This publication, including all photographs, illustrations, and software, is protected under international copyright laws, with all rights reserved. Neither this manual, nor any material contained herein, may be reproduced without written consent of manufacturer. Copyright 2024 MITAC COMPUTING TECHNOLOGY CORPORATION. All ®...
  • Page 3 FCC Declaration ● Notice for the USA Compliance Information Statement (Supplier's Declaration of Conformity, SDoC) FCC Part 15: This device complies with part 15 of the FCC Rules. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: ‧This device may not cause harmful interference.
  • Page 4 Warning This equipment is compliant with Class A of CISPR 32. In a residential environment this equipment may cause radio interference. CAUTION Lithium battery included with this board. Do not puncture, mutilate, or dispose of battery in fire. There will be danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by manufacturer.
  • Page 5 How this guide is organized This guide contains the following parts: Chapter 1: Overview This chapter provides an introduction to the TYAN GC68C-B8056 barebones and standard parts list, describes the external components, gives an overview of the product from different angles.
  • Page 6: Safety And Compliance Information

    Safety and Compliance Information Before installing and using TYAN GC68C-B8056, take note of the following precautions: ·Read all instructions carefully. ·Do not place the unit on an unstable surface, cart, or stand. ·Do not block the slots and opening on the unit, which are provided for ventilation.
  • Page 7: Safety Information

    Safety Information Retain and follow all product safety and operating instructions provided with your equipment. In the event of a conflict between the instructions in this guide and the instructions in equipment documentation, follow the guidelines in the equipment documentation. Observe all warnings on the product and in the operating instructions.
  • Page 8: General Precautions

    General Precautions · Follow all caution and warning instructions marked on the equipment and explained in the accompanying equipment documentation. Machine Room Environment · This device is for use only in a restricted access location, such as a machine room or IT room. ·...
  • Page 9 from the horizontal. · Make sure the rack is properly secured to the floor or ceiling. · Make sure the stabilizing feet are attached to the rack if it is a single-rack installation. · Make sure racks are coupled together if it is a multiple-rack installation. ·...
  • Page 10: Equipment Modifications

    Equipment Power Cords · Use only the power cords and power supply units provided with your system. The system might have one or more power cords. · Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at all times.
  • Page 11 Equipment Repairs and Servicing · The installation of internal options and routine maintenance and service of this product should be performed by skilled person who are knowledgeable about the procedures, precautions, and hazards associated with equipment containing hazardous energy levels. ·...
  • Page 12 安全資訊 請保留和遵守隨本設備提供的所有產品安全與操作說明。本指南的說明與設 備文件的說明內容如有沖突,請遵守設備文件中的指導。 遵守產品上和操作說明中的所有警告。為降低人身傷害、電擊、火災及設備 損壞的風險,請遵守本指南中包括的所有注意事項。 在安裝、操作和維修產品之前,您必須先熟悉本指南中的安全資訊。 設備上的符號 請注意。 該符號表示可能存在危險。如果未遵守注意事項,則 可能出現傷害。請查閱設備文件了解詳細資訊。 請注意。 請勿在抽取式儀器上放置物品或將儀器頂部當作工作 檯。 警告。 該符號表示存在高壓電路或電擊危險。所有維修工作 應交由專業人員。 警告。 該符號表示表面或元件高溫。如果接觸到表面,則可 能被燙傷。為降低被高溫元件燙傷的風險,請在接觸 之前,先讓表面冷卻下來。 維修前須切斷所有電源 一般注意事項 遵守設備上標示的以及隨附設備文件中介紹的所有注意事項和警告資訊。  http://www.tyan.com...
  • Page 13 機房環境 本裝置僅適用於機房或資訊室。  確保系統安裝的區域通風良好,溫度濕度等可控制。  確保機房電源的電壓和頻率與設備電力標籤上標示的電壓和頻率相符。  安裝系統時應遠離高壓、排氣管、散熱器等。  切勿在潮濕環境中使用本產品。  設備底座 請勿堵塞或蓋住系統的槽孔。  切勿將任何物件插入設備的槽孔。內部可能存在高壓。  可導電的物件可能造成短路並引起火災、電擊或設備損壞。  雙膝彎曲,用雙手提起設備。  設備機架 避免人身傷害或設備損壞指引: 遵守當地的職業健康和安全規定以及手工物料搬運的指導。  請勿嘗試獨自搬動機架,搬動機架至少需要兩人。  請勿嘗試搬動滿載的機架。從機架上卸下設備後再搬動它。  請勿嘗試在大於 10 度的斜坡上搬動機架,以免造成危險。  確保機架已正確固定到地板或天花板上。  如果是單機架安裝,確保穩定支腳已裝到機架。  如果是多機架安裝,確保各機架已咬合在一起。  將裝置安裝到機架之前,確保機架是水平和穩定的。  確保承重腳已伸展至地板。...
  • Page 14 確保一次只有一個元件被伸展。如果一次伸展一個以上的元件,則機架可  能會不穩定。 避免設備損壞指引: 機架寬度和深度必須保證能夠適當地進行維修和排列纜線。  保證機架內的通風良好。安裝不當或通風不良可能會損壞設備。  機架不能有實心或受限制的通風門。您必須在機架前後使用絲網門,或者  將門卸下以保證系統的良好通風。 如果您在機架中安裝設備,請勿將設備放在裝置上。這會造成通風不暢,  並可能會造成設備損壞。 確保產品與護欄正確咬合。與護欄咬合不良的產品可能會不穩定。  驗證為機架提供電源的交流電源分支電路沒有多載, 以降低人身傷害、  電擊、火災及設備損壞的風險。 機架總負載不應超過分支電路額定值的 80%。請向對您的設備連線和安  裝規定具有管轄權限的電力部門查詢。 設備電源線 只使用隨系統提供的電源線和電源裝置。系統可能配有一條或多條電源  線。 將電源線插入到能方便接觸到的接地電源插座。  在歐洲供電環境中,您必須將電源線上的綠色/ 黃色接頭接地。如果沒有  將綠色/黃色接頭接地,則可能由於大量電流洩露而造成電擊。 請勿在交流電源線或纜線上放置物件。將電源線或纜線放在人們不易踩到  或被絆倒的地方。 請勿拉扯電源線或纜線。從電源插座上斷開電源線時,應抓住電源線插  頭。 為降低電擊風險,請在維修裝置之前,斷開所有電源線連接。...
  • Page 15 設備電池 本系統使用鋰錳電池。如果電池組處理不當,則會有起火風險。  請勿拆解、擠壓、穿刺電池,將其投入火中或水中,或使其與外部短路接  觸。 請勿將電池置於 60 F) 以上的高溫環境中。 C (140 ° °  系統電池不可變更。如果更換不正確的電池,則會有爆炸危險。請換上專  為本產品指定的備用電池。 請勿嘗試給電池充電。  按照製造商的說明處理用過的電池。請勿將電池當作一般家庭垃圾處理。  若要對電池進行回收再用或正確處理,請使用公共收集系統,或將其送回授 權合作夥伴或其代理。 設備改造 不要對本設備進行機械或電氣修改, 以免造成安全問題。對於被改造設備  的認證合格概不負責。 設備維修與維護 安裝內部元件和日常的產品維護應由熟悉程序、注意事項及高壓設備危險  的專業人員執行。 請勿任意拆裝設備. 任何未經授權或認證人員之設備拆裝可能造成嚴重的  安全問題. 任何問題, 請洽您的銷售人員或經銷商尋求協助。 除非安裝手冊或使用手冊中提及, 否則請勿嘗試維修您的設備. 永遠遵守 ...
  • Page 16 卸下或更換系統元件時,請戴上手套,以免被高溫的元件表面燙傷。  如果產品持續發生損壞,需要維修,請從交流電源插座上斷開產品,並交  由授權的服務提供商進行維修。下面是一些需要維修的情況: – 電源線、延長線或插頭損壞。 – 有液體濺到產品上,或異物進入到產品內。 – 產品遭到雨淋或進水。 – 產品跌落或損壞。 – 在您按照操作說明使用時,產品操作不正常。 操作環境溫度升高 如果將此設備安裝在封閉式或具有多個設備的機架上,機架的操作環境溫  度可能會高於設備房間的溫度。因此,在安裝此設備時必須考慮滿足生產廠 商規定的最高環境溫度 (Tma) 要求。 減少通風 將設備安裝於機架上不會造成安全操作設備所需的通風出現通風不良的狀  況。 機械負載 將設備安裝於機架上不會造成因為機械負載不均而出現危險的狀況。  電路過度負荷 必須考量將設備連接到供電電路時的狀況,而過流防護及供電線路可能出  現電路過度負荷的問題。對於這類疑慮,必須妥適考量設備標示牌的額定 值。 http://www.tyan.com...
  • Page 17 牢固的地面固定 務必使安裝於機架上的裝置在地面固定牢固。必須特別注意非直接接上電  源的其他分路供電 (例如使用電源排插座)。 可更換電池 警告使用者: 警告: 為避免電磁干擾,本產品不應安裝或使用於住宅環境。 連絡方式 製造商: 神雲科技股份有限公司 地址: 桃園市龜山區文化二路 200 號 電話: 886‐3‐3275988 http://www.tyan.com...
  • Page 18 Taiwan BSMI RoHS Declaration 設備名稱:伺服器 / 型號(型式):GC68C-B8056 Equipment Name:Server / Type:GC68C-B8056 限用物質及其化學符號 Restricted substances and its chemical symbols 六價鉻 多溴聯苯 多溴二苯醚 單位 鉛 汞 鎘 Unit Hexavalent Polybrominated Polybrominated Lead Mercury Cadmium Chromium biphenyls diphenyl ethers (Pb) (Hg) (Cd) (PBB) (PBDE) 印刷電路板總成...
  • Page 19: Table Of Contents

    Table of Contents Chapter 1: Overview............... 21   About the TYAN GC68C-B8056 ..........21   Product Models ............... 21   Features .................. 22   Standard Parts List ..............27   1.4.1 Box Contents and Accessories ........27   About the Product ..............28  ...
  • Page 20 Replacing the USB Board ............65   3.6.1 USB Board Features ............66   Replacing the HDD Backplane Board ........67   3.7.1 HDD BP Board Features ..........68   Replacing Power Distribution Board ........69   3.8.1 Power Distribution Board Features ......... 70  ...
  • Page 21: Chapter 1: Overview

    2.5” NVMe devices including (4) 2.5” hot-swappable SATA 6G/SAS 12G. The GC68C-B8056 uses TYAN’s latest chassis featuring a robust structure and a solid mechanical enclosure. All of this provides GC68C-B8056 the power and flexibility to meet the needs of nowadays server applications.
  • Page 22: Features

    Features B8056G68CE12HR-2T Specifications Form Factor 1U Rackmount Chassis Model GC68C System Dimension (D x W x H) 26.77" x 17.26" x 1.69" (680 x 438.5 x 43mm) Motherboard Name S8056GM2NRE-2T Board Dimension Prop. 14.18" x 12.16" (360.2 x 308.8mm) Buttons (1) PWR w/ LED / (1) ID w/ LED Front Panel LEDs...
  • Page 23 Controller Intel X710-AT2 Realtek RTL8211F Connector (1) SFF-TA-1016 (MCIO 8x) for (4) SATA ports Storage SATA Controller Direct from AMD EPYC CPU Connector (M.2) (2) 22110/2280 (by PCIe Gen.4 interface) Storage NVMe Connector (U.2) (6) SFF-TA-1016 (MCIO 8x) for (12) front NVMe Connector type D-Sub 15-pin Graphic...
  • Page 24 Operating Non-operating Temp. - 40° C ~ 70° C (-40° F ~ 158° F) Environment In/Non-operating 90%, non-condensing at 35° C Humidity 90 Barebone (1) GC68C-B8056 Barebone Package Contains Manual (1) Quick Installation Guide RoHS RoHS 6/6 Compliant B8056G68CE12HR Specifications...
  • Page 25 4800/3600 memory Memory channel 12 Channels per CPU Memory voltage 1.1V PCIe (2) PCI-E Gen.5 x16 slot Pre-installed TYAN Riser (1) M7136G68-L16-1F riser card for (1) FH/HL Card (PCIe Gen.5) PCIe Gen.5 x16 slot (Left) / (1) Expansion Slots M7136G68-R16-1F riser card for (1) FH/HL PCIe Gen.5 x16 slot (Right) Others (1) PCI-E Gen.5 x16 OCP 3.0 mezzanine slot...
  • Page 26 Operating Non-operating Temp. - 40° C ~ 70° C (-40° F ~ 158° F) Environment In/Non-operating 90%, non-condensing at 35° C Humidity 90 Barebone (1) GC68C-B8056 Barebone Package Contains Manual (1) Quick Installation Guide RoHS RoHS 6/6 Compliant NOTE: 1. The specifications are subject to change without prior notice.
  • Page 27: Standard Parts List

    Standard Parts List This section describes GC68C-B8056 package contents and accessories. Open the box carefully and ensure that all components are present and undamaged. The product should arrive packaged as illustrated below. 1.4.1 Box Contents and Accessories If any items are missing or appear damaged, contact your retailer or browse to TYAN’s website for service:...
  • Page 28: About The Product

    About the Product The following views show you the product. 1.5.1 System Front View GC68C-B8056 (B8056G68CE12HR/B8056G68CE12HR-2T) Description Description USB 3.2 Gen.1 Port Power Button with green & red (M1725G68-USB pre-installed) Drive Trays ID Button with blue LED http://www.tyan.com...
  • Page 29 Front Panel Button and LED (M1724G68-FPB pre-installed) Item Color Behavior System Power On / Green Solid On Power Button Green/Red System Power Off / All Off System Warning / Red Solid On ID Button Blue ID Located / Blue Solid On HDD LED Definitions Drive Status Activity LED (Green)
  • Page 30: System Rear View

    1.5.2 System Rear View Description Description RJ45 LAN Port1 (10Gbs, for PSU0 B8056G68CE12HR-2T sku) PSU1 ID LED LAN3 (dedicated for IPMI)+ ID Button USB3.2 Gen1 Ports VGA Port OCP Card Area Expansion Slots (Full-height / Serial Port (COM1) Half-length PCI-E Gen.5 x16 card w/ tall bracket x2) Expansion Slots (Full-height / RJ45 LAN Port2 (10Gbs, for...
  • Page 31: Psu And Lan Led Indications

    1.5.3 PSU and LAN LED Indications PSU LED Indication Power supply status Power supply LED color No AC power to allPSU No AC power to single PSU only Only +5V standby output on (AC OK) Amber Power supply DC output ON and OK Green Power supply fail Amber...
  • Page 32: System Top View

    1.5.4 System Top View Description Description M1725G68-USB (pre-installed) PSU0 PSU1 M1724G68-FPB (pre-installed) 2.5” SSD/HDD Trays* M1299G68A-BPE-12 (3) 4028 + (3) 4056 fans (pre-installed) Riser Card Bracket M1631G68-D-85A-PDB (M7136-R16-1F & (pre-installed) M7136-L16-1F pre-installed) http://www.tyan.com...
  • Page 33: Chassis Dimensions

    1.5.5 Chassis Dimensions http://www.tyan.com...
  • Page 34: Chapter 2: Setting Up

    Chapter 2: Setting Up 2.0.1 Before you Begin This chapter explains how to install the CPUs, CPU heatsinks, memory modules, and hard drives. Instructions on inserting add on cards are also given. 2.0.2 Work Area Make sure you have a stable, clean working environment. Dust and dirt can get into components and cause malfunctions.
  • Page 35: Precautions

    Working on a system that is connected to a power supply can be extremely dangerous. Follow the guidelines below to avoid damage to GC68C-B8056 or injury to yourself.  Ground yourself properly before removing the top cover of the system.
  • Page 36: Installing Motherboard Components

    This section describes how to install components on to the motherboard, including CPUs, memory modules and add-on cards. 2.1.1 Removing the Chassis Cover Follow these instructions to remove the GC68C-B8056 chassis cover. 1. Use a screw driver to loosen the screw. 2. Slide to lift up the rear top cover. http://www.tyan.com...
  • Page 37 3. Slide out the drive trays. Unscrew the front top cover and then slide it forwards to lift it up. http://www.tyan.com...
  • Page 38: Replacing The Chassis Cover

    2.1.2 Replacing the Chassis Cover Follow these instructions to replace the GC68C-B8056 chassis cover. Place the front top cover on the chassis and slide it backwards. Secure the front top cover with two screws and then insert the HDD drives into the chassis.
  • Page 39: Installing The Cpu And Heat Sink

    2.1.3 Installing the CPU and Heat sink Follow the steps below on installing CPU and CPU heat sink. The GC68C-B8056 supports single AMD Zen 4 (Genoa) series CPU. The following installation is based on an AMD SP5 socket. Use a T20 Torx screwdriver to loosen the screws securing the force frame.
  • Page 40 Align and install the carrier frame with package into the slot on the rail frame. Note: During installation, observe the following: NOTE: During installation, observe the following: 1. Make sure to push the carrier frame with package towards the end of the rail frame until it clicks into place. 2.
  • Page 41 To secure the heatsink, use a T20 Security Torx to tighten the screws. Tighten the six screws in a sequential order (123456) to secure the heat sink. Disassemble the heatsink in a sequential order (654321) to loosen the heatsink. Fully tightened or loosened one at a time. TORQUE: 12.5~15.0 KGF-CM (10.8~13.0 LBF-IN) NOTE: A new heatsink comes with pre-installed thermal...
  • Page 42: Installing The Memory Air Duct

    2.1.4 Installing the Memory Air duct Follow the steps below to install Memory Air duct. Align the air duct hook to the chassis. Press down the air duct onto the heatsink. The air duct installation has finished. http://www.tyan.com...
  • Page 43: Installing The Memory

    2.1.5 Installing the Memory Follow these instructions to install the memory modules onto the motherboard. Unlock the clips. Insert the memory module. Lock the clips. http://www.tyan.com...
  • Page 44: Installing The Expansion Card

    2.1.6 Installing the Expansion Card Follow these instructions to install the expansion card. Loosen two screws to take out the riser card bracket. Unscrew to remove the dummy bracket. Insert the expansion card into the riser card bracket and secure with a screw. http://www.tyan.com...
  • Page 45 Replace the Riser Card Bracket into the chassis. http://www.tyan.com...
  • Page 46: Installing The 2.5" Hard Drive

    2.1.7 Installing the 2.5” Hard Drive Follow these instructions to install the 2.5” hard drives to GT68C-B8056 system. 1. Press the locking tab to pull the lever open. 2. Slide the drive tray out. http://www.tyan.com...
  • Page 47 3. Press the locking tab to pull the tray side rail open. 4. Align the hard drive with the guide pins and install the hard drive into the drive tray. Close the tray side rail. http://www.tyan.com...
  • Page 48 5. Insert the drive tray into the chassis and close the lever. http://www.tyan.com...
  • Page 49: Installing The M.2 Latch

    2.1.8 Installing the M.2 Latch Follow these instructions to install the M.2 Latch. 1. Take out the M.2 Latch from the AK box. 2. Measure the length of the M.2 card and insert the latch into the appropriate hole. 3. Insert the M.2 Latch into the appropriate hole. http://www.tyan.com...
  • Page 50 4. Insert the M.2 card into the slot. Pull the latch to lock the M.2 card. 5. One latch can lock two M.2 cards. http://www.tyan.com...
  • Page 51: Installing Io Rail For Ocp Card

    2.1.9 Installing IO Rail for OCP Card Follow these instructions to install the IO rail for OCP Card. Here is a sample showing how to install the IO rail for the dual-port LAN card M7062-I599-2T. 1. Take out the OCP rail assembly from the AK box. 2.
  • Page 52: Rack Mounting

    Rails x 2 Screw x 2 2.2.1 Installing the Server in a Rack Follow these instructions to mount the GC68C-B8056 into an industry standard 19” rack. Note: Before mounting GC68C-B8056 in a rack, ensure that all internal components have been installed and that the unit has been fully tested.
  • Page 53: Installing Slide Rails To The Rack

    2.2.2 Installing Slide Rails to the Rack Take out the rails from the accessory kit. Push the white tab in the direction as the arrow shows to draw out the inner rail. Attach the inner rails to both sides of the chassis. Push the inner rails backward to lock in place.
  • Page 54 NOTE: Use a screwdriver to slightly push the latch open and then push the inner rail forwards to unlock. Attach the outer rail to the rack. Pull the latch open and align the square stud with the square hole on the rack rail. Please note that the square stud must be fully attached inside the square hole and then close the latch to lock.
  • Page 55 http://www.tyan.com...
  • Page 56 Front http://www.tyan.com...
  • Page 57: Rack Mounting The Server

    2.2.3 Rack mounting the Server Install the chassis. Draw out the rails half way and then slide the chassis into the rails. Must be done with at least 2 people. Properly place the chassis directly on the rack and install. Slide in the chassis half way to the lock position.
  • Page 58 http://www.tyan.com...
  • Page 59: Removing The Server From Rack

    2.2.4 Removing the Server from Rack Release the chassis ears by loosening the screws. Pull out the chassis half way to the lock position. Push the white locking tabs forward to slide the chassis all out from the rack. Caution: Remove the server from the rack carefully.
  • Page 60 NOTE http://www.tyan.com...
  • Page 61: Chapter 3: Replacing Pre-Installed Components

    Chapter 3: Replacing Pre-Installed Components Introduction This chapter explains how to replace the pre-installed components, including the S8056 Motherboard, M1724G68-FPB Front Panel Board, M1725G68-USB Board, M7136G68-L16-1F M7136G68-R16-1F Riser Cards, M1299G68A-BPE-12 HDD Backplane Boards, M1635T70E-D-PDB Power Distribution Board, System Fan and Power Supply etc. Disassembly Flowchart The following flowchart outlines the disassembly procedure.
  • Page 62: Removing The Cover

    Removing the Cover Follow Chapter 2.1.1 to remove the cover of GC68C-B8056. Replacing the Power Supply To replace the power supply follow these instructions. Press the latch as shown to pull out the power supply module. Replace a new single power and reinsert it into the power cage following the above steps in reverse.
  • Page 63: Replacing The Front Panel Board

    Replacing the Front Panel Board Follow these instructions to replace the M1724G68-FPB Front Panel Board. 1. Loosen 3 screws to release the front panel bezel from the chassis. 2. Loosen 2 screws to remove the front panel cage and bracket. 3.
  • Page 64: Front Panel Board Features

    3.5.1 Front Panel Board Features Front View Rear View M1724G68-FPB Front Panel Board Form Factor 33.5*21*1.6 mm (1) Signal Connector (J1) Integrated I/O (1) PWR Button (1) ID Button http://www.tyan.com...
  • Page 65: Replacing The Usb Board

    Replacing the USB Board Follow these instructions to replace the M1725G68-USB USB Board. 1. Loosen 3 screws to release the front USB bezel from the chassis. 2. Loosen 2 screws to remove the USB cage and bracket. 3. Disconnect the cable and unscrew the USB Board. 4.
  • Page 66: Usb Board Features

    3.6.1 USB Board Features Front View Rear View M1725G68-USB Front Panel Board Form Factor 31.9*19.4*1.6 mm (1) Signal Connector (J2) Integrated I/O (1) USB3.0 Connector http://www.tyan.com...
  • Page 67: Replacing The Hdd Backplane Board

    Replacing the HDD Backplane Board Follow these instructions to replace the M1299G68A-BPE-12 HDD Backplane Boards. 1. Disconnect all cables connected to the M1299G68A-BPE-12 HDD Backplane Board. 2. Use a screwdriver to unscrew the M1299G68A-BPE-12 HDD Backplane Board. 3. Lift up the HDD Backplane Board to get off the hook. 4.
  • Page 68: Hdd Bp Board Features

    3.7.1 HDD BP Board Features Front View Rear View M1299G68A-BPE-12 HDD Backplane Board Form Factor 435*38.3*2.6 mm PCI-E Gen4 12-pot NVMe U.2 BP Board (12) Hot-swap 2.5” NVMe U.2 SSD (2) ATX 2x4-pin Power Connector Integrated I/O (2) 5V connector for DOM (6) Slim-SAS connector (8) Fan connector (1) 2x15-pin Fan Control Connector (J31)
  • Page 69: Replacing Power Distribution Board

    Replacing Power Distribution Board Follow these instructions to replace the M1635T70E-D-PDB Power Distribution Board. 1. Pull the power supply modules slightly away from the chassis. Release cable ties and disconnect all cables from the Power Distribution Board. 2. Unscrew to replace the M1635T70E-D-PDB Power Distribution Board.
  • Page 70: Power Distribution Board Features

    3.8.1 Power Distribution Board Features M1635T70E-D-PDB Power Distribution Board Form Factor 167mm x 114mm x 2mm (2) Micro-fit 8P x2 (1) mini-fit 4Px2 Specifications (2) ATXPW4X1 POSx2 (2) mini-fit 4Px2 (1) mini-fit Power Connector 12Px2 http://www.tyan.com...
  • Page 71: Connector Definitions

    3.8.2 Connector Definitions Location Definition Power supply slot Power supply slot PSMI SMB Power 5x1 CPU1 ATX Power 4x2 CPU2 ATX Power 4x2 NVME ATX Power 4x2 SATA1 DC Power Jack 4x1 SATA2 DC Power Jack 4x1 PWR1 mini-fit Power Connector 12x 2 GPU1 micro-fit Power Connector PW10 GPU2 micro-fit Power Connector...
  • Page 72: Replacing The Riser Card

    Replacing the Riser Card Follow these instructions to replace the M7136G68-L16-1F and M7136G68-R16-1F Riser Cards. 1. Lift up the Riser Card Bracket from the chassis. Unscrew to replace with a new riser card M7136G68-L16-1F. 2. Unscrew to replace with a new riser card M7136G68-R16-1F. 3.
  • Page 73: Riser Card Features

    3.9.1 Riser card Features M7136G68-L16-1F Riser Card Form Factor W1.26” x D4.88”(W32mmxD124mm) PCI-E x16 Gen5 adapter card Specification (1) PCI-E x16 Gen5 slot support (1) PCI-E x16 Add-on card M7136G68-R16-1F Riser Card Form Factor W1.26” x D4.88”(W32mmxD124mm) PCI-E x16 Gen5 adapter card Specification (1) PCI-E x16 Gen5 slot support (1) PCI-E x16 Add-on card...
  • Page 74: Replacing The Fan

    3.10 Replacing the Fan Follow these instructions to replace the fan module. 1. Disconnect the fan PWR cable. 2. Lift up the fan module from the chassis. 3. Release the rubber screws and push pins from the fan module. Replace with a new fan and then insert the rubber screws and push pins.
  • Page 75 4. Place the new fan module into the chassis and reconnect the fan cable. Remember to tie cables after fan replacement. http://www.tyan.com...
  • Page 76: Replacing The Motherboard

    3.11 Replacing the Motherboard After removing all of the aforementioned components, follow these instructions to remove the motherboard from the chassis. Release the cable tie and disconnect all MB cables. http://www.tyan.com...
  • Page 77 Unscrew the motherboard to lift it up for replacement. http://www.tyan.com...
  • Page 78: Chapter 4: Mainboard Information

    Chapter 4: Mainboard Information You are now ready to install your motherboard. How to install our products right… the first time The first thing you should do is reading this user’s manual. It contains important information that will make configuration and setup much easier. Here are some precautions you should take when installing your motherboard: (1) Ground yourself properly before removing your motherboard from the antistatic bag.
  • Page 79: Board Image

    Board Image S8056 This picture is representative of the latest board revision available at the time of publishing. The board you receive may not look exactly like the above picture. http://www.tyan.com...
  • Page 80: Block Diagram

    Block Diagram S8056 Block Diagram http://www.tyan.com...
  • Page 81: Mainboard Mechanical Drawing

    Mainboard Mechanical Drawing http://www.tyan.com...
  • Page 82: Board Parts, Jumpers And Connectors

    Board Parts, Jumpers and Connectors This diagram is representative of the latest board revision available at the time of publishing. The board you receive may not look exactly like the above diagram. But for the DIMM number please refer to the above placement for memory installation. For the latest board revision, please visit our web site at http://www.tyan.com.
  • Page 83: Jumpers And Connectors

    Jumpers & Connectors Connectors 1. RJ45 LAN Port (LAN3) Dedicated 26 4-pin FAN Connector (SYS_FAN3) IPMI+ USB3.2 Gen1x2 2. VGA Header (VGA1) 27 MCIO SATA/NVME (CN10) 3. VGA Port + COM port 28 MCIO SATA/NVME (CN9) 4 RJ45 LAN Port (LAN2) 29 4-pin FAN Connector (SYS_FAN2) 5.
  • Page 84 LEDS BMC ALERT LED (D18) SATA & M.2 LED (D39) SYS_PWROK LED (D32) ID LED BMC heartbeat LED (D1_2) VIII PWR_GOOD LED (D52) PROCHOT LED (D26) PWROK LED (D57) PSU_ALERT LED (D31) CPU RESET LED (D58) Jumper Legend OPEN - Jumper OFF Without jumper cover CLOSED - Jumper ON With jumper cover...
  • Page 85 CPU0_FAN, SYS_FAN_1~5: 4-pin FAN Connector Signal P12V FAN_TACH FAN_PWM NOTE: FAN5 is design for OCP 3.0 card which will be hot in the S5 state. Therefore, it will still keep running on 30% duty when in S5 state. FPIO_2: Front Panel Connector Signal Signal PWRLED+...
  • Page 86 J62: TYAN Module Header Signal Signal VDD_33_DUAL ESPI_CS1 RESET# ALERT FAN_HD1: Fan Connector (Reserved for Barebone) Signal Signal TACH1 TACH6 TACH2 TACH7 TACH3 TACH8 TACH4 TACH9 TACH5 TACH10 PWM3 PWM2 TACH11 TACH12 PWM4 TACH13 TACH15 TACH14 TACH16 PWM5 PWM7 PWM0 USB3_FPIO1: USB3.2 Gen1 Header Signal Signal...
  • Page 87 SSATA_SGPIO0/1: SATA SGPIO Pin Header for SSATA0-1 Signal Signal SDATA OUT- SLOAD SCLOCK VCC3_AUX VGA1: Front Panel VGA Header Signal Signal VGA2_5V HD_VGA_R HD_VGA_G HD_VGA_B HD_VGA_DAT HD_VGA_HS HD_VGA_CLK HD_VGA_VS COM2: COM Port Header Signal Signal COM2_DCD COM2_DSR COM2_RXD COM2_RTS COM2_TXD COM2_CTS COM2_DTR COM2_NRI...
  • Page 88 IDLED_BTN1: Rear IO ID LED Button Signal Signal FP_IDLED_BTN_N PWR_BTN1: System Power Button Signal Signal PWR_BTN1 RST_BTN1: System Reset Button Signal Signal FP_RST_BTN_N J6/J7: BMC Debug Pin Header Signal Signal BMC_TXD2 TXD_OUT BMC_RXD2 RXD_OUT BMC_TXD5 BMC_RXD5 (Default) Pin1-2 closed: Normal Mode Pin2-3 closed: Debug Mode J8/J9: COM1 BIOS Debug Pin Header Signal...
  • Page 89 NGFF1: M.2 Connector Signal Signal VCC3 VCC3 VCC3_AUX M2_LED_N VCC3 VCC3 VCC3 VCC3 PCH_PE1_M2_1_RX_N PCH_PE1_M2_1_RX_P PCH_PE1_M2_1_TX_N PCH_PE1_M2_1_TX_P M2_SMB_CLK_R PCH_PE0_M2_0_RX_N M2_SMB_DAT_R PCH_PE0_M2_0_RX_P PCH_PE0_M2_0_TX_N M2_PERST_N_R PCH_PE0_M2_0_TX_P M2_2_PEWAKE_N CLK_100M_M2_DN CLK_100M_M2_DP PE_M.2_DETECT_N VCC3 VCC3 VCC3 http://www.tyan.com...
  • Page 90 CN1: MCIO0 Connector Signal Name Pin Pin Signal Name A1 B1 GND CPU0_PE4_RX_DN<7> A2 B2 CPU0_PE4_TX_DN<7> CPU0_PE4_RX_DP<7> A3 B3 CPU0_PE4_TX_DP<7> A4 B4 GND CPU0_PE4_RX_DN<6> A5 B5 CPU0_PE4_TX_DN<6> CPU0_PE4_RX_DP<6> A6 B6 CPU0_PE4_TX_DP<6> A7 B7 GND PE4_TYPEA A8 B8 CPU0_PE4_HDD0_SCL0 WAKE_NVME_N0 A9 B9 CPU0_PE4_HDD0_SDA0 A10 B10 GND CLK_100M_DB2000_CPU0_N A11 B11 RST_NVME0_CPU0_PERST_N...
  • Page 91 CN3/4/5/6/7/8/9/10: MCIO0 Connector Signal Name Pin Pin Signal Name A1 B1 GND CPU0_PE4_RX_DN<7> A2 B2 CPU0_PE4_TX_DN<7> CPU0_PE4_RX_DP<7> A3 B3 CPU0_PE4_TX_DP<7> A4 B4 GND CPU0_PE4_RX_DN<6> A5 B5 CPU0_PE4_TX_DN<6> CPU0_PE4_RX_DP<6> A6 B6 CPU0_PE4_TX_DP<6> A7 B7 GND PE4_TYPEA A8 B8 CPU0_PE4_HDD0_SCL0 WAKE_NVME_N0 A9 B9 CPU0_PE4_HDD0_SDA0 A10 B10 GND CLK_100M_DB2000_CPU0_N A11 B11 RST_NVME0_CPU0_PERST_N...
  • Page 92 J12: CPLD JTAG Connector (reserved) Signal Signal VDD_33_DUAL J66: Intrusion Header Signal SCM_CHASSIS_INTR_L J56: ESPI TPM Header Signal Signal SPI_TPM_CONN_CLK P3V3_AUX RST_PLTRST_TPM_CONN_N FM_TPM_CONN_PRSNT_R_N SPI_TPM_CONN_MOSI IRQ_TPM_CONN_PIRQ_N SPI_TPM_CONN_MISO P3V3 SPI_PCH_TPM_CONN_CS_N NC_TPM_PIN6 J3: CPLD force pwron options SEL Connector Signal Signal FORCE_PWRON_LVC3 Rpu 1k (Default) Pin1-2 closed: Normal Mode Pin2-3 closed: POWER ON...
  • Page 93 J33: reset sys/bmc SEL Connector Signal Signal COLD_RST_BTN_L FP_RST_BTN_JP_L FP_BMC_RST_BTN_N (Default) Pin1-2 closed: SYS RESET Pin2-3 closed: BMC RESET J75: Clear CMOS Jumper Signal Signal VDD_RTC P0_VDD_RTC (Default) Pin1-2 closed: Normal Mode Pin2-3 closed: Clear CMOS 3PHD_1: VRM SMBUS SEL Connector Signal Signal VR_I2C_CPU0_EN...
  • Page 94: Led Definitions

    LED Definitions http://www.tyan.com...
  • Page 95 Signal VDD_33_DUAL BMC_HW_FAULT_L i. D18 BMC ALERT LED State Description NORMAIL Orange BMC ALERT Signal VDD_33_DUAL SCM_SYS_PWROK- ii. D32 SYS_PWROK LED State Description NORMAIL Green SYSTEM POWER OK Signal VDD_33_DUAL BMC_HB_LED_L iii. D1_2 BMC heartbead LED State Description BMC not ready Green 1HZ BMC READY Signal...
  • Page 96 State Description POWER OFF Green SYSTEM POWER GOOD Signal VDD_5_DUAL P0_PWROK_LED- ix. D57 PWROK LED State Description CPU POWER OFF Green CPU POWER OK Signal VDD_5_DUAL P0_RESET_LED_L x. D58 CPU RESET LED State Description CPU RESET NORMAIL CPU RESET NOT SEND OUT http://www.tyan.com...
  • Page 97: Installing The Processor And Heat Sink

    Installing the Processor and Heat sink ® The S8056 supported Intel processors are listed in Section. Check our website at http://www.tyan.com for latest processor support. NOTE: MITAC TYAN is not liable for damage as a result of operating an unsupported configuration. ®...
  • Page 98 Align and install the carrier frame with package into the slot on the rail frame. NOTE: During installation, observe the following: make sure to push the carrier frame with package towards the end of the rail frame until it clicks in place. do not drop the carrier frame or touch the package pad to avoid component damage.
  • Page 99 Heat sink Installation After installing the processor, you will need to proceed to install the heat sink. The CPU heat sink will ensure that the processor do not overheat and continue to operate at maximum performance for as long as you own them. An overheated processor is dangerous to the motherboard.
  • Page 100 2. Use a T20 Torx screwdriver to tighten the heatsink screws in a sequential order(123456). NOTE: Always check with the manufacturer of the heat sink & processor to ensure that the thermal interface material is compatible with the processor and meets the manufacturer’s warranty requirements.
  • Page 101: Tips On Installing Motherboard In Chassis

    Tips on Installing Motherboard in Chassis Before installing your motherboard, make sure your chassis has the necessary motherboard support studs installed. These studs are usually metal and are gold in color. Usually, the chassis manufacturer will pre-install the support studs. If you are unsure of stud placement, simply lay the motherboard inside the chassis and align the screw holes of the motherboard to the studs inside the case.
  • Page 102 http://www.tyan.com...
  • Page 103: Installing The Memory

    Installing the Memory Before installing memory, ensure that the memory you have is compatible with the motherboard and processor. Check the TYAN Web site at http://www.tyan.com details of the type of memory recommended for your motherboard. DIMM Location http://www.tyan.com...
  • Page 104 DIMM Population/Channel DDR5 Frequency MT/s DIMM Type Genoa platforms DIMM 0 DIMM 1 14L 74mil low-DK PCB stackup RDIMM 4800 4000 4800 3600 3600 3DS RDIMM* 2SxR 4800 2SxR 2SxR 3600 *For 3DS RDIMM When x = 2 DIMM Ranks = 4 When x = 4 DIMM Ranks = 8 When x = 8...
  • Page 105 DIMM SLOT Silk screen DIMM SLOT Silk screen P0_DIMM_A0 P0_CHA_DIM0 P0_DIMM_G0 P0_CHG_DIM0 P0_DIMM_A1 P0_CHA_DIM1 P0_DIMM_G1 P0_CHG_DIM1 P0_DIMM_B0 P0_CHB_DIM0 P0_DIMM_H0 P0_CHH_DIM0 P0_DIMM_B1 P0_CHB_DIM1 P0_DIMM_H1 P0_CHH_DIM1 P0_DIMM_C0 P0_CHC_DIM0 P0_DIMM_I0 P0_CHI_DIM0 P0_DIMM_C1 P0_CHC_DIM1 P0_DIMM_I1 P0_CHI_DIM1 P0_DIMM_D0 P0_CHD_DIM0 P0_DIMM_J0 P0_CHJ_DIM0 P0_DIMM_D1 P0_CHD_DIM1 P0_DIMM_J1 P0_CHJ_DIM1 P0_DIMM_E0 P0_CHE_DIM0 P0_DIMM_K0...
  • Page 106 Recommended Memory Population Table Quantity of memory installed CPU Installed P0_CHA_DIM0 √ P0_CHA_DIM1 √ √ √ √ √ √ √ √ P0_CHB_DIM0 √ P0_CHB_DIM1 √ √ √ √ √ P0_CHC_DIM0 √ P0_CHC_DIM1 √ √ √ √ √ √ P0_CHD_DIM0 √ P0_CHD_DIM1 √...
  • Page 107: Memory Installation Procedure

    Memory Installation Procedure Follow these instructions to install memory modules into the S8056. Unlock the clips as shown in the illustration. Insert the memory module firmly into the socket by gently pressing down until it sits flush with the socket. Lock the clips to secure the memory module into place.
  • Page 108: Installing Add-In Cards

    Installing Add-In Cards Before installing add-in cards, it’s helpful to know if they are fully compatible with your motherboard. For this reason, we’ve provided the diagrams below, showing the slots that may appear on your motherboard. (1) PCIE#1 Gen.4/5 x 16 (PESLOT1) (1) PCIE#2 Gen.4/5 x 24 (PESLOT2) Simply find the appropriate slot for your add-in card and insert the card firmly.
  • Page 109: Connecting External Devices

    4.10 Connecting External Devices Connecting external devices to the motherboard is an easy task. The motherboard supports a number of different interfaces through connecting peripherals. See the following diagrams for the details. S8056GM2NE-2T S8056GME NOTE: 1. RJ45 (1Gb) LAN3 is from Realtek RTL8211F chipset. RJ45 (10Gb) LAN1/LAN2 are from Intel X710 chipset.
  • Page 110 Onboard LAN LED Color Definition The three (3) onboard Ethernet ports have green and yellow LEDs to indicate LAN status. The chart below illustrates the different LED states. 10Mbps/100Mbps/1Gbps/10Gbps LAN Link/Activity LED Scheme Left LED Right LED No Link Link Green 10Mbps Active...
  • Page 111: Installing The Power Supply

    4.11 Installing the Power Supply There are three (3) power connectors on your S8056 motherboard. The S8056 supports EPS 12V power supply. PWR1: ATX 24-pin Main Power Connector Signal Signal +3.3V_1 +3.3V_4 +3.3V_2 -12V COM_1 COM_4 +5V_1 PS-ON# COM_2 COM_5 +5V_2 COM_6 COM_3...
  • Page 112: Finishing Up

    4.12 Finishing Up Congratulations on making it this far! You have finished setting up the hardware aspect of your computer. Before closing up your chassis, make sure that all cables and wires are connected properly, especially IDE cables and most importantly, jumpers.
  • Page 113: Chapter 5: Bios Setup

    Chapter 5: BIOS Setup About the BIOS The BIOS is the basic input/output system, the firmware on the motherboard that enables your hardware to interface with your software. The BIOS determines what a computer can do without accessing programs from a disk. The BIOS contains all the code required to control the keyboard, display screen, disk drives, serial communications, and a number of miscellaneous functions.
  • Page 114 5.1.2 Getting Help Pressing [F1] will display a small help window that describes the appropriate keys to use and the possible selections for the highlighted item. To exit the Help Window, press [ESC] or the [Enter] key again. 5.1.3 In Case of Problems If you have trouble booting your computer after making and saving the changes with the BIOS setup program, you can restart the computer by holding the power button down until the computer shuts off (usually within 4 seconds);...
  • Page 115: Main

    Main In this section, you can alter general features such as the date and time. Note that the options listed below are for options that can directly be changed within the Main Setup screen. System Language Choose the system default language. English / Simplified Chinese / Japanese System Date Set the Date.
  • Page 116: Advanced

    Advanced This section facilitates configuring advanced BIOS options for your system. NOTE: This is a sample screenshot of the Advanced Menu. The HII network drivers displayed here depend on the card(s) you installed and the functions you enabled. Network Stack Configuration Network Stack Settings S5 RTC Wake Settings Enable system to wake from S5 using RTC alarm...
  • Page 117 Super IO Configuration System Super IO Chip Parameters. Hardware Health Configuration Hardware Health Configuration PCI Subsystem Settings PCI, PCI-X and PCI Express Settings NVMe Configuration NVMe Device Information Trusted Computing Trusted Computing settings. CSM Configuration CSM Configuration, Enable/Disable Option ROM execution setting, etc Redfish Host Interface Settings Redfish Host Interface Parameters Tls Auth Configuration...
  • Page 118 5.3.1 Network Stack Configuration Network Stack Enable/Disable UEFI Network Stack Disabled / Enabled NOTE: When Network Stack was set to Enabled, the following item will appear. IPv4 PXE Support Enable/Disable IPv4 PXE boot support. If disabled, IPv4 PXE boot support will not be available.
  • Page 119 IPv6 HTTPs Support Enable/Disable IPv6 HTTPs boot support. If disabled, IPv6 HTTPS boot support will not be available. Disabled / Enabled PXE boot wait time Wait time in seconds to press ESC key to abort the PXE boot. Use either +/- or numeric keys to set the value.
  • Page 120 5.3.2 S5 RTC Wake Settings Wake system from S5 Enable or disable system wake on alarm event. Select Fixed time, system will wake on the hr::min::sec specified. Select dynamic time, system will wake on the current time+ increase minute(s) Disabled / Fixed Time / Dynamic Time When Wake system from S5 is set to [Fixed Time] Wake up hour Select 0-23.
  • Page 121 5.3.3 Serial Port Console Redirection COM1/COM2 Console Redirection Console redirection enable or disable. Disabled / Enabled Legacy Console Redirection Legacy Console Redirection Settings Serial Port for Out-Of-Band Management/Windows Emergency Services (EMS) Console Redirection Console redirection enable or disable. Disabled / Enabled Console Redirection Settings The settings specify how the host computer (which the user is using) will exchange data.
  • Page 122 5.3.3.1 COM1 Console Redirection Settings Terminal Type Emulation: ANSI: Extended ASCII char set. VT100: ASCII char set. VT100+: Extends VT100 to support color function keys, etc. VT-UTF8: Uses UTF8 encoding to map Unicode chars onto 1 or more bytes. VT-UTF8 / VT100 / VT100+ / ANSI Bits per Second Select serial port transmission speed.
  • Page 123 Stop Bits Stop bits indicate the end of a serial data packet. (A start bit indicates the beginning). The standard setting is 1 stop bit. Communication with slow devices may require more than 1 stop bit. 1 / 2 Flow Control Flow Control can prevent data loss from buffer overflow.
  • Page 124 5.3.3.2 COM2 Console Redirection Settings Terminal Type Emulation: ANSI: Extended ASCII char set. VT100: ASCII char set. VT100+: Extends VT100 to support color function keys, etc. VT-UTF8: Uses UTF8 encoding to map Unicode chars onto 1 or more bytes. VT100 / VT100+ / VT-UTF8 / ANSI Bits per Second Select serial port transmission speed.
  • Page 125 Stop Bits Stop bits indicate the end of a serial data packet. (A start bit indicates the beginning). The standard setting is 1 stop bit. Communication with slow devices may require more than 1 stop bit. 1 / 2 Flow Control Flow Control can prevent data loss from buffer overflow.
  • Page 126 5.3.3.3 Legacy Console Redirection Settings Redirection COM Port Select a COM port to display redirection of Legacy OS and Legacy OPROM Messages COM1 / COM2 Resolution On Legacy OS, the Number of Rows and Columns supported redirection 80x24 / 80x25 Redirect After POST when Bootloader is selected, then Legacy Console Redirection is disabled before booting to legacy OS, when Always Enable is selected, then Legacy Console...
  • Page 127 5.3.3.4 Serial Port for Out-Of-Band Management/Windows Emergency Services (EMS) Console Redirection Settings Out-of Band Mgmt Port Microsoft Windows Emergency Management Services (EMS) allows for remote management of a Windows Server OS through a serial port. COM1 / COM2 Terminal Type VT-UTF8 is the preferred terminal type for out-of-band management.
  • Page 128 Flow Control Flow Control can prevent data loss from buffer overflow. When sending data, if the receiving buffers are full, a ‘stop’ signal can be sent to stop the data flow. Once the buffers are empty, a ‘start’ signal can be sent to restart the flow. Hardware flow control uses two wires to send start/stop signal.
  • Page 129 5.3.4 PCIe Device Configuration Option ROM Dispatch Policy Option ROM Dispatch Policy settings. PCIe Slot Bifurcation PCIe Slot Bifurcation settings. PCIe Slot Speed PCIe Slot Speed settings. http://www.tyan.com...
  • Page 130 5.3.4.1 Device Class Option ROM Dispatch Policy LAN1 (X710) Enable or Disable LAN1 Option Rom Enabled / Disabled LAN2 (X710) Enable or Disable LAN2 Option Rom Enabled / Disabled PESLOT1x16 Option ROM Enable or Disable Option ROM execution for selected Slot. Enabled / Disabled PESLOT2 Option ROM Enable or Disable Option ROM execution for selected Slot.
  • Page 131 5.3.4.2 PCIe Slot Bifurcation PESLOT1x16 Selects PCIE port Bifurcation for PESLOT1x16 slot. x16 / x8x8 / x4x4x4x4 PESLOT2 Selects PCIE port Bifurcation for PESLOT2 slot. x16 / x8x8 / x4x4x4x4 / SATAx8/SATAx8 OCP3.0 Selects PCIE port Bifurcation for OCP3.0 slot x16 / x8x8 / x4x4x4x4 http://www.tyan.com...
  • Page 132 5.3.4.3 PCIe Slot Speed PESLOT1x16 Maximum Link Speed for PESLOT x16 slot. Auto / GEN1 (2.5 GT/s) / GEN2 (5 GT/s) / GEN3 (8 GT/s) / GEN4 (16 GT/s) / GEN5 (32GT/s) PESLOT2 Maximum Link Speed for PESLOT2 slot. Auto / GEN1(2.5 GT/s) / GEN2(5 GT/s) / GEN3(8 GT/s) / GEN4(16 GT/s) / GEN5 (32GT/s) OCP3.0 Maximum Link Speed for OCP3.0 slot.
  • Page 133 5.3.5 USB Configuration Legacy USB Support Enables USB legacy support. AUTO option disables legacy support if no USB devices are connected. DISABLE option will keep USB devices available only for EFI applications. Enabled / Disabled / Auto XHCI Hand-off This is a workaround for OSes without XHCI hand-off support. The XHCI ownership change should be claimed by XHCI driver.
  • Page 134 USB transfer time-out The time-out value for Control, Bulk and Interrupt transfers. 1 sec / 5 sec / 10 sec / 20 sec Device reset time-out USB mass storage device Start Unit command time-out. 10 sec / 20 sec / 30 sec / 40 sec Device power-up delay Maximum time the device will take before it properly reports itself to the Host Controller.
  • Page 135 5.3.6 Onboard Device Configuration Onboard VGA Enable/Disable ASPEED VGA Disabled / Enabled LAN (X710) LAN Enable/Disable control function. Disabled / Enabled Primary Display Select active Video type. Onboard / External NMI Button Enable or disable NMI button. Disabled / Enabled Clock Spread Spectrum Enable/Disable CG1_PLL Spread Spectrum Disabled / Enabled...
  • Page 136 5.3.7 Super IO Configuration Serial Port 1 Configuration Set Parameters of serial Port 1 (COMA) Serial Port 2 Configuration Set Parameters of serial Port 2 (COMB) http://www.tyan.com...
  • Page 137 5.3.7.1 Serial Port 1 Configuration Serial Port Select an optimal settings for Super IO Device. Disabled / Enabled NOTE: Serial Port has set to Enabled, the following items will be appear. Change Settings Allows the user to change the device resource settings. New settings will be reflected on this setup page after system restarts.
  • Page 138 5.3.7.2 Serial Port 2 Configuration Serial Port Enable or Disable Serial Port (COM). Disabled / Enabled NOTE: Serial Port has set to Enabled, the following items will be appear. Change Settings Allows the user to change the device resource settings. New settings will be reflected on this setup page after system restarts.
  • Page 139 5.3.8 Hardware Health Configuration Fan Speed Control Fan Speed Control help. Automatic / Manual / Full Speed BMC Alert Beep Enable/Disable BMC Alert Beep. On / Off PMBus support PMBus Support Disabled / Enabled Number of PSU (available if PMBus support is set to [Enabled]) User can select PSU number for needed 1 / 2 http://www.tyan.com...
  • Page 140 5.3.8.1 Sensor Data Register Monitoring When you enter the Sensor Data Register Monitoring submenu, you will see the following dialog window pop out. Please wait 8~10 seconds. NOTE: SDR can not be modified. Read only. http://www.tyan.com...
  • Page 141 http://www.tyan.com...
  • Page 142 http://www.tyan.com...
  • Page 143 5.3.9 PCI Subsystem Settings Above 4G Decoding Enables or Disables 64bit capable Devices to be decoded in Above 4G Address Space(Only if System supports 64 bit PCI Decoding). Enabled / Disabled SR-IOV Support If system has SR-IOV capable PCIe devices, this option Enables or Disables Single Root IO virtualization Support Enabled / Disabled PCI Express Settings...
  • Page 144 5.3.9.1 PCI Express Subsystem Maximum Payload Set Maximum Payload of PCI Express Device or allow System BIOS to select the value. Auto / 128 Bytes / 256 Bytes / 512 Bytes / 1024 Bytes / 2048 Bytes / 4096 Bytes http://www.tyan.com...
  • Page 145 5.3.10 NVMe Configuration Read only. http://www.tyan.com...
  • Page 146 5.3.11 Trusted Computing Security Device Support Enables or disables BIOS support for security device. O.S. will not show Security device. O.S. will not show Security Device. TCG EFI protocol and INT1A interface will not be available. Enabled / Disabled http://www.tyan.com...
  • Page 147 5.3.12 CSM Configuration CSM support Enable/Disable CSM Support Enabled / Disabled NOTE: When CSM support is set to [Disabled], the following items are hidden. Option ROM Messages Set display mode for Option ROM Force BIOS / Keep Current Network Controls the execution of UEFI and legacy PXE OpROM UEFI / Legacy Storage Controls the execution of UEFI and legacy PXE OpROM...
  • Page 148 Other PCI devices Determines OpRom execution policy for devices other than network, storage, or video UEFI / Legacy http://www.tyan.com...
  • Page 149 5.3.13 Redfish Host Interface Settings Redfish Enable/Disable AMI Redfish. Disabled / Enabled http://www.tyan.com...
  • Page 150 5.3.14 Tls Auth Configuration Server CA Configuration Press <Enter> to configure Server CA. http://www.tyan.com...
  • Page 151 5.3.14.1 Server CA Configuration Enroll Cert Press <Enter> to enroll cert. Delete Cert Press <Enter> to delete cert. http://www.tyan.com...
  • Page 152 5.3.14.1.1 Enroll Cert Configuration Enroll Cert Using File Enroll Cert Using File Cert GUID Input digit character in 11111111-2222-3333-4444-1234567890ab format. Commit Changes and Exit Commit Changes and Exit Discard Changes and Exit Discard Changes and Exit http://www.tyan.com...
  • Page 153 5.3.14.1.2 Delete Cert Configuration FEXXXXXX-XXXX-XXXX-XXXX-XXXXXXXXXX GUID for CERT Disabled / Enabled http://www.tyan.com...
  • Page 154 5.3.15 ISCSI Initiator Configuration Please follow the instructions to initiate the iSCSI function. Step 1. Select Advanced  CSM Configuration  Network  [UEFI]. Step 2. Select Advanced  Network Stack Configuration  Network Stack  [Enabled] Step 3. Save changes and reboot. Attempt Priority Change the priority using +/- keys.
  • Page 155 5.3.15.1 Attempt Priority Attempt Priority Change the priority using +/- keys. Use arrow keys to select the attempt then press +/- to move the attempt up/down in the attempt order list. Host Attempt / Redfish Attempt Commit Changes and Exit Commit Changes and Exit.
  • Page 156 5.3.15.2 Host iSCSI Configuration iSCSI Initiator Name The worldwide unique name of iSCSI Initiator. Only IQN format is accepted. Enter [iqn.xxx]. xxx ranges from 4 to 223. For example: Enter [iqn.111] http://www.tyan.com...
  • Page 157 Add an Attempt Add an Attempt. Delete Attempts Delete one or more attempts. Change Attempt Order Change the order of Attempts using +/- keys. Use arrow keys to select the attempt then press +/- to move the attempt up/down in the attempt order list. http://www.tyan.com...
  • Page 158 5.3.15.3 Add an Attempt Read only. http://www.tyan.com...
  • Page 159 5.3.15.3.1 MAC xx:xx:xx:xx:xx:xx iSCSI Mode Disabled, Enabled, Enabled for MPIO. Disabled / Enabled / Enabled for MPIO Internet Protocol Initiator IP address is system assigned in IP6 mode. In Autoconfigure mode, iSCSI driver will attempt to connect iSCSI target via IPv4 stack, if failed then attempt IPv6 stack.
  • Page 160 Configure ISID OUI-format ISID in 6 bytes, default value is derived from MAC address. Only last 3 bytes are configurable. Example: update 0ABBCCDDEEFF to OABBCCF07901 by input F07901. Enable DHCP Enable DHCP. Disabled / Enabled Initiator IP Address Enter IP address in dotted-decimal notation. Initiator Subnet Mask Enter IP address in dotted-decimal notation.
  • Page 161 5.3.15.3.2 MAC xx:xx:xx:xx:xx:xx iSCSI Mode Disabled, Enabled, Enabled for MPIO. Disabled / Enabled / Enabled for MPIO Internet Protocol Initiator IP address is system assigned in IP6 mode. In Autoconfigure mode, iSCSI driver will attempt to connect iSCSI target via IPv4 stack, if failed then attempt IPv6 stack.
  • Page 162 Enable DHCP Enable DHCP. Disabled / Enabled Initiator IP Address Enter IP address in dotted-decimal notation. Initiator Subnet Mask Enter IP address in dotted-decimal notation. Gateway Enter IP address in dotted-decimal notation. Target Name The worldwide unique name of the target. Only iqn. format is accepted. Range is from 4 to 223 iqn.
  • Page 163 5.3.15.4 Delete Attempts Commit Changes and Exit Commit Changes and Exit. Discard Changes and Exit Discard Changes and Exit. http://www.tyan.com...
  • Page 164 5.3.15.5 Change Attempt Order Commit Changes and Exit Commit Changes and Exit. Discard Changes and Exit Discard Changes and Exit. http://www.tyan.com...
  • Page 165 5.3.16 VLAN Configuration Enter Configuration Menu Press ENTER to enter configuration menu for VLAN configuration. http://www.tyan.com...
  • Page 166 5.3.16.1 Enter Configuration Menu VLAN ID VLAN ID of new VLAN or existing VLAN, valid value is 0~4094 Priority 802.1Q Priority, valid value is 0~7 Add VLAN Create a new VLAN or update existing VLAN Remove VLAN Remove selected VLANs http://www.tyan.com...
  • Page 167 5.3.17 MAC: xxxxxxxxxxxx-IPv4 Network Configured Indicate whether network address configured successfully or not. Disabled / Enabled NOTE: When Configured was set to [Enabled], the following items will be available. Enable DHCP Indicate whether network address configured successfully or not. Disabled / Enabled Local IP Address Enter IP address in dotted-decimal notation.
  • Page 168 Enter DNS Servers in dotted-decimal notation. Example:192.168.10.8 192.168.10.9 Save Changes and Exit Save Changes and Exit http://www.tyan.com...
  • Page 169 5.3.18 MAC: xxxxxxxxxxxx -IPv6 Network Enter Configuration Menu Press ENTER to enter configuration menu for VLAN configuration. http://www.tyan.com...
  • Page 170 5.3.18.1 Enter Configuration Menu Interface ID The 64 bit alternative interface ID for the device. The string is colon separated. e.g. ff:dd:88:66:cc:1:2:3 DAD Transmit Count The number of consecutive Neighhor Solicatation message sent while performing Duplicate Address Detection on a tentative address. A value of zero indicates that duplicate address detection is not performed.
  • Page 171 5.3.19 Intel® Ethernet Network Adapter X710-TL Firmware Image Properties View device firmware version information. NIC Configuration Click to configure the network device port. Blink LEDs Blink LEDs for a duration up to 15 seconds. http://www.tyan.com...
  • Page 172 5.3.19.1 Firmware Image Properties Option ROM version / Unique NVM/EEPROM ID / NVM Version Read only. http://www.tyan.com...
  • Page 173 5.3.19.2 NIC Configuration Link Speed Specifies the port speed used for the selected boot protocol. Auto Negotiated / 10 Mbps Half / 10Mbps Full / 100Mbps Half / 100Mbps Full Wake On LAN Enables power on of the system via LAN. Note that configuring Wake on LAN in the operating system does not change the value of this setting, but does override the behavior of Wake on LAN in OS controlled power states.
  • Page 174 5.3.20 VLAN Configuration Enter Configuration Menu Press ENTER to enter configuration menu for VLAN configuration. http://www.tyan.com...
  • Page 175 5.3.20.1 Enter Configuration Menu VLAN ID VLAN ID of new VLAN or existing VLAN, valid value is 0~4094 Priority Q Priority, valid value is 0~7 Add VLAN Create a new VLAN or update existing VLAN Remove VLAN Remove selected VLANs http://www.tyan.com...
  • Page 176 5.3.21 MAC: xxxxxxxxxxxx-IPv4 Network Configured Indicate whether network address configured successfully or not. Disabled / Enabled NOTE: When Configured was set to Enabled, the following items will be available to set up. Enable DHCP Indicate whether network address configured successfully or not. Disabled / Enabled Local IP Address Enter IP address in dotted-decimal notation.
  • Page 177 Local DNS Servers Enter DNS Servers in dotted-decimal notation. Example:192.168.10.8 192.168.10.9 Save Changes and Exit Save Changes and Exit http://www.tyan.com...
  • Page 178 5.3.22 MAC: xxxxxxxxxxxx -IPv6 Network Enter Configuration Menu Press ENTER to enter configuration menu for VLAN configuration. http://www.tyan.com...
  • Page 179 5.3.22.1 Enter Configuration Menu Interface ID The 64 bit alternative interface ID for the device. The string is colon separated. e.g. ff:dd:88:66:cc:1:2:3 DAD Transmit Count The number of consecutive Neighhor Solicatation message sent while performing Duplicate Address Detection on a tentative address. A value of zero indicates that duplicate address detection is not performed.
  • Page 180 5.3.23 Intel® Ethernet Network Adapter X710-TL Firmware Image Properties View device firmware version information. NIC Configuration Click to configure the network device port. Blink LEDs Blink LEDs for a duration up to 15 seconds. http://www.tyan.com...
  • Page 181 5.3.23.1 Firmware Image Properties Option ROM version / Unique NVM/EEPROM ID / NVM Version Read only. http://www.tyan.com...
  • Page 182 5.3.23.2 NIC Configuration Link Speed Specifies the port speed used for the selected boot protocol. Auto Negotiated / 10 Mbps Half / 10Mbps Full / 100Mbps Half / 100Mbps Full Wake On LAN Enables power on of the system via LAN. Note that configuring Wake on LAN in the operating system does not change the value of this setting, but does override the behavior of Wake on LAN in OS controlled power states.
  • Page 183 5.3.24 VLAN Configuration Enter Configuration Menu Press ENTER to enter configuration menu for VLAN configuration. http://www.tyan.com...
  • Page 184 5.3.24.1 Enter Configuration Menu VLAN ID VLAN ID of new VLAN or existing VLAN, valid value is 0~4094 Priority Q Priority, valid value is 0~7 Add VLAN Create a new VLAN or update existing VLAN Remove VLAN Remove selected VLANs http://www.tyan.com...
  • Page 185 5.3.25 MAC: xxxxxxxxxxxx-IPv4 Network Configured Indicate whether network address configured successfully or not. Disabled / Enabled NOTE: When Configured was set to Enabled, the following items will be available to set up. Enable DHCP Indicate whether network address configured successfully or not. Disabled / Enabled Local IP Address Enter IP address in dotted-decimal notation.
  • Page 186 Local DNS Servers Enter DNS Servers in dotted-decimal notation. Example:192.168.10.8 192.168.10.9 Save Changes and Exit Save Changes and Exit http://www.tyan.com...
  • Page 187 5.3.26 MAC: xxxxxxxxxxxx -IPv6 Network Enter Configuration Menu Press ENTER to enter configuration menu for VLAN configuration. http://www.tyan.com...
  • Page 188 5.3.26.1 Enter Configuration Menu Interface ID The 64 bit alternative interface ID for the device. The string is colon separated. e.g. ff:dd:88:66:cc:1:2:3 DAD Transmit Count The number of consecutive Neighhor Solicatation message sent while performing Duplicate Address Detection on a tentative address. A value of zero indicates that duplicate address detection is not performed.
  • Page 189: Cpu

    CPU Configuration CPU Configuration Parameters http://www.tyan.com...
  • Page 190 5.4.1 CPU Configuration SVM Mode Enable/disable CPU Virtualization Enabled / Disabled SMEE Control secure memory encryption enable Enabling both SMEE and SME-Mk is not supported. Results in #GP Enabled / Disabled CPU0 Information View Information related to CPU0 http://www.tyan.com...
  • Page 191 5.4.1.1 CPU0 Information Read only. http://www.tyan.com...
  • Page 192: Chipset

    Chipset PCIe Compliance Mode PCIe Link Compliance Mode. Disabled / Enabled North Bridge North Bridge Parameters. AMD CBS AMD CBS Setup Page. AMD PBS AMD PBS Setup Page. http://www.tyan.com...
  • Page 193 5.5.1 North Bridge North Bridge Configuration Memory Information Total Memory: xxxxx MB CPU 0 Information View Memory Information related to CPU 0 http://www.tyan.com...
  • Page 194 5.5.1.1 CPU 0 Information Read only. http://www.tyan.com...
  • Page 195 5.5.2 AMD CBS CPU Common Options CPU Common Parameters DF Common Options DF Common Parameters UMC Common Options UMC Common Parameters NBIO Common Options NBIO Common Parameters FCH Common Options FCH Common Parameters Soc Miscellaneous Control Soc Miscellaneous Control parameters http://www.tyan.com...
  • Page 196 5.5.2.1 CPU Common Options CCD/Core/Thread Enablement CCD/Core/Thread Enablement. Prefetcher settings Prefetcher settings. Platform First Error Handling Enable/Disable PFEH, cloak individual banks, and mask deferred error interrupts from each bank. Enabled / Disabled / Auto Core Performance Boost Disable CPB. Disabled / Auto Global C-state Control Controls IO based C-state generation and DF C-states.
  • Page 197 SEV-ES ASID Space Limit SEV-ES and SNP guests must use ASIDs in the range 1 through (this value -1). SEV guests must use ASIDs in the range of this value through 1006. To have all ASIDs support SEV-ES or SNP guests, set this value to 1007. The default is 1: all SEV guests and no SEV-ES or SNP guests.
  • Page 198 5.5.2.1.1 CCD/Core/ Thread Enablement CCD Control Sets the number of CCDs to be used. Once this option has been used to remove any CCDs, a POWER CYCLE is required in order for future selections to take effect. Auto / 2 CCDs / 4 CCDs / 6 CCDs / 8 CCDs / 10 CCDs Core control Sets the number of Cores to be used.
  • Page 199 5.5.2.1.2 Prefetcher Settings L1 Stream HW Prefetcher Option to Enable | Disable L1 Stream HW Prefetcher Disabled / Enabled / Auto L2 Stream HW Prefetcher Option to Enable | Disable L2 Stream HW Prefetcher Disabled / Enabled / Auto http://www.tyan.com...
  • Page 200 5.5.2.2 DF Common Options Memory Addressing Memory Addressing. ACPI ACPI. PSP error injection support Enable EINJ support False / True http://www.tyan.com...
  • Page 201 5.5.2.2.1 Memory Addressing NUMA nodes per socket Specifies the number of desired NUMA nodes per socket. Zero will attempt to interleave the two sockets together. NPS1 / NPS2 / NPS4 Memory interleaving Allows for disabling memory interleaving. Note that NUMA nodes per socket will be honored regardless of this setting.
  • Page 202 5.5.2.2.2 ACPI ACPI SRAT L3 Cache As NUMA Domain Enabled: Each CCX in the system will be declared as a separate NUMA domain. Disabled: Memory Addressing \ NUMA nodes per socket will be declared. Disabled / Enabled / Auto http://www.tyan.com...
  • Page 203 5.5.2.3 UMC Common Options DDR Addressing Options DDR addressing parameters DDR Timing Configuration DDT Timing parameters DDR RAS DDR RAS parameters DDR Security DDR Security parameters http://www.tyan.com...
  • Page 204 5.5.2.3.1 DDR Addressing Options Chipselect Interleaving Interleave memory blocks across the DRAM chip selects for node 0. Disabled / Auto BankSwapMode BankSwapMode value: 0=Disabled, 1= SwapCPU Auto / Disabled / Swap CPU http://www.tyan.com...
  • Page 205 5.5.2.3.2 DRAM Time Configuration Active Memory Timing Settings Active Memory Timing Settings. Auto / Enabled Memory Target Speed Specifies the memory target speed in MT/s. Auto / DDR3200 / DDR3600 / DDR4000 / DDR4400 / DDR4800 / DDR5200 / DDR5600 http://www.tyan.com...
  • Page 206 5.5.2.3.3 DDR RAS Data Poisoning Enable poison data creation on uncorrectable DDR DRAM ECC errors and poison propagation to CPU cores and caches. Requires ECC memory. When FALSE, a fatal error event will occur on DDR ECC errors sets UMC_CH::EccCtrl[UcFatalEn] when MC_CH::EccCtrl[WrEccEn] is set. Disabled / Enabled / Auto DRAM Boot Time Post Package Repair Enable or Disable DRAM Boot Time Post Package Repair.
  • Page 207 Disable Memory Error Injection 0=Enable. 1=Disable. Specifies UMC error injection configuration writes are disabled. True: UMC::CH::MiscCfg[DisErrInj]=1 False / True / Auto DRAM Scrubbers DRAM Scrubbers. ECC Configuration ECC Configuration. DRAM Corrected Error Counter Enable Configure DRAM Corrected Error Counter function. Only meaningful when PcdAmdCcxCfgPFEHEnable is TRUE.
  • Page 208 5.5.2.3.3.1 DRAM Scrubbers DRAM ECS Mode 0=AutoECS Mode, 1=ManualECS mode. AutomaticECS / ManualECS / Auto / DisableECS DRAM Redirect Scrubber Enable Enable/Disable Dram Redirect Scrubber. Disabled / Enabled / Auto DRAM Scrub Redirection Limit Dram ECC Scrub Redirection Limit: 0=8 scrubs, 1=4 scrubs, 2=2 scrubs, 3=1 scrub. 8 Scrubs / 4 Scrubs / 2 Scrubs / 1 Scrub / Auto DRAM Scrub Time Provide a value that is the number of hours to scrub memory.
  • Page 209 ETC_4 / ETC_16 / ETC_64 / ETC_256 / ETC_1024 / ETC_4096 / Auto DRAM ECS Count Mode 0: RowCount Mode 1: CodeWord Mode 0xFF: Auto – ABL decides default as CodeWord Mode. Row Count Mode / Code Word Count Mode / Auto DRAM AutoEcs during Self Refresh 0: AutoEcs Disabled 1: AutoEcs Enabled...
  • Page 210 5.5.2.3.3.2 ECC Configuration DRAM ECC Symbol Size DRAM ECC Symbol Size (x4/x16) – UMC_CH::EccCtrl[EccSymbolSize16, EccSymbolSize]. x4 / x16 / Auto DRAM ECC Enable Use this option to enable / disable DRAM ECC. Auto will set ECC to enable. Disabled / Enabled / Auto DRAM UECC Retry DRAM UECC Retry.
  • Page 211 5.5.2.3.4 DDR Security TSME Transparent Secure Memory Encryption. Auto / Disabled / Enabled Data Scramble Data Scrambling. Disabled / Enabled http://www.tyan.com...
  • Page 212 5.5.2.4 NBIO Common Options IOMMU Enable/Disable IOMMU. Disabled / Enabled / Auto ACS Enable AER must be enabled for ACS enable to work. Enabled / Disabled / Auto PCIe ARI Support Enables Alternative Routing-ID Interpretation. Disabled / Enabled / Auto PCIe Ten Bit Tag Support Enables PCIe ten bit tags for supported devices.
  • Page 213 SMU Common Options SMU Common Options. NBIO RAS Common Options NBIO RAS Common Options. Enable AER Cap Enables Advanced Error Reporting Capability. Enabled / Disabled / Auto NVMe Hotplug Mode System would reset when the mode changed. Enterprise SSD Mode / Server Express Mode http://www.tyan.com...
  • Page 214 5.5.2.4.1 SMU Common Options TDP Control Auto=Use the fused TDP Manual=User can set customized TDP Manual / Auto TDP (available if TDP Control is set to [Manual]) TDP [W] (in decimal). PPT Control Auto=Use the fused PPT Manual=User can set customized PPT Manual / Auto PPT (available if PPT Control is set to [Manual]) PPT [W] (in decimal) Determinism Control...
  • Page 215 Determinism Enable [0=Power; 1=Performance] Power / Performance APBDIS 0=not APBDIS (mission mode) 1=APBDIS 0 / 1 / Auto DfPstate DfPstate index to set when APBDIS=1 [0-2] Power Profile Selection DF Pstate selection in the profile policy is overridden by the pstate range BIOS option or the APB_DIS BIOS option if either one is selected.
  • Page 216 5.5.2.4.2 NBIO RAS Common Options NBIO RAS Control (0) Disabled, (1) MCA Disabled / MCA / Auto Egress Poison Severity High Each bit set to 1 enables HIGH severity on the associated IOHC egress port. A bit of 0 indicates LOW severity. 30011 Egress Poison Severity Low Each bit set to 1 enables HIGH severity on the associated IOHC egress port.
  • Page 217 NBIO SyncFlood Reporting This value may be used to enable SyncFlood will be reported to APML. When set to TRUE SyncFlood will be reported to APML. When set to FALSE that reporting will be disabled. Enabled / Disabled / Auto Egress Poison Mask High These set the enable mask for masking of errors logged in EGRESS_POISON_STATUS.
  • Page 218 ACS RAS Request Value No help string. Direct Request Access Enable / Request Blocking Enabled / Request Redirect Enabled / Auto NBIO Poison Consumption NBIO Poison Consumption. Auto / Enabled / Disabled Sync Flood on PCIe Fatal Error When ‘Sync Flood on PCIe Fatal Error’ is True, PcdAmdPciesSyncFloodOnFatal should be set to True.
  • Page 219 5.5.2.5 FCH Common Options Ac Power Loss Options Ac Power Loss Options. FCH RAS Options FCH RAS Options. SATA Configuration SATA Devices Information. http://www.tyan.com...
  • Page 220 5.5.2.5.1 AC Power LOSS Options AC Loss Control Select AC Loss Control Method. Power Off / Power On / Last State http://www.tyan.com...
  • Page 221 5.5.2.5.2 FCH RAS Options Reset After Sync-Flood Enable AB to forward downstream sync-flood message to system controller. Enabled / Disabled / Auto http://www.tyan.com...
  • Page 222 5.5.2.5.3 SATA Configuration Read only. http://www.tyan.com...
  • Page 223 5.5.2.6 Soc Miscellaneous Control ABL Console Out Control Enable: Enable ConsoleOut Function for ABL. Disable: Disable ConsoleOut Function for ALB. Auto: Keep default behavior. Disabled / Enabled / Auto PSP error injection support Enable EINJ support. False / True http://www.tyan.com...
  • Page 224 5.5.3 AMD PBS AMD CPM RAS related settings. http://www.tyan.com...
  • Page 225 5.5.3.1 Platform First Error Handling Initialize the PCIe AER Uncorrected Error Severity registers of Root Port. 7EF6030 PCIe Device UnCorr Error Sev Reg Initialize the PCIe AER Uncorrected Error Severity registers of PCIe Device. 7EF6030 DRAM Hard Post Package Repair This feature allows spare DRAM rows to replace malfunctioning rows via an in-field repair mechanism.
  • Page 226 PCIe Device Corr Err Mask Reg Initialize the PCIe AER Corrected Error Mask register of PCIe Device. 1000 PCIe Device Uncorr Err Mask Reg Initialize the PCIe AER Uncorrected Error Mask register of PCIe Device. 100000 http://www.tyan.com...
  • Page 227: Server Management

    Server Management BMC Logo Enable or Disable BMC logo Disabled / Enabled System Event Log Press<Enter> to change the SEL event log configuration. BMC network configuration Configure BMC network parameters BMC User Settings Press<Enter> to Add. Delete and Set Privilege level for users. http://www.tyan.com...
  • Page 228 5.6.1 System Event Log SEL Components Change this to enable or disable event logging for error/progress codes during boot. Enabled / Disabled Erase SEL Choose options for erasing SEL. No / Yes, on next reset / Yes, on every reset When SEL is Full Choose options for reactions to a full SEL.
  • Page 229 5.6.2 BMC Network Configuration http://www.tyan.com...
  • Page 230 Configure IPv4 support Management Port 1 Configuration Address Source Select the configure LAN channel parameters statically or dynamically (by BIOS or BMC). Unspecified option will not modify any BMC network parameters during BIOS phase. Unspecified / Static / DynamicBmcDhcp / DynamicBmcNonDhcp Management Port 2 Enable/Disable BMC Share NIC Disabled / Enabled...
  • Page 231 5.6.3 BMC User Configuration Add User Press <Enter> to Add a User. Delete User Press<Enter> to Delete a User. Change User Settings Press<Enter> to Change User Settings. http://www.tyan.com...
  • Page 232 5.6.3.1 BMC User Configuration User Name Enter BMC User Name. User Password Enter New Password to change. Password at least 8 characters. User Access Enable/Disable the BMC User’s Access. Enabled / Disabled Channel No Enter BMC Channel Number. N/A / 1 / 8 User Privilege Limit Enter BMC User Privilege Limit for Selected Channel.
  • Page 233 5.6.3.2 Delete User Configuration User Name Enter BMC User Name. User Password Enter New Password to change. Password at least 8 characters. http://www.tyan.com...
  • Page 234 5.6.3.3 Change User Configuration Submenu User Name Enter BMC User Name. User Password Enter New Password to change. Password at least 8 characters. Change User Password Enter New Password to change. Password at least 8 characters. User Access Enable/Disable the BMC User’s Access. Enabled / Disabled Channel No Enter BMC Channel Number.
  • Page 235: Security

    Security Administrator Password Set Administrator Password. User Password Set User Password. Security Frozen Mode Enable or disable HDD security freeze lock. Disable to support secure erase function. Disabled / Enabled Secure Boot Customizable Secure Boot settings http://www.tyan.com...
  • Page 236 5.7.1 Secure Boot Configuration Secure Boot Secure Boot feature is Active if Secure Boot is Enabled. Platform Key (PK) is enrolled and the System is in User mode. The mode change requires platform reset. Enabled / Disabled Secure Boot Mode Secure Boot mode options: Standard or Custom.
  • Page 237 Key Management Enables expert users to modify Secure Boot Policy variables without full authentication http://www.tyan.com...
  • Page 238 5.7.2 Key Management Factory Keys Provision Install factory default Secure Boot Keys after the platform reset and while the System is in Setup Mode. Enabled / Disabled Restore Factory Keys Force System to User Mode. Install Factory Default Secure Boot key databases. Reset To Setup Mode Delete all Secure Boot Key database from NVRAM Enroll Efi Image...
  • Page 239 Platform Key (PK) Enroll Factory Defaults or load certificates from a file: Public Key Certificate in: EFI_SIGNATURE_LIST EFI_CERT_X509 (DER encoded) EFI_CERT_RSA2048 (bin) EFI_CERT_SHA256,384,512 Authenticated UEFI Variable EFI PE/COFF Image(SHA256) Key Source: Default, External, Mixed, Test Set New Key Exchange Keys Enroll Factory Defaults or load certificates from a file: Public Key Certificate in: EFI_SIGNATURE_LIST...
  • Page 240 Default, External, Mixed Authorized TimeStamps Enroll Factory Defaults or load certificates from a file: Public Key Certificate in: EFI_SIGNATURE_LIST EFI_CERT_X509 (DER encoded) EFI_CERT_RSA2048 (bin) EFI_CERT_SHAXXX Authenticated UEFI Variable EFI PE/COFF Image(SHA256) Key Source: Default, External, Mixed OsRecovery Signatures Enroll Factory Defaults or load certificates from a file: Public Key Certificate in: EFI_SIGNATURE_LIST EFI_CERT_X509 (DER encoded)
  • Page 241: Boot

    Boot Setup Prompt Timeout Number of seconds to wait for setup activation key. 65535 (0xFFFF) means indefinite waiting. Bootup NumLock State Select the keyboard NumLock state. Off / On Quiet Boot Enable or disable Quiet Boot option. Enabled / Disabled Wait for ‘ESC’...
  • Page 242 Boot Option Priorities Boot Option #1 Select the system boot order. Device Name / Disabled Delete Boot Option Remove an EFI boot option from the boot order. http://www.tyan.com...
  • Page 243 5.8.1 Add Boot Option Configuration Delete Boot Option Remove an EFI boot option from the boot order. Select one to delete / Device Name http://www.tyan.com...
  • Page 244: Save & Exit

    Save & Exit Save Changes and Exit Exit system setup after saving the changes. Discard Changes and Exit Exit system setup without saving any changes. Save Changes and Reset Reset the system after saving the changes. Discard Changes and Reset Reset system setup without saving any changes.
  • Page 245 Save as User Defaults Save the changes done so far as User Defaults. Restore User Defaults Restore the User Defaults to all the setup options. Boot Override Device Name http://www.tyan.com...
  • Page 246: Chapter 6: Diagnostics

    Chapter 6: Diagnostics NOTE: if you experience problems with setting up your system, always check the following things in the following order: Memory, Video, CPU By checking these items, you will most likely find out what the problem might have been when setting up your system.
  • Page 247: Amibios Post Code (Aptio)

    AMIBIOS Post Code (Aptio) The POST code checkpoints are the largest set of checkpoints during the BIOS pre-boot process. The following table describes the type of checkpoints that may occur during the POST portion of the BIOS: Checkpoint Ranges Status Code Range Description 0x01 –...
  • Page 248 SEC Error Codes 0x0C – 0x0D Reserved for future AMI SEC error codes 0x0E Microcode not found 0x0F Microcode not found SEC Phase None PEI Phase Status Code Description Progress Codes 0x10 PCI Core is started 0x11 Pre-memory CPU initialization is started 0x12 Pre-memory CPU initialization (CPU module specific) 0x13...
  • Page 249 Status Code Description 0x33 CPU post-memory initialization. Cache initialization CPU post-memory initialization. Application Processor(s) (AP) 0x34 initialization CPU post-memory initialization. Boot Strap Processor (BSP) 0x35 selection CPU post-memory initialization. System Management Mode (SMM) 0x36 initialization 0x37 Post-Memory North Bridge initialization is started. Post-Memory North Bridge initialization (North Bridge module 0x38 specific)
  • Page 250 Status Code Description 0xE2 Video repost 0xE3 OS S3 wake vector call 0xE4 – 0xE7 Reserved for future AMI progress codes S3 Resume Error Codes 0xE8 S3 Resume failed 0xE9 S3 Resume PPI not found 0xEA S3 Resume Boot Script error 0xEB S3 OS wake error 0xEC –...
  • Page 251 Status Code Description 0x60 DXE Core is started. 0x61 NVRAM initialization 0x62 Installation of the South Bridge Runtime Services 0x63 CPU DXE initialization is started. 0x64 CPU DXE initialization (CPU module specific) 0x65 CPU DXE initialization (CPU module specific) 0x66 CPU DXE initialization (CPU module specific) 0x67 CPU DXE initialization (CPU module specific)
  • Page 252 Status Code Description 0x98 Console Input devices connect 0x99 Super IO initialization 0x9A USB initialization is started. 0x9B USB Reset 0x9C USB Detect 0x9D USB Enable 0x9E -0x9F Reserved for future AMI codes 0xA0 IDE initialization is started 0xA1 IDE Reset 0xA2 IDE Detect 0xA3...
  • Page 253 Status Code Description 0xD2 South Bridge initialization error 0xD3 Some of the Architectural Protocols are not available 0xD4 PCI resource allocation error. Out of Resources 0xD5 No Space for Legacy Option ROM 0xD6 No Console Output Devices are found. 0xD7 No Console Input Devices are found.
  • Page 254: Appendix I: How To Recover Uefi Bios

    Appendix I: How to recover UEFI BIOS Important Notes: The emergency UEFI BIOS Recovery process is only used to rescue a system with a failed or corrupted BIOS image that fails to boot to an OS. It is not intended to be used as a general purpose BIOS flashing procedure and should not be used as such.
  • Page 255 The system will boot to BIOS setup. A new menu item will appear at the far right of the screen. Scroll to the 'Recovery' tab, move the curser to “Proceed with flash update” and press the "Enter" key on the keyboard to start the BIOS recovery process.
  • Page 256: Appendix Ii: Cable Connection Tables

    Appendix II: Cable Connection Tables 1. System Fan Connector System Fan to BP System Fan M1299G68A-BPE-12 Connect to Fan1 → FAN1 Fan2 → FAN2 Fan3 → FAN3 Fan4 → FAN4 Fan5 → FAN5 Fan6 → FAN6 2. FP Control Cable Front Panel Board (FPB) to MB S8056GM2NE-2T-B / M1724G68-FPB...
  • Page 257: Power Cable

    5. Power Cable Power Board (PDB) to MB M1635T70E-D-PD S8056GM2NE-2T-B / Connect to S8056GME-B 2x12P PWR PWR1 → (2)2x4P PWR → → PSMI PSMI PSMI_HD1 Power Board (PDB) to BP M1635T70E-D-PD Connect to M1299G68A-BPE-12 2x8P to → PWR10 (2)2x4P PWR DOM_5V-PW1 →...
  • Page 258 7. NVME SIGNAL Cable BP to MB S8056GM2NE-2T-B / M1299G68A-BPE-12 Connect to S8056GME-B → NVME SIGNAL HDR1 HDR_5 http://www.tyan.com...
  • Page 259: Appendix Iii: Fan And Temp Sensors

    Appendix III: Fan and Temp Sensors This section aims to help readers identify the locations of some specific FAN and Temp Sensors on the motherboard. A table of BIOS Temp sensor name explanation is also included for readers’ reference. Figure 1: Sensor Location NOTE: The red spot indicates the sensor.
  • Page 260 BIOS Temp Sensor Name Explanation: http://www.tyan.com...
  • Page 261 http://www.tyan.com...
  • Page 262 BIOS Temp Sensor Name Explanation P0_Temp CPU0 Temperature P0_MOSFET1_Temp Temperature of P0 MOSFET1 P0_MOSFET2_Temp Temperature of P0 MOSFET2 P0_MOSFET3_Temp Temperature of P0 MOSFET3 SYS_Air_Inlet Temperature of the System Air Inlet Area SYS_Air_Outlet Temperature of the System Air Outlet Area MB_Air_Inet Temperature of the M/B Air Inlet Area OCP_Air_Inlet Temperature of the OCP_Air_Inlet Area...
  • Page 263 P0_CHG_DIM1 Temperature of CPU0 DIMM Channel G1 P0_CHH_DIM1 Temperature of CPU0 DIMM Channel H1 P0_ CHI_DIM1 Temperature of CPU0 DIMM Channel I1 P0_ CHJ_DIM1 Temperature of CPU0 DIMM Channel J1 P0_ CHK_DIM1 Temperature of CPU0 DIMM Channel K1 P0_ CHL_DIM1 Temperature of CPU0 DIMM Channel L1 U.2_NVME_SSD_0 Temperature of NVME_SSD_0...
  • Page 264: Appendix Iv: Fru Parts Table

    Appendix IV: FRU Parts Table GC68C-B8056 FRU Parts Item Model Number Part Number Picture Description Power PSU,860 W, Compuware, FRU-PS-0470 471100000601 Supply CDR-8611-4M3,(1.0) Passive,SBU,AMD 4th EPYC,H≤1U, FRU-TH-0700 343B02400002 Heatsink 165.2x216.81x28.5, PC-08309-01-GP2 TF-FAN ASSY;SBU,FAN,12V, FRU-TS-9270 422T60300001 40*40*28mm,4 PIN (HEADER2*4),WIRE module L=180MM,GC68-B7126 TF-FAN;SBU,FAN,12V, 40*40*56mm,8...
  • Page 265: Appendix V: Technical Support

    Appendix V: Technical Support If a problem arises with your system, you should first turn to your dealer for direct support. Your system has most likely been configured or designed by them and they should have the best idea of what hardware and software your system contains. Hence, they should be of the most assistance for you.
  • Page 266 (RMA) number. The RMA number should be prominently displayed on the outside of the shipping carton and the package should be mailed prepaid. TYAN will pay to have the board shipped back to you. ® TYAN GC68C-B8056 Service Engineer’s Manual V1.0b Document No.: D2600-100 http://www.tyan.com...

Table of Contents