Filtertechnik SFC-SEN-110-FTB-6-10 User Manual

Sentry light duty filter cart

Advertisement

Quick Links

Filtertechnik
1 Central Park, Lenton Lane, Nottingham, NG7 2NR
Tel:
+44 (0)115 9003 600
Email:
sales@filtertechnik.co.uk
Sentry Light Duty Filter Cart
User Manual
© Copyright 2015 Filtertechnik
Fax:
+44 (0)115 986 8875
Web:
www.filtertechnik.co.uk
October 2015
V1.01
Registered in England No: 03969985 VAT No: 760 821 731

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SFC-SEN-110-FTB-6-10 and is the answer not in the manual?

Questions and answers

Summary of Contents for Filtertechnik SFC-SEN-110-FTB-6-10

  • Page 1 Sentry Light Duty Filter Cart User Manual October 2015 V1.01 © Copyright 2015 Filtertechnik Filtertechnik 1 Central Park, Lenton Lane, Nottingham, NG7 2NR Tel: +44 (0)115 9003 600 Fax: +44 (0)115 986 8875 Email: sales@filtertechnik.co.uk Web: www.filtertechnik.co.uk Registered in England No: 03969985 VAT No: 760 821 731...
  • Page 3: Table Of Contents

    Suction Strainer ............................. 12 Troubleshooting ............................ 13 Spare Parts List ............................14 Warranty Statement ..........................14 EC Declaration of Conformity ........................ 15 Filtertechnik 1 Central Park, Lenton Lane, Nottingham, NG7 2NR Fax: +44 (0)115 986 8875 Tel: +44 (0)115 9003 600 Email: sales@filtertechnik.co.uk...
  • Page 4: Specifications

    Specifications Detail Specification SFC-SEN-110-FTB-6-10 SFC-SEN-240-FTB-6-10 Dimensions (w)420 mm x (d)450 mm x (h)1000 mm Weight 28.5 kg Frame Mild Steel Finish Powder Coated RAL 5004 (Black Blue) Satin Voltage 110 VAC (+10% to -6%) 240 VAC (+10% to -6%) Frequency...
  • Page 5: Typical Applications

    • Ensure a spill kit is available in case of any accidental spills. • Used filters must be disposed of in accordance with local environmental requirements. Filtertechnik 1 Central Park, Lenton Lane, Nottingham, NG7 2NR Fax: +44 (0)115 986 8875...
  • Page 6: Basic Description

    Fire / Explosion Water Oxidation Corrosive chemicals Oxidation / Injury to persons Solvents Fire / Explosion / Damage to gaskets Filtertechnik 1 Central Park, Lenton Lane, Nottingham, NG7 2NR Fax: +44 (0)115 986 8875 Tel: +44 (0)115 9003 600 Email: sales@filtertechnik.co.uk...
  • Page 7: Achieving Iso Cleanliness Codes

    Achieving ISO Cleanliness Codes Filtertechnik has a wide range of elements available to effectively achieve the required cleanliness level for the intended system. Maintaining the fluid at the required cleanliness level is a cost effective way of extending the service life of system components. The tables below can be used to...
  • Page 8 16,200 2,880 23/21/18 1,024,000 182,400 32,400 5,760 1,020 Table 4 – ISO 4406 vs NAS 1638 Contamination Filtertechnik 1 Central Park, Lenton Lane, Nottingham, NG7 2NR Fax: +44 (0)115 986 8875 Tel: +44 (0)115 9003 600 Email: sales@filtertechnik.co.uk Web: www.filtertechnik.co.uk...
  • Page 9: Component Identification

    8.) Pump on/off switch 4.) Outlet port (3/4” BSP) 9.) Adjustable relief valve 5.) Filter housing 10.) Inlet port (3/4” BSP) Filtertechnik 1 Central Park, Lenton Lane, Nottingham, NG7 2NR Fax: +44 (0)115 986 8875 Tel: +44 (0)115 9003 600 Email: sales@filtertechnik.co.uk...
  • Page 10: Starting & Stopping

    To start the unit ensure it is plugged in to the correct power supply and turn on via the switch located on the pumps electrical box. Filtertechnik 1 Central Park, Lenton Lane, Nottingham, NG7 2NR Fax:...
  • Page 11: Filtration

    When fitting the replacement filter element and bowl make sure all parts are correctly seated. The bowl should be torque tightened to 54 N.m (40 lb.ft). Filtertechnik 1 Central Park, Lenton Lane, Nottingham, NG7 2NR Fax: +44 (0)115 986 8875...
  • Page 12: Pump & Motor

    Max. Back Pressure Condition Max. Flow Rate Condition Q (ltrs/min) P (bar) Q (ltrs/min) P (bar) Q (ltrs/min) P (bar) Filtertechnik 1 Central Park, Lenton Lane, Nottingham, NG7 2NR Fax: +44 (0)115 986 8875 Tel: +44 (0)115 9003 600 Email: sales@filtertechnik.co.uk Web: www.filtertechnik.co.uk...
  • Page 13: Maximum Pressure Decrease

    Should it be necessary to decrease the maximum pressure, unscrew the adjusting screw until you reach the desired value. The flow rate curve will be modified as follows: Filtertechnik 1 Central Park, Lenton Lane, Nottingham, NG7 2NR Fax:...
  • Page 14: Hoses & Lances

    The suction strainer will periodically need cleaning by unscrewing the cap, removing the mesh strainer and cleaning this out with a fluid suited for the units intended purpose e.g. hydraulic oil. Filtertechnik 1 Central Park, Lenton Lane, Nottingham, NG7 2NR...
  • Page 15: Troubleshooting

    Brittle hoses would require replacement Oil spills under unit Defective shaft seal Replace seals where necessary Hose leaks Tighten all joints Filtertechnik 1 Central Park, Lenton Lane, Nottingham, NG7 2NR Fax: +44 (0)115 986 8875 Tel: +44 (0)115 9003 600 Email: sales@filtertechnik.co.uk...
  • Page 16: Spare Parts List

    Limited Express Warranties, and no others: For a period of one (1) year from and after the date of delivery of a new Filtertechnik product, Filtertechnik warrants and guarantees only to the original purchaser/user that such a product shall be free from defects of materials and workmanship in the manufacturing process.
  • Page 17: Ec Declaration Of Conformity

    EC Declaration of Conformity SENTRY FILTER CART Filtertechnik 1 Central Park, Lenton Lane, Nottingham, NG7 2NR Fax: +44 (0)115 986 8875 Tel: +44 (0)115 9003 600 Email: sales@filtertechnik.co.uk Web: www.filtertechnik.co.uk Registered in England No: 03969985 VAT No: 760 821 731...