Summary of Contents for HESA PREMIER 412
Page 1
Centrali Premier International PREMIER 412 (cod. TXP412) PREMIER 412M (cod. TXP412M) PREMIER 816 (cod. TXP816) PREMIER 816M (cod. TXP816M) PREMIER 816P (cod. TXP816P) PREMIER 816PM (cod. TXP816PM) PREMIER 832 (cod. TXP832) PREMIER 832M (cod. TXP832M) Manuale Installazione www.hesa.com • e-mail: hesa@hesa.com...
Contents Premier 412/816/832 Installation Manual Contents Service Faults ................21 System Overview ........5 Communicator ................21 Operation ..................22 System Architecture ............5 Control Panels ..............5 Programming the Control Panel ....23 ...
Premier 412/816/832 Installation Manual Contents Fast Format Open/Close Channels ......56 Anti-code Reset .............. 77 Cancel Call Waiting Sequence ......... 56 Toggle Chime On and Off ..........77 Programming Check List ............57 ...
Page 4
Contents Premier 412/816/832 Installation manual System Overview Installation Control Panel PCB Layout Installing Remote Keypads & Expanders Zone Connections Siren/Bell, Telephone and Panel Outputs Commissioning & Troubleshooting Programming Menus Programming Zones Programming Partitions Programming Global Options Programming Remote Keypads Programming Remote Expanders...
Centre Control Panels Remote Keypads The Premier 412, 816 and Premier 832 are highly The control panels will accept up to a maximum of 6 remote sophisticated security control panels with Integrated Multi- keypads. All remote keypads require a 4-wire connection to protocol Digital Communicator/Modem.
PC-Com Module off, changing to bright whenever a keypad is used and during the entry mode This module plugs on to the Premier 412, 816 and Premier • Dedicated status lights for “Alarm”, “Service”, “Armed”, 832 control panel to provide an RS232 interface, which can “Ready”, “Fire”, “Bypass”, “Instant”...
Premier 412/816/832 Installation Manual Installation 2. Installation Installation Sequence Control Panel Before attempting to install the alarm system, read this Mounting section. Once you have an overall understanding of the Mount the control panel on a flat, plumb wall using at least installation sequence, carefully work through each step.
The Premier 816 and Premier 832 have 8 zone inputs, Connect to a 16.5V transformer. whereas the Premier 412 has only 4 zone inputs. There are Do NOT connect the mains supply to the AC several ways to wire a zone (see page 13). Each zone is fully input terminals.
Premier 412/816/832 Installation Manual Installation 11: Communication Ports 1 and 2 green receive (Rx) LED indicates that data is flowing into the Serial communication ports 1 and 2, these can be used for control panel. The green LED flashes faster as more devices third party devices or PC for local downloading.
Installation Premier 412/816/832 Installation Manual Overcoming Voltage Drop • When using a daisy chain (series) configuration the maximum distance will depend on the number of There are several ways to overcome voltage drop: devices connected on the chain. The more devices that •...
Premier 412/816/832 Installation Manual Installation Address DIL Switch Installing Remote Keypads Tamper Switch Piezo Sounder Keypad Layouts Data Bus Connections Programmable Zones 1 and 2 Speaker Output (Premier LCDL/LCDLP Only) Programmable Output Remote Keypad Connections The remote keypad is connected to the data bus terminals located at the bottom left hand side of the PCB.
Only one remote expander can be connected to the Premier 412 & 816 control panels (Address = 1). Remote Expander Layout Remote Expander Zones The Premier 8X Remote Expander has eight programmable zone inputs (see page 14 for wiring details).
Premier 412/816/832 Installation Manual Installation Zone Expander Outputs The table below shows the zone allocation when the module The Zone Expander module has two programmable outputs, is installed: which can be used to drive auxiliary devices such as relays, Panel...
Installation Premier 412/816/832 Installation Manual Normally Closed Zone Connections Use this wiring configuration when connecting normally closed detection devices to the zone. Ensure that the zone Each zone on the system is fully programmable to allow for is programmed for Normally Closed operation (see page maximum flexibility (see page 25 for Zone Programming 27).
Premier 412/816/832 Installation Manual Installation Single EOL - N/C & N/O (Burglary) Single EOL - N/O (Fire) Use this wiring configuration when connecting a mixture of Use this wiring configuration when connecting a 4-wire normally closed and normally open detection devices to the smoke detector to the zone.
Installation Premier 412/816/832 Installation Manual Single EOL - N/C Double EOL Use this wiring configuration when connecting just normally Use this wiring configuration when connecting detection closed detection devices to the zone. Ensure that the zone devices to a zone that requires alarm/tamper monitoring.
Premier 412/816/832 Installation Manual Installation The following table shows how each physical zone is Premier LCD/LCDL mapped when using the “Zone Doubled” configuration: Keypads Premier 412 Zone x Panel Zone Zone A Zone B Control Panel & Expanders Premier 816/832...
Installation Premier 412/816/832 Installation Manual Siren/Bell Operation 2-Wire Smoke Detector When configured as bell operation the output terminals provide up to 750mA of power for driving bells as shown: Compatible 2-wire smoke detectors such as the ESL429AT or System Sensor 2100TS can be connected as shown:...
Premier 412/816/832 Installation Manual Installation Panel Outputs 1 - 8 The control panel has eight programmable outputs, which can be used to drive auxiliary devices such as relays, LED’s, smoke detectors etc. The table below shows the electrical characteristics for each output:...
Commissioning & Troubleshooting Premier 412/816/832 Installation Manual 3. Commissioning & Troubleshooting Commissioning Troubleshooting Once ALL connections have been made to the control panel Power Faults and power is ready to be applied, you should read this section before continuing. No Power to Unit (mains only) •...
Premier 412/816/832 Installation Manual Commissioning & Troubleshooting • If the battery presence check is enabled the system will Keypad Does Not Generate Alarm Tones etc. • Each keypad can be configured so that the alarm, entry, check the battery every 30 seconds. If the system does exit, chime tones etc.
Commissioning & Troubleshooting Premier 412/816/832 Installation Manual Operation The System Will Not Allow Arming • Check that there are no outstanding Service Faults, see page 76. • Check that there are no outstanding alarms that require resetting, see page 75.
Premier 412/816/832 Installation Manual Programming the Control Panel 4. Programming the Control Panel Viewing Numeric Data (LED Keypads) Introduction When programming numeric data, the value of the data may be viewed by pressing the key. The keypad will flash All engineers should read this section carefully so as to...
Programming the Control Panel Premier 412/816/832 Installation Manual Program Menus Menu Function Page Menu Function Page Programming Zones Programming System Outputs All Zone Options Panel Outputs Zone Type Fast Format Channels Zone Wiring Expander 1 Outputs Zone Attributes 1 Expander 2 Outputs...
Premier 412/816/832 Installation Manual Programming the Control Panel Programming Zones Enter Engineers code ???? Then press then Programming Menu Led Key Enter Code > Slow Flash Zones Fast Flash Armed Alarm Service Ready All Zone Options All Zone Options Zone Types Enter Zone Type Enter Zone No.??
Programming the Control Panel Premier 412/816/832 Installation Manual From Previous Page Zone Attributes 3 Zone 00 Att. 3 Zone 01 Att. 3 Zone Attributes 3 Enter Zone No.?? > 1******* < Change to Delay 1 on Stay Arm Enter Zone Number...
Premier 412/816/832 Installation Manual Programming the Control Panel Fire Momentary Key Switch This zone type is normally used for monitoring smoke This zone type can be used to arm/disarm and reset one or detectors. The zone will cause a unique alarm with more partitions.
Programming the Control Panel Premier 412/816/832 Installation Manual Enable Bell Enable Cross Zoning On: The bell output will trigger when the zone causes an On: When two or more zones are programmed with this alarm. attribute, the system will start the Cross Zone Delay Off: The bell output will not trigger.
Premier 412/816/832 Installation Manual Programming the Control Panel Off: Force armed zones remain bypassed until the partition be assigned to Partitions 1 - 4. If a zone is assigned to more is disarmed. than one partition it will only be armed when all partitions they are assigned to are armed.
Programming the Control Panel Premier 412/816/832 Installation Manual Programming Partitions Enter Engineers code ???? Then press then Programming Menu Led Key Enter Code > Slow Flash Zones Fast Flash Armed Alarm Service Ready Exit Delay Exit Delay Exit Delay Note Partition No.
Premier 412/816/832 Installation Manual Programming the Control Panel From Previous Page Bell Duration Bell Duration Bell Duration Note Partition No. ? Enter Value: 015 If the system only has 1 partition, Enter Partition No. the option to enter the Partition No...
Programming the Control Panel Premier 412/816/832 Installation Manual Enable Remote Arming When the control timer switches on, the panel will On: The selected partition can be armed remotely via start a 2 minute exit timer. During the first 90 seconds download software.
Premier 412/816/832 Installation Manual Programming the Control Panel Programming Global Options Enter Engineers code ???? Then press then Programming Menu Led Key Enter Code > Slow Flash Zones Fast Flash Alarm Armed Service Ready System Timers System Timers Line Fault Delay System Timers Enter Timer >...
Page 34
Programming the Control Panel Premier 412/816/832 Installation Manual From Previous Page System Options 1 System Options 1 System Options 1 > ****56*8 < System Clock = Crystal Use keys Battery Connection Supervision select/deselect Options. Zones Battery Dynamically Load Tested Then press...
Premier 412/816/832 Installation Manual Programming the Control Panel System Timers Verified 2-Wire Smoke Delay These timers control the system timing and delay functions. When the timer is set to zero 2-wire smoke detectors are The function of each timer is described as follows: unverified, i.e., as soon as a detector activates, the panel will...
Programming the Control Panel Premier 412/816/832 Installation Manual Language Selection Battery Dynamically Load Tested This option selects the operating language of the system. On: The standby battery is tested when any partition is Use the scroll keys to display the available languages, then disarmed or every 12 hours from the last battery test.
Premier 412/816/832 Installation Manual Programming the Control Panel partition 15 seconds after the last key press or 1 Inhibit Keyswitch Operation upon EOL Tamper minute after the last entry of a User code. On: Tampering of a keyswitch zone will inhibit the keyswitch operation.
Programming the Control Panel Premier 412/816/832 Installation Manual they have a special auto re-arm feature. When either Auxiliary Fuse Supervised for Faults input type is used to disarm one or more partitions, On: The Auxiliary 12V Power fuse is supervised, and if the fuse is blown, the system will generate an “Aux Fuse...
Premier 412/816/832 Installation Manual Programming the Control Panel Off: If a non “delay” or “follower” zone is activated during Enable Confirmation After Entry Time-Out exit mode the panel will generate a fault condition. On: If option 5 (above) is enabled the Confirmation output...
Programming the Control Panel Premier 412/816/832 Installation Manual Programming Remote Keypads Enter Engineers code ???? Then press then Programming Menu Led Key Enter Code > Slow Flash Zones Fast Flash Armed Alarm Service Ready Keypad Options 1 Keypad Options 1...
Premier 412/816/832 Installation Manual Programming the Control Panel Keypad Options 1 Keypad Activation of Medical Alarm The operation of Keypad Options 1 is described as follows: On: The selected keypad will generate an emergency Medical alarm if keys are pressed at the Partition 1 Operation same time.
Programming the Control Panel Premier 412/816/832 Installation Manual Error Tones from Keypad Zone Shift by 8 On: The internal sounder for the selected keypad will On: The remote keypad zone status lights indicate from produce Error tones. Zone 9 onwards i.e., Zone 1 on the remote keypad Off: Error tones will not be produced.
Premier 412/816/832 Installation Manual Programming the Control Panel Programming Remote Expanders Enter Engineers code ???? Then press then Programming Menu Led Key Enter Code > Slow Flash Zones Armed Fast Flash Alarm Service Ready Expander Partitions Expander Areas Expander Areas Expander Partitions Enter Exp No.
Programming the Control Panel Premier 412/816/832 Installation Manual Expander Partitions When the expander is assigned to one or more partitions the speaker output on the expander will generate tones only for the partition(s) it’s assigned to. E.g. if the expander is assigned to partition 3, the speaker will only be enabled when partition 3 is in alarm, entry, exit etc.
Premier 412/816/832 Installation Manual Programming the Control Panel Programming System Outputs Enter Engineers code ???? Then press then Programming Menu Led Key Enter Code > Slow Flash Zones Fast Flash Alarm Armed Service Ready Panel Outputs Panel Outputs Panel Outputs...
Page 46
Programming the Control Panel Premier 412/816/832 Installation Manual From Previous Page Expander 3 Outputs Exp. 3 Outputs Enter Output No? Follow procedure for Enter Output Number Only available on the Premier 832 Panel Outputs (Menu 60) Zones Alarm Armed Service...
Premier 412/816/832 Installation Manual Programming the Control Panel Timed Arming Countdown Panel Outputs This output type activates when the system initiates a timed This menu option allows you to program the eight control arm. panel outputs. Zone Soak Test Active...
Page 48
Programming the Control Panel Premier 412/816/832 Installation Manual Service Required/Test Fail 24Hr - Water Alarm This output type activates when a Service Required fault This output type activates when a 24hr Water alarm is exists or the system has failed zone soak test.
Premier 412/816/832 Installation Manual Programming the Control Panel Stay Armed Away Armed/Exit This output type activates when the selected Partition is stay This output type activates when the partition is in exit mode armed. (Away arming) and when the partition is “Away Armed”.
Programming the Control Panel Premier 412/816/832 Installation Manual Programming the Communicator Note Enter Engineers code ???? Only Engineer codes that have the “Allow NVM Locking/Communicator Programming” option are Then press then allowed to access menus 70 - 79. Programming Menu Led Key Enter Code >...
Page 51
Premier 412/816/832 Installation Manual Programming the Control Panel From Previous Page Protocol Type Protocol Types Disabled Protocol Pulse Format Contact ID Enter Protocol type Express Format LCD: to scroll type Fast Format/Speech Module Zones then press Contact ID Alarm Armed...
Programming the Control Panel Premier 412/816/832 Installation Manual From Previous Page Fast Format Restore Channels Restore Channels Fast Format Restore Channels > 12345678 < 1 Report Restore on Channel 1 Use keys Report Restore on Channel 2 select/deselect Channels. Zones...
Premier 412/816/832 Installation Manual Programming the Control Panel Telephone Numbers Contact ID Alarm Receiving Centre 1 has a primary and secondary The panel will communicate with Alarm Receiving Centre 1 telephone number. The primary number is the number that using Contact ID. The defaults Contact ID codes are shown is dialled first and if programmed the secondary telephone in the accompanying “Installation Records and Defaults”...
Programming the Control Panel Premier 412/816/832 Installation Manual Pulse Format Options The maximum number of repeat dialling attempts is If ARC 1 protocol is programmed for “Pulse Format”, the limited to 9. The system will only allow you to enter pulse format protocol can be changed using this menu values between 0 and 9.
Premier 412/816/832 Installation Manual Programming the Control Panel Fast Format Reporting Channels • If the account number is not programmed for This option defines which channels are reported to Alarm partitions 2, 3 and 4, the global (partition 1) account number is used.
Programming the Control Panel Premier 412/816/832 Installation Manual ARC 2 Communicator Options Report Open/Close on Channel 4 This option allows the on-board communicator to be On: Open/Close reported on channel 4. Off: Open/Close not reported on channel 4. configured for Alarm Receiving Centre 2. The same options...
Premier 412/816/832 Installation Manual Programming the Control Panel Programming Check List The table below provides a checklist of what options require programming for each of the protocols supported: Protocol Notes 1. Program to type 1. Pulse Format 2. Use table on page 54.
Programming the Control Panel Premier 412/816/832 Installation Manual Programming Download Options Note Ente r Engine e rs code Only Engine e r code s tha t ha ve the “ Allow N VM Lockin g/C om m u n ica tor Progra m m in g” option a re...
Premier 412/816/832 Installation Manual Programming the Control Panel From Previous Page Com 1 Device Type D evic e Types PC -C om /U SB-C om Ra dioPlus Ente r D e vice type Inovon ics Ra dio LCD : U se...
Programming the Control Panel Premier 412/816/832 Installation Manual Com1 Device Type Download when Part Armed If option 4 above is enabled, then downloading is restricted This option allows you to specify which module is connected as follows: to communication port Com1.The control panel will accept...
Premier 412/816/832 Installation Manual Programming the Control Panel Programming Reporting Codes Note Enter Engineers code ???? Only Engineer codes that have the “Allow NVM Locking/Communicator Programming” option are Then press then allowed to access menus 70 - 79. Programming Menu Led Key Enter Code >...
Programming the Control Panel Premier 412/816/832 Installation Manual Zone Alarm/Restore Codes Alarm Restore Event Type This menu option allows you to change the alarm/restore Event No Event No reporting event codes for each zone. These codes are used Code Tamper Alarm...
Premier 412/816/832 Installation Manual Programming the Control Panel Programming Users Enter Engineers code ???? Then press then Programming Menu Led Key Enter Code > Slow Flash Zones Fast Flash Alarm Armed Service Ready Program User Program User 00 Program User 03 Enter User No.??
Programming the Control Panel Premier 412/816/832 Installation Manual From User Text Previous Page Engineer Engineer Text Editing Keys to select User. User 00 Text ^ser 00 Text n to edit text. . , ? ! 1 @ ” - &...
Off: The user cannot bypass zones. the engineer) that are available is as follows: Allow Disarming • Premier 412 - 32 Users On: The user can disarm the partitions they have been • Premier 816 - 32 Users given access to.
Programming the Control Panel Premier 412/816/832 Installation Manual Off: The Access code cannot access the user program Activate Door Strike Output menus. On: When a user Access code is entered, the output type “Door Strike” (see page 49) is activated for 2 seconds.
Premier 412/816/832 Installation Manual Programming the Control Panel System Tests & Utilities Enter Engineers code ???? Then press then Programming Menu Led Key Enter Code > Slow Flash Zones Fast Flash Alarm Armed Service Ready Walk Test Walk Test Zone 01 Active...
Programming the Control Panel Premier 412/816/832 Installation Manual From Previous Page Banner Text (LCD Only) Premier 816 Premier 816 Text Editing Keys Press to edit text. Banner Text ^anner Text . , ? ! 1 @ ” - & a b c 2 A B C d e f 3 D E F Use keys to enter/edit text.
Premier 412/816/832 Installation Manual Programming the Control Panel 5. Program the zone type and attributes as required. Note: Using RadioPlus The Zone Wiring must be programmed as “Double EOL”, if a tamper response is required from the Introduction detector. This section describes how to install and program the 6.
Programming the Control Panel Premier 412/816/832 Installation Manual Removing Remote Fobs If a remote fob is no longer required it must be unassigned from the system. To remove a remote fob from a user, proceed as follows: 1. Select engineer’s mode by entering the engineer code...
Premier 412/816/832 Installation Manual Operating the Alarm System 5. Operating the Alarm System To Away arm the alarm system proceed as follows: Introduction Enter Access code ???? Before attempting to operate the alarm system ensure you have familiarised yourself with all the arming and disarming...
Operating the Alarm System Premier 412/816/832 Installation Manual Cancelling the Arming Process Disarming after an Alarm To cancel the arming process during the exit delay: To disarm the alarm system after an alarm, proceed as follows: Enter Access code ????
Premier 412/816/832 Installation Manual Operating the Alarm System Stay Arming Partitions To change from Instant Stay to Delayed Stay, proceed as follows: This option allows you to Stay arm one or more partitions. Ensure that the system is Instant Stay armed.
Operating the Alarm System Premier 412/816/832 Installation Manual Changing to another Partition To manually bypass zones, proceed as follows: Normally the remote keypad that you use will be assigned to Enter Access code ???? a particular partition and therefore the zone and status lights will indicate information relevant to the assigned partition.
Premier 412/816/832 Installation Manual Operating the Alarm System To Bypass a group of zones, proceed as follows: To Quick Bypass a group of zones and Stay arm, proceed as follows: Enter Access code ???? Enter bypass group 1 4 YES to Arm?
Operating the Alarm System Premier 412/816/832 Installation Manual Service Faults Service Faults Displayed on LED Keypads Light Fault Condition The response to a Service Fault condition is programmed by the installer but is normally limited to the keypad buzzer. To AC Fail silence the Service Fault alarm, enter your Access code.
Premier 412/816/832 Installation Manual Operating the Alarm System Enter Access code ???? Anti-code Reset YES to Arm? Zones Alarm Armed MENU for Options This feature is normally used in the UK where users are not Service Ready permitted to reset the panel following a communicated Enter N5 alarm.
Specifications Premier 412/816/832 Installation Manual 6. Specifications Onboard Communicator Control Panel Protocols: Pulse Format, Express Format, Fast Format, Contact ID, SIA Power Supply Level 2/3, Pager and Mobile Phone Maximum Current Rating Dialling Formats: Pulse or DTMF REN: 16.5V , 25VA transformer:...
Premier 412 Speaker Output: Minimum load 4Ω Premier 412 with ISDN Communicator Outputs Premier 412 with 700mA Battery Charger O/P 1 & OP 2: 100mA switched to 0V Premier 412 with 900mA Battery Charger Environmental Premier 412 with DPT-TE-001 Communicator...
For Alarms and Tamper the inhibit function is controlled by the Swinger shutdown counter which is programmable and is defaulted European Standards to 3. The Premier 412/816/832 conforms to the European Union See page 27 & 34 for details. (EU) Low Voltage Directive (LVD) 73/23/EEC (amended by Minimum Logical Keys...
Premier 412/816/832 Installation Manual Quick Reference Guide 7. Quick Reference Guide Menu Function Page Menu Function Page Programming Zones Programming Partitions All Zone Options Partition Exit Time Zone Type Partition Entry Delay 1 Time Null 24-Hour Tamper Partition Entry Delay 2 Time...
Page 82
Quick Reference Guide Premier 412/816/832 Installation Manual Menu Function Page Menu Function Page System Options 2 Programming Remote Keypads Tamper Alarms Cause a Trouble While Disarmed Keypad Options 1 Tamper Alarms Cause a Trouble While Stay Armed Partition 1 Operation...
Page 83
Premier 412/816/832 Installation Manual Quick Reference Guide Menu Function Page Menu Function Page Programming System Outputs Programming The Communicator Panel Outputs Communicator Options Fast Format Channels Enable On-Board Communicator Enable DTMF Dialling Expander 1 Outputs Switch to Pulse Dialling after 3...
Page 84
Quick Reference Guide Premier 412/816/832 Installation Manual Menu Function Page Menu Function Page User Options 2 ARC 2 Communicator Menu Enable One Time Use Access Code Fast Format Restore Channels Time Lock Code with Control Timer 1 Report Restore on Channel 1...
Page 85
Premier 412/816/832 Installation Manual Quick Reference Guide Service Faults Displayed on LED Keypads User Functions Light Fault Condition Enter User Code followed by AC Fail Reset Alarm/Troubles Telephone Line Fault View Last Alarm 2-Wire Smoke Alarm View/Acknowledge Service Faults Box Tamper & Auxiliary Input:...
Quick Reference Guide Declaration of Conformity This declaration is valid for the following product: Device Type: Intruder Alarm Control Panel Product Name: Premier 412, Premier 816, Premier 816 plus, Premier 832 Control Panels Security Standards CLC/TS 50131-3:2003 Control and indicating equipment EN50131-1:2006...