Download Print this page

Vision ZL7435IN-8 Installation & Operation Manual

In-wall switch, 2 relays (screw terminal)

Advertisement

Quick Links

Federal Communications Commission Statement
This equipment has follows with the limits for a Class B digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in accordance with the
instruction, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try and
correct the interferene by one of the following measures:
-Reorient or relocate the receiving antenna,
-Increase the separation between the equipment and receiver,
-Connect the equipment into and outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undersired
operation.
FCC Caution: Any changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to operate this equipment.
Limited Warranty
Vision Guarantees that every In-Wall Switch module is free from physical defects in
material and workmanship under normal use for one year from the date of purchase. If
the product proves defective during this one-year warranty period, Vision will replace it
free of charge. Vision does not issue any refunds. This warranty is extended to the
original end user purchase only and is not transferable. This warranty does not apply to
: (1) damage to units caused by accident, dropping or abuse in handling, or any
negligent use; (2) units which have been subject to unauthorized repair, taken apart, or
otherwise modified; (3) units not used in accordance with instruction; (4) damages
exceeding the cost of the product; (5) transit damage, initial installation costs, removal
cost, or reinstallation cost.
For information on addional devices, plesae visit us at www.visionsecurity.com.tw
Introduction
Thanks for choosing the Vision's In-Wall Switch module of the home automation device.
This module is a Z-Wave® enabled device (interoperable, two-way RF mesh networking
technology) and is fully compatible with any Z-Wave® enabled network and it's security
framework. Every mains powered Z-Wave enabled device acts as a signal repeater and
multiple devices result in more possible transmission routes which helps eliminate "RF
dead-spots".
Z-Wave® enabled devices displaying the Z-Wave® logo can also be used with it
regardless of the manufacturer, and ours can also be used in other manufacturer's
Z-Wave® enabled networks. With special design, this module can fit into most of
electronic box in the market. This module will send On/Off signal to the appliance that
attached to this module by receiving Z-Wave® signal from controller. It also can control
two appliances independently. When the device is secure included into Z-Wave
network, above communication will be encrypted.
Product Description and Specification
Specification:
Protocol: Z-Wave®
Frequency Range:
865.22MHz (ZL7435IN-8)
868.10MHz (ZL7435MY-8)
868.42MHz (ZL7435EU-8)
869.00MHz (ZL7435RU-8)
908.42MHz (ZL7435US-8)
912.00MHz (ZL7435USLR-8)
916.00MHz (ZL7435IL-8)
919~923MHz (ZL7435KR-8)
919.80MHz (ZL7435HK-8)
922~926MHz (ZL7435JP-8)
921.42MHz (ZL7435BR-8)
Operating Range: Up to 100 feet line of sight
Operating Temp.: -15°C~ 60°C (5°F~140°F)
Operating Voltage: 90VAC~240VAC
Resistive Load:
550W for 110VAC
1100W for 220VAC
ZL 7435-8
V0
1130815
Package Content:
1pc ZL 7435-8 In-Wall Switch,
2 Relays (Screw Terminal)
1pc Installation & Operation
Manual
Configuration –
Supervision Report delayed reception time
Size
500 ~ 10000 (unsigned decimal) Unit: ms
Parameter 9
2
(Parameter 9)
Configuration –
Wake Up Test Mode
Size
0x00 (Off) 0xFF (Device always Wake-Up)
Parameter 224
1
(Parameter 224)
Installation & Operation Manual
In-Wall Switch, 2 Relays
(Screw Terminal)
Operation
Turn on or turn off two individual appliances that attached to ZL7435 by Z-Wave®
Interface Controller
Installation
Notice: If you are installing the entire Z-Wave® system for the first time, please
refer to the installation guide of Z-Wave® Interface Controller before installing
ZL7435 In-Wall Switch Module.
Following the wiring diagram to install ZL7435.
Note: Place antenna toward the surface and away from metal to get better signal.
*Front Side:
VALUE
Default
To set up the Supervision Report delayed reception time
VALUE
Default
0x00 (Off)
To wake up the Test Mode for testing the command class and signal
purpose only. Please do not try it out of these two purposes.
ZL7435IN-8
ZL7435MY-8
ZL7435EU-8
ZL7435RU-8
ZL7435US-8
ZL7435USLR-8
ZL7435IL-8
ZL7435KR-8
ZL7435HK-8
ZL7435JP-8
ZL7435BR-8
www.visionsecurity.com.tw
*Back Side:
500 ms.

Advertisement

loading
Need help?

Need help?

Do you have a question about the ZL7435IN-8 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Vision ZL7435IN-8

  • Page 1 Vision will replace it ZL7435JP-8 free of charge. Vision does not issue any refunds. This warranty is extended to the ZL7435BR-8 original end user purchase only and is not transferable. This warranty does not apply to : (1) damage to units caused by accident, dropping or abuse in handling, or any negligent use;...
  • Page 2 For “SW1/SW2’s Control”: Press SW1/SW2 to control 1st/2nd Relay’s On & LED Status after Power On: - Excluded:: red LED blink 5 times Off. - Included: : red LED blink once & send Indicator Report. Byte Value For “Learning SW1/SW2 neon light mode”: Long-pressed the Learn SW Binary Switch Set(0xFF) Basic Set On button for 5~10 seconds and released, then:...

This manual is also suitable for:

Zl7435my-8Zl7435eu-8Zl7435ru-8Zl7435us-8Zl7435uslr-8Zl7435il-8 ... Show all