CETO UMR‐903 is a Universal Motion Remote with a motion 
sensor, programmable for unparalleled energy savings up to 
60% in the operation of any air‐conditioning system that 
incorporates a built‐in remote‐control receiver. CETO can 
detect human motion within a 25‐foot distance and control 
the operation of an air‐conditioner according to the presence 
of human motion and can be programmed to turn the air‐
conditioner completely off or have the setting temperature 
increased to a desired setting for incredible energy savings. 
 
It is capable of operating over 6,000 different brands and 
models of air‐conditioners. 
BRAND CODE Setting  
 
 Find the code from the brand code list. If there are too many 
codes for one brand, try the first. If it doesn't work, please try 
the second until it does work. For example: MITSUBISHI, first 
you try '0476', if it doesn't work, try '0477'. 
 Press the 'SELECT' button for 3 seconds and the brand code 
on the LCD will flash. Press 
code appears. Pressing the 'MODE' button allows each press 
to increase the code value in increments of a hundred. Then 
press the 'ENTER' button, the brand code will stop flashing. 
Setting is complete, and you can control your air conditioner.
AUTO‐SEARCH Code Setting 
If you don't know the brand of your air‐conditioner or can't find 
the required brand from the brand code list, please operate as per 
the following steps: 
 Press and hold the 'SELECT' button for 6 seconds, then release it 
(the code displayed on the LCD screen increases automatically). 
When the air‐conditioner receives the corresponding signal and 
produces a buzzer sound, press any button to confirm the setting 
quickly. 
 After turning on the air conditioner, try other function buttons. If 
they don't work, repeat above steps until they do. 
PIR Human Detection Setting 
The 'PIR' button is used for 'ECO' and 'DELAYED STOP' functions. 
ECO function is the default setting for COOLING, HEATING and DRY 
modes. The 'DELAYED STOP' function is disabled when CETO is in 
ECO mode. 
Every time the air conditioner is turned on or switched between 
different modes, the ECO function sign will be displayed. In ECO 
Mode, the air‐conditioner will automatically adjust temperature 
settings once there is no motion detected within the given time. 
In 'DELAYED STOP' mode, the unit will stop running after the set 
time and will not turn back on automatically when motion is 
detected. 
  DDWDW 
 
     CETO SMART OPERATION MANUAL 
or 
 until the required brand 
 
 
DELAYED STOP 
DELAYED STOP function is disabled when CETO is in ECO 
Mode. To cancel the ECO setting and switch to DELAYED STOP, 
press and hold the 'PIR' and 'ENTER' buttons for 3 seconds, 
then press the 'PIR' button to enter the DELAYED STOP 
setting. 
Pressing the 'PIR' button at any time will cancel the DELAYED 
STOP function. When CETO is turned OFF then back ON, it will 
switch back to ECO as the default setting. 
 
Default setting: Will turn off the A/C in half an hour 
without any motion detection. This time is adjustable.  
Setting method: Press 'TIMER' and 'SWING' buttons 
simultaneously to enter the time setting mode. Then press 
TEMP+ or TEMP‐ to adjust time, each press will increase or 
decrease the setting for 0.5 hours (range is 0.5 – 4 hours). 
Press 'ENTER' to finalize the setting. 
Air‐conditioning unit will not turn back on automatically 
when any motion is detected. 
ECO Function 
ECO function is the default setting for COOLING, HEATING 
and DRY modes, and is active each time the air conditioner is 
turned on or switched between different modes. 
 
To cancel the ECO setting, press and hold the 'PIR' and 
'ENTER' buttons for 3 seconds. 
ECO setting is invalid in the FAN ONLY (Ventilation) mode. 
Default setting: After 30/60 minutes, the temperature rises 
to 26/28C in cooling mode, and 20/16C in heating mode. 
Time and temperature are both adjustable. 
Setting method: Press 'TIMER' and 'MODE' simultaneously 
to enter the time setting. Then press TEMP+ or TEMP‐ to 
adjust time. Each press increases 5 minutes (range is 5 – 60 
minutes). Press 'ENTER' to finalize the setting.  
Press 'TIMER' and 'FAN' simultaneously to enter the 
temperature setting. Then press TEMP+ or TEMP‐ to adjust 
the temperature of the first ECO period set. Each press 
increases the temperature by 1C (range is 1 – 14C). Press 
'ENTER' and the second period of temperature can be set. 
Press 'ENTER' to confirm the settings. 
In ECO mode when any motion is detected, the air‐
conditioning unit will reset back to its original setting. 
 
`FFF 

Advertisement

loading
Need help?

Need help?

Do you have a question about the UMR-903 and is the answer not in the manual?

Questions and answers

Summary of Contents for Ceto UMR-903

  • Page 1      CETO SMART OPERATION MANUAL        CETO UMR‐903 is a Universal Motion Remote with a motion  sensor, programmable for unparalleled energy savings up to  60% in the operation of any air‐conditioning system that  incorporates a built‐in remote‐control receiver. CETO can  detect human motion within a 25‐foot distance and control  the operation of an air‐conditioner according to the presence  of human motion and can be programmed to turn the air‐ DELAYED STOP  conditioner completely off or have the setting temperature  increased to a desired setting for incredible energy savings.  DELAYED STOP function is disabled when CETO is in ECO    It is capable of operating over 6,000 different brands and  Mode. To cancel the ECO setting and switch to DELAYED STOP,  models of air‐conditioners.  press and hold the ‘PIR’ and ‘ENTER’ buttons for 3 seconds,  then press the ‘PIR’ button to enter the DELAYED STOP  setting.  BRAND CODE Setting   Pressing the ‘PIR’ button at any time will cancel the DELAYED     Find the code from the brand code list. If there are too many  STOP function. When CETO is turned OFF then back ON, it will  switch back to ECO as the default setting.  codes for one brand, try the first. If it doesn’t work, please try    the second until it does work. For example: MITSUBISHI, first   Default setting: Will turn off the A/C in half an hour  you try ‘0476’, if it doesn’t work, try ‘0477’.  without any motion detection. This time is adjustable.    Press the ‘SELECT’ button for 3 seconds and the brand code   Setting method: Press ‘TIMER’ and ‘SWING’ buttons ...
  • Page 2 CETO SMART OPERATION MANUAL    C / F Function  TIMER OFF Setting  You can set the timer off only after turning on your air‐  Default setting: F (range 61 – 86F or 16 – 30C)  conditioner.  adjustable in 1‐degree increments for either F or C.   Setting method: Press TEMP+ and TEMP‐   Press the ‘TIMER’ button, the clock signal ‘OFF’ will appear  simultaneously to convert C to F and vice versa.  and time‐flash on the LCD display.      Press   and   buttons to adjust the time you want the  NIGHT LIGHT Setting  air‐conditioner to turn off.        The displayed time will stop flashing after 10 seconds. The  To turn on the night light, press the ‘MODE’ and  LCD will display the current time and timer signal ‘OFF’.  ‘ENTER’ buttons simultaneously.  This indicates the timer OFF setting is finalized.  You will see   displayed on the LCD. This indicates     The time range you can set is 00 – 24 hours.  the night light function is on.  1) Press the ‘TIMER’ button twice in succession,  To turn off the night light, press the ‘MODE’ and ...
  • Page 3 CETO SMART OPERATION MANUAL    BRAND CODE TABLE    www.cetosmart.com  BG   ...
  • Page 4 CETO SMART OPERATION MANUAL BRAND CODE TABLE www.cetosmart.com...