AGS10 Table of Contents Page Automatic Generator Start (AGS) System Overview System Components Mobile App Menu Bar Status Tab Generator Operation Status Control Menu Run TIme Minutes Settings Start Temperature Settings Quiet Time Settings Door Lock / Unlock Remote Controller (Key Fob) Registration...
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: Namsung AGS system provides either manual control or automatic control of built in generator. The purpose of AGS system is to automatically start and stop generator under predetermined setting parameters such as house battery voltage, temperature, and period of quite time and minimum/maximum run time.
AGS10 System Overview AGS starts/stops a generator under preset conditions listed below (Mobile APP Control & Remote control). 1) Measured temperature is higher than start temperature. 2) Reading voltage reaches at preset low voltage and charges up to maximum volt- ages.
RV vehicle and the generator itself. The Generator running signal received from the generator is a 12V analog signal that allows the AGS10 module to determine if the generator is currently operational. By being directly connected to the house battery, the module receives power and can also monitor the charging status of the house battery.
Page 6
AGS10 System Components AGS Switch The AGS Switch performs the function of enabling or disabling the AGS feature. It is powered by connecting to 12V and ground and communicates with the AGS module via Bluetooth. When both the module and the...
AGS10 Mobile App Download the mobile app for your device using the QR code provided below. When AGS module is connected to power and the app is opened, the AGS app begins to search the AGS module. Enter the 6-digit passcode registered in the AGS module.
AGS10 Menu Bar Tab menu can be selected to move to the screen to use features. Settings Door Lock/Unlock Control Status When using an Auto Generator Start (AGS) system, there are several considerations and precautions that customers should be mindful of: Safety Precautions: Customers should be aware of safety precautions related to the AGS system.
AGS10 Status Tab Status Tab displays status of AGS mode and generator operation. Status Tab displays status of AGS mode and generator operation. By clicking on toggle button, AGS will be on and off. In Manual mode, generator can be manually started and stopped by touching start/stop button.
AGS10 Generator Operation Status Control Menu Battery Level Enable/Disable Switch. When enabled, the generator starts running at low voltage level and stops at high voltage levels. Decrease start voltage setting value by 0.1V. Voltage Range: 10.5v ~ 12.5v (default: 11.5v) Increase start voltage setting value by 0.1V.
AGS10 Run Time Minutes Decrease minimum generator run time by 10 minutes. Range: 10 ~ 30 minutes (default: 20mins) Increase minimum generator run time by 10 minutes. Decrease maximum generator run time by 10 minutes. 120 ~ 300 minutes (default: 120mins) Increase maximum generator run time by 10 minutes.
AGS10 Door Lock/Unlock This feature is for remotely controlling door lock/unlock functions with mobile app. Lock the RV door. Unlock the RV door. Remote Controller (Key Fob) Registration This page in the app is to set up and register the thermis- tor switch and key fob.
AGS10 AGS Temperature Switch Registration 1. Press REGISTER. 2. The new menu will be opened, and the Press ‘push’ button message will be seen. If the STOP/CANCEL button is pressed, pro- cess will be cancelled. 3. Press the Enable/Disable button on AGS Temperature Switch.
AGS10 Additional Settings Factory Reset - To stop using AGS Temperature sensor, reset the app by pressing Factory Reset. Logout To replace the AGS module or use a dif- ferent mobile device, log out first and log back in with a new passcode.
3 & 4 Door Lock/ Unlock Output (If Applicable) – Door Lock/Unlock control with using Remote key control and the app. 5&6 Generator Start/Stop Output – Using Key fob and AGS app, AGS10 module sends generator start/stop output either to manually start/stop generator or automatically start/stop generator under pre-determined condition. These start/stop outputs are tied parallel with the wire connection between physical generator switch and generator.
AGS10 AGS Switch Wiring The wireless AGS Enable/Disable switch has abuilt in temperature sensor that gives real time temperature reading to the AGS module via Bluetooth. This temperature reading is used for setting auto generator start/stop based on the temperature setting...
Unregistered AGS Switch - AGS Switch must be registered to AGS10 module. If the AGS switch button is not synchronized with app, register as outlined on page 13. This is not a switch malfunction but rather one of the systems displays indicating that AGS Switch LED light is blinking.
Page 19
Check the Door Lock / Unlock wiring - Make sure the door lock and unlock wiring is connected properly. Low RKE (FOB) battery voltage (If AGS10 Door Lock/Unlock Control is Not Working with Key Fob is installed) - Check to see if the battery is low and if needed, replace it.
AGS10 Replacing the Battery To replace the battery, open the key fob cover case. Press and hold the mechanical key release button, and lift up the mechanical key. Open it gently by pulling both sides of the key fob and remove the silicone cover.
Namsung dealer and used in purpose and any obligation, liability, right, claim or the U.S.A. remedy in contract or tort, whether or not arising from the company’s negligence,...