Advertisement

Quick Links

Outdoor 1200 Braai Insert Installation & Operation Manual
Important information ..................................... 2
Cavity / Enclosure construction ....................... 4
Clearances and specifications ........................ 8
Dimensions .................................................... 8
Floor protector requirements .......................... 8
Hebel cell construction ................................. 10
Operation information ................................... 12
Cleaning and maintenance .......................... 14
Outdoor by Metro warranty ........................... 15
Outdoor by Metro accessories ....................... 16
19 Oropuriri Road // New Plymouth 4312
info@metrofires.co.nz // www.metrofires.co.nz

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Braai 1200 and is the answer not in the manual?

Questions and answers

Summary of Contents for metrofires Braai 1200

  • Page 1: Table Of Contents

    Cleaning and maintenance ......14 Clearances and specifications ......8 Outdoor by Metro warranty ......15 Dimensions ............ 8 Outdoor by Metro accessories ....... 16 Floor protector requirements ......8 19 Oropuriri Road // New Plymouth 4312 info@metrofires.co.nz // www.metrofires.co.nz...
  • Page 2: Important Information

    WARNING! CAUTION! Important Information Important Information WE HIGHLY RECOMMEND YOU READ THIS ENTIRE • Mixing of appliance or flue-system components from different • sources or modifying the dimensional specification or components MANUAL AS INCORRECT OPERATION, MISUSE AND/OR may result in hazardous conditions. Where such action is considered, LACK OF MAINTENANCE WILL VOID THE WARRANTY the manufacturer should be consulted in the first instance •...
  • Page 3: Stages Of Installation

    Outdoor 1200 Braai Insert Assembly of your Outdoor Braai Your Outdoor 1200 Braai Insert is wrapped in plastic, and tek screwed to a wooden pallet. Having removed the packaging and located this manual, please familiarise yourself with the illustration opposite and installation detail on the following pages.
  • Page 4: Cavity / Enclosure Construction

    Specifications were correct at the time of printing but may alter and those detailed within should be used only as a guide. Full assembly and installation instructions are detailed in the Outdoor Installation manuals available at metrofires.co.nz. If in doubt, please consult your local Metro Fires stockist or visit metrofires.co.nz.
  • Page 5: Assembling Your Outdoor 1200 Braai

    Outdoor 1200 Braai Insert assembly Installation location Step 1 Evaluate the location for your outdoor fire, surroundings, and neighbouring properties. The land’s topography will have a bearing on how the wind and overall environment may affect the fire and flue system. Consider surrounding trees, neighbouring property boundaries, buildings, or wooden fences.
  • Page 6: Outdoor 1200 Braai Flue System Installation

    Outdoor 1200 Braai Insert flue kit installation WARNING! CAUTION! Important Information Important Information • WE STRONGLY RECOMMEND USING A QUALIFIED • Mixing of appliance or flue-system components from different sources or modifying the dimensional specification or components INSTALLER TO ASSEMBLE THE FIRE AND ERECT THE may result in hazardous conditions.
  • Page 7 Outdoor 1200 Braai Insert flue kit installation Flue installation Plaster/finish the non-combustible structure if necessary. Fit the side vent covers. Having positioned your Outdoor 1200 Braai Insert in the desired location, check to ensure the fire and floor protector (if applicable) have adequate Fit your custom made chimney cap (flashing cap).
  • Page 8: Clearances And Specifications

    Outdoor 1200 Braai Insert flue clearances 1 metre minimum if clear within 3 metres 3 metres of flue top or less More than 3 metres Any nearby structure 3 metres 600mm 3 metres minimum 1 metre minimum if clear within 3 metres of flue top 300mm...
  • Page 9: Wall Installation

    Specifications were correct at the time of printing but may alter and those detailed within should only be used as a guide. Full assembly and installation instructions are detailed in the Outdoor Installation manuals. If in doubt, please consult your local Metro stockist or visit metrofires.co.nz.
  • Page 10: Hebel Cell Construction

    Hebel heat cell construction A Hebel heat cell can be constructed around the Outdoor 1200 Insert using 5x Hebel panels. 2400 x 600 x 50mm thick panels are the minimum required for basic heat cell construction for the Outdoor 1200 Insert. Cut and construct your Hebel cell around the fire and gather using the instruction sequence on page 7 making sure when gluing and 5567mm2 designed for a hole cutt size of 200 x 50...
  • Page 11 Hebel Heat Cell cut-out plan - continued Hebel Panels x5 (Recommended minimum panel sizes 2400 x 600 x 50mm) Ember tool assembly instructions Your Outdoor 1200 Braai Insert comes complete with an ember tool. Packed inside the fire is the stainless steel tool head and aluminium handle. The ember tool includes: 1x stainless steel tool head, 1x aluminium handle, 4x M6x8mm stainless steel dome head sockets, 4x 6mm flat washers.
  • Page 12: Operation Information

    WARNING! CAUTION! Important Information Important Information WE HIGHLY RECOMMEND YOU READ THIS ENTIRE • This appliance should be maintained and operated at all times in • accordance with this instruction manual MANUAL AS INCORRECT OPERATION, MISUSE AND/OR LACK OF MAINTENANCE WILL VOID THE WARRANTY •...
  • Page 13: Operating Your Outdoor 1200 Braai

    Operating your Outdoor 1200 Braai Insert Operating your Outdoor 1200 Braai is simple and you will quickly learn how Cooking setup (standard) to get the best from it. First take a minute to familiarise yourself with your new Outdoor 1200 Braai and the cooking accessories supplied with it. The ember maker is located in the centre of the Outdoor 1200 to •...
  • Page 14: Cleaning And Maintenance

    Cleaning and maintenance for your Outdoor 1200 Braai Insert Your Outdoor 1200 Braai Insert will give you many years of efficient service The following parts of the Outdoor 1200 Braai Insert are considered with minimal maintenance if operated correctly using seasoned fuel. Your consumables.
  • Page 15: Outdoor By Metro Warranty

    Warranty details for your Outdoor 1200 Braai Insert Outdoor by Metro fires are manufactured in New Zealand, using the highest • It is critical the fire not be operated with over worn, faulty or missing quality of materials, workmanship and the latest manufacturing techniques, parts, firebricks or burn tray which is why we offer a full 2 year firebox warranty and a 12 month parts •...
  • Page 16: Outdoor By Metro Accessories

    For further details ask your Metro stockist for a copy of the Outdoor by Metro compliment your Outdoor 1200 Braai. See below for the cooking accessories brochure, or visit metrofires.co.nz to download a copy. included with the Outdoor 1200 Braai and other outdoor products within our heating accessory range.