Operating instructions

1. SAFETY REGULATIONS AND INFORMATION

Read these operating instructions carefully before starting work on the
device. Observe the following warnings to prevent malfunctions or
danger to persons.
These operating instructions are to be regarded as part of the device.
The device is only to be sold or passed on together with the operating
instructions.
These operating instructions may be duplicated and distributed to inform
about potential dangers and their prevention.
1

1.1 Hazard levels for warnings

1
1
These operating instructions use the following hazard levels to indicate
1
potentially hazardous situations and important safety regulations:
1
2
2
2
2
2
2
3
4
4
5
5
5
5
5
5

1.2 Staff qualifications

5
The device may only be transported, unpacked, installed, operated,
6
maintained and otherwise used by suitably qualified, trained and
7
authorized technical staff.
8
Only authorized specialists are permitted to install the device, to carry
8
out a test run and to perform work on the electrical installation.
8

1.3 Basic safety rules

8
The safety hazards associated with the device must be assessed again
9
following installation in the final product.
9
Note the following when working on the device:
9
; Do not perform any modifications, additions or conversions on the
device without the approval of ebm-papst.

1.4 Voltage

; Check the device's electrical equipment at regular intervals; see
Chapter 5.2 Safety inspection.
; Replace loose connections and defective cables immediately.
DANGER
Indicates an imminently hazardous situation which will result in
death or serious injury if the specified actions are not taken.
Compliance with the instructions is imperative.
WARNING
Indicates a potentially hazardous situation which can result in
death or serious injury if the specified actions are not taken.
Exercise extreme caution while working.
CAUTION
Indicates a potentially hazardous situation which can result in
minor or moderate injury or damage to property if the specified
actions are not taken.
NOTE
A potentially harmful situation can occur and, if not avoided, can
lead to property damage.
DANGER
Electrically charged device
Risk of electric shock
→ When working on an electrically charged device, stand on a
rubber mat.
WARNING
Live terminals and connections even with device
switched off
Electric shock

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the R2D225-AV02-15 and is the answer not in the manual?

Questions and answers

Summary of Contents for ebm-papst R2D225-AV02-15

  • Page 1: Table Of Contents

    Note the following when working on the device: 5.3 Disposal ; Do not perform any modifications, additions or conversions on the device without the approval of ebm-papst. 1.4 Voltage ; Check the device's electrical equipment at regular intervals; see Chapter 5.2 Safety inspection.
  • Page 2: Safety And Protective Features

    Operating instructions R2D225-AV02-15 → Wait five minutes after disconnecting the voltage at all poles 1.7 Emissions before opening the device. WARNING CAUTION Depending on the installation and operating conditions, In the event of a fault, the rotor and the impeller will be the sound pressure level may exceed 70 dB(A).
  • Page 3: Intended Use

    Operating instructions R2D225-AV02-15 2. INTENDED USE The device is exclusively designed as a built-in device for conveying air according to its technical data. Any other usage above and beyond this does not conform with the intended purpose and constitutes misuse of the device.
  • Page 4: Technical Data

    Operating instructions R2D225-AV02-15 3. TECHNICAL DATA 3.1 Product drawing All dimensions in mm. Accessory part: inlet ring 96358-2-4013 not included in scope of delivery, other inlet rings on request Max. clearance for screw 5 mm Cable PVC AWG20, 6x crimped splices...
  • Page 5: Nominal Data

    With regard to cyclic speed loads, note that the rotating parts of the device are designed for a maximum of one million load Motor M2D068-DF cycles. If you have special questions, consult ebm-papst for support. Phase Nominal voltage / VAC 3.4 Mounting data...
  • Page 6: Connecting The Cables

    Operating instructions R2D225-AV02-15 CAUTION 4.3 Connecting the cables Voltage The device has external leads. The fan is a built-in component and has no disconnecting switch. ; First connect the "PE" (protective earth). → Only connect the fan to circuits that can be switched off with Connect the cables according to your application.
  • Page 7: Connection Diagram

    Operating instructions R2D225-AV02-15 4.4 Connection diagram Three-phase motor Star connection = U1 = black 2 = V1 = black 1 = W1 = black 3 (thermal overload protector) 2x yellow green/yellow Item no. 14278-5-9970 · ENU · Change 89188 · Approved 2016-04-18 · Page 7 / 9...
  • Page 8: Checking Connections

    Operating instructions R2D225-AV02-15 4.5 Checking connections 5. MAINTENANCE, MALFUNCTIONS, POSSIBLE CAUSES AND REMEDIES ; Ensure isolation from supply (all phases). ; Make sure a restart is impossible Do not perform any repairs on your device. Send the device to ebm- ;...
  • Page 9: Cleaning

    ISO 14001 and rigorously implemented around the world on the basis of German standards. → Please contact ebm-papst for any other questions on disposal. Right from the development stage, ecological design, technical safety and health protection are fixed criteria.