Synca CADI Optimum AIR Manual

Advertisement

Quick Links

Product Description
The CADI Optimum AIR sensor is a direct converting X-ray detector, which converts X-ray photons directly into digital
image data. The CADI Optimum AIR sensor system supports wireless Bluetooth® 5.0 communications protocol and
supports USB 2.0 connectivity to Personal Computers (PCs).
Intended Use
CADI Optimum AIR is intended to be used for a radiographic examination by a dental professional to assist in the
diagnosing of diseases of the teeth, jaw, and oral structures.
The CADI Optimum AIR sensor is a digital wireless sensor that is intended to acquire dental intraoral radiographic
images. The CADI Optimum AIR sensor shall be operated by healthcare professionals, who are ed ucated and competent
in performing the acquisition of dental intraoral radiographs. The CADI Optimum AIR sensor is used in combination with
special positioning devices to facilitate positioning and alignment with the X-ray beam.
CADI Optimum AIR is for use as prescribed by dentists, dental assistants, registered hygienists, or other qualified dental
healthcare personnel trained in the use of the system.
CADI Optimum AIR is intended for use by the general population. Suitability of use of the CADI Optimum AIR is restricted
by the anatomy and size of the patient's oral cavity. Professional judgement must be used to determine whether the
sensor is suitable for use with a particular patient with minimum discomfort based on the anatomy and size of the
patient, and the ability to position the sensor in the oral cavity with minimum discomfort.
Contraindications
This device is not designed, sold, or intended for use except as indicated. The user may not replace or remove any parts
of the system. Only the provided USB cable and antenna are authorized for use with the system.
Safety Precautions
WARNING
Take the necessary steps to protect yourself from radiation. For proper operator positioning,
refer to the 'Instructions for Use' of your intraoral X-ray equipment.
WARNING
Under no circumstances should the dental professional hold the sensor by hand during X -ray
exposure.
Changes or modifications not expressly approved by the party
X-Ray Protection
The rules of dental radiography still apply to digital X-ray systems. Please continue to use protection for your patients. As
a clinician, clear the immediate area when exposing the sensor.
CADI Optimum AIR Sensor
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the CADI Optimum AIR and is the answer not in the manual?

Questions and answers

Summary of Contents for Synca CADI Optimum AIR

  • Page 1 CADI Optimum AIR is intended for use by the general population. Suitability of use of the CADI Optimum AIR is restricted by the anatomy and size of the patient’s oral cavity. Professional judgement must be used to determine whether the sensor is suitable for use with a particular patient with minimum discomfort based on the anatomy and size of the patient, and the ability to position the sensor in the oral cavity with minimum discomfort.
  • Page 2: Cleaning And Disinfection

    CLEANING AND DISINFECTION When cleaning the CADI Optimum AIR sensor or the docking station, follow the cleaning and disinfection protocol described in this section. Cleaning and Disinfection of CADI Optimum AIR Sensor Only use the approved disinfectants with CADI Optimum AIR sensors.
  • Page 3 Cleaning of CADI Optimum AIR Docking Station The CADI Optimum AIR docking station is not intended to be moved or to come in contact with a patient during clinical use. Accordingly, it does not require routine cleaning. If the CADI Optimum AIR docking station becomes soiled or comes into contact with a patient, it should be cleaned using the cleaning agents recommended for the CADI Optimum AIR sensor recommended above.
  • Page 4 Do not submerge the CADI Optimum AIR docking station in any liquid at any time. Do not autoclave the CADI Optimum AIR docking station. Autoclave sterilizers will permanently damage the device. Sensor Barriers and Sleeves Sensor barriers and sleeves (sensor covers) are disposable, and they must not be reused in any circumstances.
  • Page 5 When a CADI Optimum AIR Wireless Sensor is docked, it will then start to pulse blue indicating a charging status. If a CADI Optimum AIR Wireless Sensor is placed onto the Docking Station before it is plugged into the computer, it will not start to pulse until the sensor is removed and then placed back on.
  • Page 6 Click on “Finish” once the installation is done. To bridge the CADI Optimum AIR™ sensor with your Image Management Software, refer to their directions to add the sensor and acquire x-ray images. For assistance or information call CADI support.