ebm-papst A2D160-AB22-06 Operating Instructions Manual
ebm-papst A2D160-AB22-06 Operating Instructions Manual

ebm-papst A2D160-AB22-06 Operating Instructions Manual

Advertisement

Quick Links

A2D160-AB22-06
ASIA PACIFIC SHENGRUI LIMITED
Phone +00852 56261528
info@apacshengrui.com
www.apacfan.com
CONTENTS
Item no. 14533-5-9970 · ENU · Change 230616 · Approved 2021-05-03 · Page 1 / 11
Operating instructions

1. SAFETY REGULATIONS AND INFORMATION

Read these operating instructions carefully before starting work on the
device. Observe the following warnings to prevent malfunctions or
danger to persons.
These operating instructions are to be regarded as part of the device.
The device is only to be sold or passed on together with the operating
instructions.
These operating instructions may be duplicated and distributed to inform
about potential dangers and their prevention.
1

1.1 Hazard levels for warnings

1
1
These operating instructions use the following hazard levels to indicate
1
potentially hazardous situations and important safety regulations:
1
2
2
2
2
2
2
3
4
4
5
5
5
5
6
6

1.2 Staff qualifications

6
The device may only be transported, unpacked, installed, operated,
7
maintained and otherwise used by suitably qualified, trained and
8
authorized technical staff.
9
Only authorized specialists are permitted to install the device, to carry
9
out a test run and to perform work on the electrical installation.
9

1.3 Basic safety rules

9
The safety hazards associated with the device must be assessed again
9
following installation in the final product.
10
The locally applicable industrial safety regulations are always to be
10
observed when working on the device.
Keep the workplace clean and tidy. Untidiness in the work area
increases the risk of accidents.
Note the following when working on the device:
; Do not perform any modifications, additions or conversions on the
device without the approval of ebm-papst.

1.4 Voltage

; Check the device's electrical equipment at regular intervals; see
Chapter 5.2 Safety inspection.
; Replace loose connections and defective cables immediately.
DANGER
Indicates an imminently hazardous situation which will result in
death or serious injury if the specified actions are not taken.
Compliance with the instructions is imperative.
WARNING
Indicates a potentially hazardous situation which can result in
death or serious injury if the specified actions are not taken.
Exercise extreme caution while working.
CAUTION
Indicates a potentially hazardous situation which can result in
minor or moderate injury or damage to property if the specified
actions are not taken.
NOTE
A potentially harmful situation can occur and, if not avoided, can
lead to property damage.
DANGER
Electrically charged device
Risk of electric shock
→ When working on an electrically charged device, stand on a
rubber mat.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the A2D160-AB22-06 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ebm-papst A2D160-AB22-06

  • Page 1: Table Of Contents

    Note the following when working on the device: ; Do not perform any modifications, additions or conversions on the device without the approval of ebm-papst. 1.4 Voltage ; Check the device's electrical equipment at regular intervals; see Chapter 5.2 Safety inspection.
  • Page 2: Safety And Protective Features

    Operating instructions A2D160-AB22-06 WARNING 1.7 Emissions Live terminals and connections even with device WARNING switched off Depending on the installation and operating conditions, Electric shock the sound pressure level may exceed 70 dB(A). → Wait five minutes after disconnecting the voltage at all poles Risk of noise-induced hearing loss before opening the device.
  • Page 3: Intended Use

    Operating instructions A2D160-AB22-06 2. INTENDED USE The device is exclusively designed as a built-in device for conveying air according to its technical data. Any other usage above and beyond this does not conform with the intended purpose and constitutes misuse of the device.
  • Page 4: Technical Data

    Operating instructions A2D160-AB22-06 3. TECHNICAL DATA 3.1 Product drawing All dimensions in mm. Direction of air flow "V" Max. clearance for screw 5 mm Cable PFA AWG18, 1x crimped splice, cable PFA AWG20, 3x crimped splices Item no. 14533-5-9970 · ENU · Change 230616 · Approved 2021-05-03 · Page 4 / 11...
  • Page 5: Nominal Data

    With regard to cyclic speed loads, note that the rotating parts of the device are designed for a maximum of one million load Motor M2D068-BF cycles. If you have special questions, consult ebm-papst for support. Phase ; Use the device in accordance with its degree of protection.
  • Page 6: Connection And Startup

    Operating instructions A2D160-AB22-06 4. CONNECTION AND STARTUP NOTE Water ingress into wires or cables Water ingress at the customer end of the cable can damage the 4.1 Mechanical connection device. CAUTION → Make sure the end of the cable is connected in a dry Cutting and crushing hazard when removing fan from environment.
  • Page 7: Connecting The Cables

    Operating instructions A2D160-AB22-06 4.3 Connecting the cables 4.3.2 Motor protection The device has external leads. WARNING Device has no overheating protection ; First connect the "PE" (protective earth). The device is supplied without any automatic overheating Connect the cables according to your application. When doing so, ●...
  • Page 8: Connection Diagram

    Operating instructions A2D160-AB22-06 4.4 Connection diagram Change of rotation direction by reversing two phases Three-phase motor Star connection Counterclockwise operation = V1 = blue = U1 = black = W1 = brown Clockwise operation = U1 = black = V1 = blue...
  • Page 9: Checking Connections

    Deficient cooling Improve cooling In the event of further malfunctions, contact ebm-papst. 5.1 Cleaning To ensure a long service life, check the fans regularly for proper operation and soiling. The frequency of checking is to be adapted accordingly depending on the degree of soiling.
  • Page 10: Safety Inspection

    6 months Only ferrite magnets and not rare earth magnets are used in external terminal rotor motors from ebm-papst Mulfingen GmbH & Co. KG. Insulation of Visual inspection At least every Replace cables ; Ferrite magnets can be disposed of in the same way as normal iron...
  • Page 11 Electrolytic capacitors ● Dispose of electronic components employing the proper procedures for electronic scrap. → Please contact ebm-papst for any other questions on disposal. Item no. 14533-5-9970 · ENU · Change 230616 · Approved 2021-05-03 · Page 11 / 11...

Table of Contents