Morris BF3 Series Installation & Maintenance Instructions Manual

Semi-recessed bottle fillers

Advertisement

MORRIS GROUP
INTERNATIONAL
BF3
TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:
NOTES TO INSTALLER:
1. Please leave this documentation with the owner of the fixture when finished.
2. Please read this entire booklet before beginning the installation.
3. Check your installation for compliance with plumbing, electrical and other applicable codes.
For current Warranty click hyperlink
Morris Group International assumes no
responsibility for use of void or superseded
data.
Please visit
www.murdockmfg.com
or
www.whitehallmfg.com
for most current
specifications.
7109-709-001
1 of 16
07/30/24 C
Semi-Recessed Bottle Fillers
Surface Mounted Bottle Fillers
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
I N S TA L L AT I O N / M A I N TA N C E I N S T R U C T I O N S
BF3 & BF4 Series
WHBF3 & WHBF4 Series
Semi-Recessed Bottle Filler
1.800.743.8259
Technical Assistance E-Mail: Fieldservice@acorneng.com
Product Warranty
NSF/ANSI/CAN 61
or visit: www.murdockmfg.com/terms-and-warranty
Federal
Federal
Public Law
Public Law
111-380
111-380
(No Lead)
(No Lead)
WHBF4
P.O. BOX 3527 Industry, CA 91744
15125 Proctor Ave Industry, CA 91746
(626) 336-4561
Date: 07/30/24 C

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BF3 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Morris BF3 Series

  • Page 1 2. Please read this entire booklet before beginning the installation. 3. Check your installation for compliance with plumbing, electrical and other applicable codes. For current Warranty click hyperlink Product Warranty or visit: www.murdockmfg.com/terms-and-warranty Morris Group International assumes no Federal Federal responsibility for use of void or superseded Public Law Public Law data.
  • Page 2: Block Out

    3/8" NCT SUPPLY INLET 1-1/4" O.D. WASTE OUTLET NOTE: RIGHT, LEFT, AND REAR WASTE ORIENTATION ARE OPTIONAL IF NEEDED FOR CALLOUTS INDICATED **. MORRIS GROUP INTL. • P.O. BOX 3527 • City of Industry, CA 91744 USA Member of Phone 626-336-4561 7109-709-001...
  • Page 3 ELECTRICAL SERVICE ROUGH 100-240VAC, 50-60Hz DUPLEX RECEPTACLE ARE OPTIONAL IF NEEDED FOR CALLOUTS INDICATED **. FOR 9VDC, 0.8A PLUG-IN POWER SUPPLY MORRIS GROUP INTL. • P.O. BOX 3527 • City of Industry, CA 91744 USA Member of Phone 626-336-4561 7109-709-001...
  • Page 4: Prior To Installation

    (see label on the bottle filler) Fill Spout Aluminum Name Plate Sensor (BF4) Drain Hemispherical Pushbutton (BF3) MORRIS GROUP INTL. • P.O. BOX 3527 • City of Industry, CA 91744 USA Member of Phone 626-336-4561 7109-709-001 Page 4 of 16 Date: 07/30/24 C...
  • Page 5 Outlet Elbow 18" PE Tubing Air-Control Valve Inlet Fitting "Y" Strainer 3/8" O.D. Copper Inlet MORRIS GROUP INTL. • P.O. BOX 3527 • City of Industry, CA 91744 USA Member of Phone 626-336-4561 7109-709-001 Page 5 of 16 Date: 07/30/24 C...
  • Page 6 2169-000-000 1/4: O.D. LLDPE TUBING, BLUE 7012-055-000 FOAM PIPE INSULLATION 7003-670-001 FILTER BRACKET ASSEMBLY MORRIS GROUP INTL. • P.O. BOX 3527 • City of Industry, CA 91744 USA Member of Phone 626-336-4561 7109-709-001 Page 6 of 16 Date: 07/30/24 C...
  • Page 7 VALVE CLOSED WATER INLET VALVE OPEN ITEM PART NUMBER DESCRIPTION 7012-313-000 Wf1 FILTER REPLACEMENT CARTRIDGE MORRIS GROUP INTL. • P.O. BOX 3527 • City of Industry, CA 91744 USA Member of Phone 626-336-4561 7109-709-001 Page 7 of 16 Date: 07/30/24 C...
  • Page 8 Sensor 18" PE Tubing Solenoid Valve Inlet Fitting "Y" Strainer 3/8" O.D. Copper Inlet MORRIS GROUP INTL. • P.O. BOX 3527 • City of Industry, CA 91744 USA Member of Phone 626-336-4561 7109-709-001 Page 8 of 16 Date: 07/30/24 C...
  • Page 9 If the flow volume is less than 16.9 fl oz there will be no count but the volume will accumulate, so that part way through the next cycle the total bottle count will change. ILLUMINATED LCD DISPLAY MORRIS GROUP INTL. • P.O. BOX 3527 • City of Industry, CA 91744 USA Member of Phone 626-336-4561...
  • Page 10 • The “REPLACE FILTER” will no longer appear on the display • Test by actuating the bottle filler, alert will not appear. RESET/MODE BUTTON MORRIS GROUP INTL. • P.O. BOX 3527 • City of Industry, CA 91744 USA Member of Phone 626-336-4561...
  • Page 11 POWER SUPPLY CONNECTION (BLACK CABLES) SENSOR CONNECTION TRANSFORMER SENSOR SENSOR CONNECTION (BLACK & RED CABLES) MORRIS GROUP INTL. • P.O. BOX 3527 • City of Industry, CA 91744 USA Member of Phone 626-336-4561 7109-709-001 Page 11 of 16 Date: 07/30/24 C...
  • Page 12: Push-In Fitting Installation

    While holding the collet in, pull on the PE tubing to remove from the push-in fitting. COLLET MORRIS GROUP INTL. • P.O. BOX 3527 • City of Industry, CA 91744 USA Member of Phone 626-336-4561 7109-709-001...
  • Page 13 6. Periodically remove access panel of cooler and clean out inline “Y’’ strainer MORRIS GROUP INTL. • P.O. BOX 3527 • City of Industry, CA 91744 USA Member of Phone 626-336-4561...
  • Page 14: Battery Pack

    3. Place the battery pack back to mounted location and test for proper operation. Then close bottler filler door and lock. WIRING DIAGRAM: SOLENOID BATTERY PACK RED WIRES SENSOR MORRIS GROUP INTL. • P.O. BOX 3527 • City of Industry, CA 91744 USA Member of Phone 626-336-4561 7109-709-001 Page 14 of 16 Date: 07/30/24 C...