  • Page 2 TBox Series Industrial Internet Data Transmission Terminal Change history Change description Version Release date First release. V1.0 April 2024...
  • Page 3: Table Of Contents

    TBox Series Industrial Internet Data Transmission Terminal Contents Contents Contents ........................ i Safety precautions ....................1 1 Product overview ....................2 1.1 Product features ......................2 1.2 Product specifications ....................3 1.3 Model instruction ......................4 1.4 Port instruction ......................4 1.5 Indicator instruction ....................
  • Page 4: Safety Precautions

    TBox Series Industrial Internet Data Transmission Terminal Safety precautions Safety precautions Before you operate the Internet data transmission terminal, read the safety precautions described in this manual carefully to ensure safe operation. The account and password are the authentication credentials of the platform, ...
  • Page 5: Product Overview

    Product overview 1 Product overview INVT TBox series industrial Internet data transmission terminal is an intelligent IoT 4G wireless data terminal, which can easily achieve remote data collection, remote program loading and unloading, and remote commissioning. It uses public carrier networks to provide wireless long-distance data transmission.
  • Page 6: Product Specifications

    TBox Series Industrial Internet Data Transmission Terminal Product overview 1.2 Product specifications Function Description Supported LTE FDD: Band 1/3/5/8 network LTE TDD: Band 34/38/39/40/41 One RS485 interface One standard RJ45 interface (shared by WAN/LAN, switched through Supported a switch.) interfaces...
  • Page 7: Model Instruction

    TBox Series Industrial Internet Data Transmission Terminal Product overview 1.3 Model instruction TBox - * * - ** Area Default:China Product seriers name EU:European Data acquisition method Wireless communication method Default:485+Ethernet Default:4G+WIFI 0:485 4G:Just support 4G 1:Ethernet Model Description European area,support 4G and wifi wireless...
  • Page 8 TBox Series Industrial Internet Data Transmission Terminal Product overview Indicator identifier Description Flash (ON: 1s; OFF: 1s): RS485 communication is abnormal ON or OFF: System exceptions happened. Power supply indicator 202404 (V1.0)
  • Page 9: Installation

    Installation 2 Installation 2.1 Overview TBox series industrial Internet data transmission terminal must be installed properly to achieve the designed function. Generally, the installation must be done under the guidance of our certified and qualified engineers. Note: Do not conduct installation with the power on.
  • Page 10: Operation Guide

    Google Chrome to go to the login page of the INVT industrial IoT application platform. Enter your account and password on the page in the following figure to log in to the platform. Note: To obtain an account and password, please contact your industry administrator.
  • Page 11 TBox Series Industrial Internet Data Transmission Terminal Operation guide Step 2 In the pop-up dialog box, enter the device information according to the actual situation (device name and Device type are required.) Step 3 Scroll the page down to enter the adapter information according to the ID corresponding to the barcode affixed on the surface of the IoT module as well as the password.
  • Page 12: Policy File Making And Burning

    TBox Series Industrial Internet Data Transmission Terminal Operation guide When a network port is used for data acquisition, enter Adapter code  and Adapter key, and set Adapter Type to TBox and LAN. When RS485 and network port are used for data acquisition ...
  • Page 13 TBox Series Industrial Internet Data Transmission Terminal Operation guide Step 2 Open iWoStudio, and create a policy file based on actual device communication parameters and addresses (for details, see the COM&TCP policy file creation method in the iWoStudio help document).
  • Page 14: Device Installation And Wiring

    TBox Series Industrial Internet Data Transmission Terminal Operation guide 3.1.4 Device installation and wiring Step 1 Equipment required: Networked computer, 4G data transmission terminal, IoT SIM card. Step 2 Check if there is a SIM card in the card socket. By default, the SIM card is inserted in the socket.
  • Page 15 TBox Series Industrial Internet Data Transmission Terminal Operation guide Step 5 After login, go to the Wi-Fi configuration interface. Step 6 Click Open to turn on the Wi-Fi. 202404 (V1.0)
  • Page 16 TBox Series Industrial Internet Data Transmission Terminal Operation guide Step 7 Select a Wi-Fi from the drop-down list. If the required Wi-Fi is not found in the list, click Scan to search. Enter the Wi-Fi password. Step 8 Click Save&Apply to connect and save the Wi-Fi.
  • Page 17: Faqs

    TBox Series Industrial Internet Data Transmission Terminal Operation guide 3.3 FAQs After powering on, the power indicator does not flash or light up. Answer: Check if input voltage VIN and GND are in consistent with the silkprint on the casing.
  • Page 18 6 6 0 0 1 - 0 1 3 2 0...