Summary of Contents for Mikster INDU iMAX 1000-TC-LX

  • Page 1 INDU iMAX 1000-TC-LX USER MANUAL v1.3(5.0)EN ul. Wojkowicka 21, 41-250 Czeladź, Poland tel. +48 32 763 77 77 fax: +48 32 763 75 94 mikster.eu...
  • Page 2: Table Of Contents

    User manual INDU iMAX 1000-TC-LX v1.3(5.0)EN CONTENTS CONTENTS ......................................2 TECHNICAL SPECIFICATIONS ..............................3 INSTALLATION DATA ................................4 PRINCIPLE OF OPERATION OF THE INDU IMAX 1000-TC-LX PANEL ..................5 STARTING THE INDU MAX 1000 ............................... 6 MAIN MENU ....................................8 5.1.
  • Page 3: Technical Specifications

    User manual INDU iMAX 1000-TC-LX v1.3(5.0)EN 1. TECHNICAL SPECIFICATIONS 24V DC ±10% Power supply: • INDU WRC COMBO - compatible; • WRC CPPS-01 - external 24V DC power source required Power 7 W (max 500mA) consumption: Housing: One-piece Front Panel...
  • Page 4: Installation Data

    User manual INDU iMAX 1000-TC-LX v1.3(5.0)EN 2. INSTALLATION DATA www.mikster.eu...
  • Page 5: Principle Of Operation Of The Indu Imax 1000-Tc-Lx Panel

    3. PRINCIPLE OF OPERATION OF THE INDU IMAX 1000-TC-LX PANEL The iNDU iMAX 1000-TC-LX panel is adapted to work with a set of WRC modules and with the iNDU WRC COMBO module. Communication between the executive set and the panel takes place via the RS485 line.
  • Page 6: Starting The Indu Imax 1000

    User manual INDU iMAX 1000-TC-LX v1.3(5.0)EN 4. STARTING THE INDU iMAX 1000 After turning on the power supply, the controller goes into standby mode in STOP mode. Will appear on the display a large, distinct logo with cons appears (MAIN SCREEN): INFO - when pressed, it shows the current date and time as well as the measurements of analog inputs.
  • Page 7 User manual INDU iMAX 1000-TC-LX v1.3(5.0)EN START - after pressing the icon, you can go straight to the selection of the program you want to run. MAIN MENU - after pressing the icon, the main menu appears. FUNCTION BUTTONS F1-F4 – after pressing one of the four icons, the outputs previously assigned to a given state are activated.
  • Page 8: Main Menu

    User manual INDU iMAX 1000-TC-LX v1.3(5.0)EN 5. MAIN MENU In the Menu, we will have (from the left): Settings, Manual mode, Autostart, Program, Login, Start. 5.1. SETTINGS The controller has very extensive configuration functions that allow you to adjust its parameters and the way it works to the individual needs of the user.
  • Page 9: User Functions

    User manual INDU iMAX 1000-TC-LX v1.3(5.0)EN 5.1.1. USER FUNCTIONS In these functions, we can set: time and date, menu language, taring. 5.1.1.1. TIME AND DATE SETTING To set the time and date, select a function „Set time” (password required, default password: 123)
  • Page 10: Language Selection

    User manual INDU iMAX 1000-TC-LX v1.3(5.0)EN 5.1.1.2. LANGUAGE SELECTION To set the language, select the "Language" function. The selection is made by pressing the flag symbol of a given country. 5.1.2. SERVICE 1 (SERVICE FUNCTIONS 1) In these functions we can set: •...
  • Page 11 User manual INDU iMAX 1000-TC-LX v1.3(5.0)EN You can scroll through the list using the arrows or a gesture. To select a cell for editing, click on its name. After selecting the name, a window appears where you can change the value of the cell.
  • Page 12 User manual INDU iMAX 1000-TC-LX v1.3(5.0)EN SETUP CELL TABLE: CELL CELL NAME FACTORY RANGE DESCRIPTION VALUE F 01 RS NO. FOR PC 1..32 The number in the RS-485 network under which the controller is seen by the PC Baud rate RS-485 – connection with PC:...
  • Page 13 User manual INDU iMAX 1000-TC-LX v1.3(5.0)EN CELL CELL NAME RANGE DESCRIPTION FACTORY VALUE Allowable number of minutes between the cleaning F 16 TIME TO WASHING 0..999 [min] process F 17 FREE F 18 ID ON/OFF 0..1 Process ID 0 – off 1 –...
  • Page 14 User manual INDU iMAX 1000-TC-LX v1.3(5.0)EN CELL CELL NAME RANGE DESCRIPTION FACTORY VALUE F 34 REL. NO.FOR END 0..32 0 - off 1..32 - number of the control input or relay for the cycle end condition F 35 MIN CHAMB. SET T -100..999...
  • Page 15 User manual INDU iMAX 1000-TC-LX v1.3(5.0)EN CELL CELL NAME RANGE DESCRIPTION FACTORY VALUE MAN.MODE ON/OFF 0..1 Manual operation of the controller: 0 - off 1 - on ADDITIONAL SET 0..1 It is possible to enter additional data, Appendix 1 and Appendix 2 during editing technological...
  • Page 16 User manual INDU iMAX 1000-TC-LX v1.3(5.0)EN CELL CELL NAME RANGE DESCRIPTION FACTORY VALUE FREE CHAMBER TEMP.MEAS.TYPE 0..1 0 - PT100 1 - as a current input scaling in cells 76 and 77 CORE TEMP.MEAS.TYPE 0..1 0 - PT100 1 - as a current input scaling in cells 78 and 79 CHAMBER TEMP.SCALING MIN...
  • Page 17 User manual INDU iMAX 1000-TC-LX v1.3(5.0)EN CELL CELL NAME RANGE DESCRIPTION FACTORY VALUE F89-EXTERNAL DI MODULE 0..4 Additional DI input module: 0 - not connected 1 - connected 2..4 - not used FREE FREE FREE FREE FREE FREE FREE FREE ATTENTION! Setting the same MIN and MAX values will make it impossible to edit the parameters.
  • Page 18: Step Setup - Setting Steps/Cycles Parameters

    User manual INDU iMAX 1000-TC-LX v1.3(5.0)EN 5.1.2.2. STEP SETUP - SETTING STEPS/CYCLES PARAMETERS Each process controlled by INDU iMAX consists of successive steps. Each step can be assigned a running cycle. 16 cycle settings can be stored in the controller. Define for each cycle: •...
  • Page 19 User manual INDU iMAX 1000-TC-LX v1.3(5.0)EN END-STEP CONDITIONS TABLE Name Step termination condition TIR>TIS cycle end after reaching preset time value TCHR>TCHS cycle end after exceeding preset value of temperature inside chamber TCR>TCS cycle end after exceeding preset value of core temperature HUR>HUS...
  • Page 20: Alarms

    User manual INDU iMAX 1000-TC-LX v1.3(5.0)EN Name Step termination condition cycle end after reaching preset time value, and “end release” must be TIR>TIS AND INN=0 cycle end after reaching preset time value, or after switching off “end TIR>TIS OR INN=0 release”...
  • Page 21 User manual INDU iMAX 1000-TC-LX v1.3(5.0)EN To set the alarm parameters: • Select the "ALARMS" function • Select the alarm you are interested in from the list for editing. ATTENTION! When you start the panel for the first time, the alarm list is default, you need to enter the alarm names and their settings.
  • Page 22: Stop/Pause - Setting Parameters For Stop, Pause, F1-F4

    User manual INDU iMAX 1000-TC-LX v1.3(5.0)EN 5.1.2.4. STOP/PAUSE - SETTING PARAMETERS FOR STOP, PAUSE, F1-F4 There are two special states in the controller: Stop and Pause, and four special states assigned to the F1-F4 buttons, for which we can set: •...
  • Page 23: Output Setup

    User manual INDU iMAX 1000-TC-LX v1.3(5.0)EN 5.1.2.5. OUTPUT SETUP 5.1.2.5.1. DIGITAL OTPUTS - CONFIGURATION OF DIGITAL OUTPUTS (RELAY) Each of the 32 relays has individually adjustable operating parameters. The operation of each relay is defined by: • Name • Icon •...
  • Page 24 User manual INDU iMAX 1000-TC-LX v1.3(5.0)EN Timing types of relays operation: • always off: the relay is always off • always on: the relay is on, it works according to the declared time type: 1. On-delayed, relay turns on after Ta time 2.
  • Page 25 User manual INDU iMAX 1000-TC-LX v1.3(5.0)EN 4. Start pulses =0. The relay turns on and off according to the times Ta and Tb. It starts off. Regulator types: 1. Heating access www.mikster.eu...
  • Page 26 User manual INDU iMAX 1000-TC-LX v1.3(5.0)EN 2. Cooling access 3. Heating hysteresis 4. Cooling hysteresis www.mikster.eu...
  • Page 27: Analog Outputs

    User manual INDU iMAX 1000-TC-LX v1.3(5.0)EN 5. Pulse counter - counts pulses from the selected control input Selection of the number of the control input for the counter is made through the settings in the MEASURE CHANNEL column (In1 …In10) and the SET VALUE column (1..19).
  • Page 28 User manual INDU iMAX 1000-TC-LX v1.3(5.0)EN • Enter a name for analog output • Select the type of work of the analog output Analog output work configuration: 1. Output type: - ANALOG OUT OFF (Output disabled) – the output is inoperative;...
  • Page 29: Pid Controller

    User manual INDU iMAX 1000-TC-LX v1.3(5.0)EN 5.1.2.5.3. PID CONTROLLER In INDU iMAX 1000 we can configure 5 settings of the PID controller: • In the OUTPUTS CONFIGURATION menu, select the icon “PID regulator” . From the list, select the PID you want to configure: •...
  • Page 30: Activating The Pid Controller

    User manual INDU iMAX 1000-TC-LX v1.3(5.0)EN 5.1.2.5.4. ACTIVATING THE PID CONTROLLER For the selected digital output to work, the following settings must be configured based on the PID controller: 1. Time type 2. Regulator type - set the PID 3. Measure channel - select the previously configured PID controller (own number) To confirm a change in the configuration, press the key 5.1.2.6.
  • Page 31: Service 2 (Service Function 2)

    User manual INDU iMAX 1000-TC-LX v1.3(5.0)EN 5.1.3. SERVICE 2 (Service function 2) This is where you will find advanced service settings. 5.1.3.1. CARD SEARCH When starting the panel for the first time or as a result of changing the number or types of connected executive modules (COMBO, WRC) or when not all I/O modules connected to the device have been found, the "Card Error"...
  • Page 32: Output Test - Test Of Digital Outputs And Inputs

    User manual INDU iMAX 1000-TC-LX v1.3(5.0)EN To do this, press the "Search for cards" button . The panel will perform a search procedure to update the current configuration of the connected I/O boards. The card search option is available from Menu/Settings/Service 2 (password required, default password: 123) or displayed automatically after detecting changes in the I/O card configuration.
  • Page 33: Aout Test - Test Of Analog Outputs

    After this operation, the selected analog output will be set to a current value corresponding to the setting. 5.1.3.4. UPDATE To start updating the INDU iMAX 1000-TC-LX firmware, insert an external data carrier (properly programmed) into the USB port of the controller and select the functions “UPDATE”...
  • Page 34: Backup / Restore

    Select the “Factory Reset” • Confirmation will be displayed on the screen • To confirm press “OK” ATTENTION! All changes made to the panel will be deleted. The custom start screen logo will be restored to the factory one – MIKSTER. www.mikster.eu...
  • Page 35: Wash Program

    User manual INDU iMAX 1000-TC-LX v1.3(5.0)EN 5.1.4. WASH PROGRAM To set the configuration of the "Wash program”: • Select the "Wash program" function . The program requires entering the input code (default code: 123). • Proceed in the same way as when programming technological steps (see section: 5.4 PROGRAM - PROGRAMMING OF TECHNOLOGICAL PROCESSES), the only difference is the possibility to choose from technological steps intended specifically for the "Washing program”...
  • Page 36: Manual Mode

    User manual INDU iMAX 1000-TC-LX v1.3(5.0)EN 5.2. MANUAL MODE In the Manual mode option we have the option of starting a selected step from the program. Select the step you want to run from the list. Then we enter the values that the controller signals to us by clicking on their window.
  • Page 37: Program - Programming Of Technological Processes

    User manual INDU iMAX 1000-TC-LX v1.3(5.0)EN At the specified time, the controller will automatically start the execution of the appropriate program from the first step. While the controller is waiting for the process to start, no changes can be made to the settings.
  • Page 38 User manual INDU iMAX 1000-TC-LX v1.3(5.0)EN • First enter the name of the program (click on the current name of the program) • Confirm with the button „OK” Then edit the program: • In the "Select step" column, select the step that will be edited.
  • Page 39 User manual INDU iMAX 1000-TC-LX v1.3(5.0)EN • Confirm with "OK" Then enter further parameters: • Set step time • Set chamber temperature • The set temperature of the bar • Set humidity • "Delta" parameter INDU iMAX has the ability to adjust the chamber temperature increase as a function of time [°C/min] (fish smoking technology) or the chamber temperature increase as a function of the bar temperature [Tk/Tb] (temperature difference brewing).
  • Page 40: Login - Users

    User manual INDU iMAX 1000-TC-LX v1.3(5.0)EN After completing the above steps, editing a specific Step in a given Technology Program has been completed. The introduced changes should be confirmed by pressing the "OK" button . The Step parameters were saved in the edited program.
  • Page 41 User manual INDU iMAX 1000-TC-LX v1.3(5.0)EN • Enter new password • Confirm the new password: To change the existing password, first enter the old one, then press the word Password and enter the new one, similarly as when assigning a new password.
  • Page 42 User manual INDU iMAX 1000-TC-LX v1.3(5.0)EN The logged in user has the option of blocking the controller during operation so that no unauthorized changes are made. To do this, press the open padlock icon , when we do this all buttons on the screen will be locked. To remove the lock, press...
  • Page 43: Start - Execution Of The Program Stored In Memory

    User manual INDU iMAX 1000-TC-LX v1.3(5.0)EN 6. START - EXECUTION OF THE PROGRAM STORED IN MEMORY If the previous process has been completed or it is the first run, then the process is as follows: In order to execute a program previously saved in the controller's memory, it is necessary to: •...
  • Page 44: Editing The Set Parameters During The Controller Operation

    User manual INDU iMAX 1000-TC-LX v1.3(5.0)EN 6.1. EDITING THE SET PARAMETERS DURING THE CONTROLLER OPERATION It is possible to correct previously set parameters during program execution by the controller. To do this, you should (during the implementation of the program): •...
  • Page 45: Stop - Stopping The Execution Of The Program

    User manual INDU iMAX 1000-TC-LX v1.3(5.0)EN 6.2. STOP - STOPPING THE EXECUTION OF THE PROGRAM You can also interrupt program execution temporarily: • Press the "PAUSE" key • The controller stops the execution of the program and the diode next to the "PAUSE"...