BBB TERREPOWER ONTILITY EASY BATTERY User Manual

Battery 24v 10 kwh

Advertisement

Available languages

Available languages

Quick Links

EASY BATTERY
10 kWh
24 V
User Manual
MANUAL DE
INSTRUCCIONES

Advertisement

Chapters

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TERREPOWER ONTILITY EASY BATTERY and is the answer not in the manual?

Questions and answers

Summary of Contents for BBB TERREPOWER ONTILITY EASY BATTERY

  • Page 1 EASY BATTERY 10 kWh 24 V User Manual MANUAL DE INSTRUCCIONES...
  • Page 2 MANUAL ONTILITY EASY BATTERY 10 kWh...
  • Page 3: Table Of Contents

    MANUAL ONTILITY EASY BATTERY 10 kWh 24 V Es necesario leer este manual antes de realizar la instalación de la batería. Versión 2.0 - 07.2024 Este manual detalla las baterías Ontility Easy Battery 10 kWh 24V con células NMC prismática. Lea este manual antes de intentar instalar la batería y siga las instrucciones cuidadosamente durante el proceso de la instalación.
  • Page 4: Introducción

    1. Introducción Las baterías de litio ONTILITY EASY BATTERY 10 kWh 24V un proyecto de TerrePower de almacenamiento de energía fabricada en España. EASY BATTERY 10 kWh se fabrican para sistemas de 24V, 48 V y la EB 10 kWh HV se fabrica para sistemas de 87V.
  • Page 5: Especificaciones Y Dimensiones

    1.2 Especificaciones y dimensiones Parámetros principales Easy Battery 24V 10 kWh Capacidad 10 kWh (360 Ah) Voltaje Nominal 29,2 Vdc Rango Voltaje funcionamiento min/máx. 21,6 - 33,6 Rango Voltaje Recomendado 24 - 33 Vdc Intensidad máxima de carga o descarga 125 A Potencia máxima 3000 W...
  • Page 6: Panel Frontal

    1.3 Panel frontal Interruptor ON / OFF Los conectores de la batería se conectan a presión y se desconectan presionando un pequeño botón que tiene cada conector. Para evitar daños en los conectores, el circuito debe de estar abierto cuando se conecte o desconecte a la batería 2.
  • Page 7: Instalación

    Las conexiones en paralelo de v arias baterías se deben de realizar mediante platinas de cobre. La batería se envía totalmente activada y lista para su funcionamiento. Asegurase de que no haya cortocircuito en los elementos externos. No se puede conectar la batería a la alimentación A C directamente. Conecte la batería a tierra.
  • Page 8: Conexión Al Bms

    5. Conexión al BMS Para poder conectarse al BMS y poder monitorizar los datos de la batería se debe de instalar la app para dispositivos móviles. Escanee el código QR para descargar e instalar la app. El código QR se encuentra a continuación: DESCARGUE SU APP PARA IOS DESCARGUE SU APP PARA ANDROID Conexión:...
  • Page 9: Situaciones De Emergencia

    6. Situaciones de emergencia 1. Batería Si el paquete de batería pierde electrolitos, evite el contacto con el líquido. Si queda expuesto a la sustancia filtrada, realice inmediatamente las acciones que se describen a continuación en cada caso: • Inhalación: Evacuar el área contaminada y buscar atención médica. •...
  • Page 10: Limitación De Responsabilidad

    7.2 Limitación de responsabilidad. La garantía sería inaplicable, si el defecto o fallo en el desempeño del producto es atribuible a un mal uso, abuso, accidente o incumplimiento de las condiciones del manual. TerrePower puede exigir pruebas completas del producto, fotos y videos de la instalación. Si impugna la verificación de la reclamación por parte de TerrePower, el producto debe ser evaluado por un laboratorio de la UE de pruebas de certificado o una empresa de pruebas de terceros certificada.
  • Page 11 ONTILITY EASY BATTERY 10 kWh 24 V USER MANUAL It is manadatory to read this manual before performing the battery installation. Version 2.0 - 07/2024 This manual details the Ontility Easy Battery 10 kWh 24 V batteries with Prismatic NCM Cells. Please read this manual before attempting to install the battery and follow the instructions carefully during the installation process.
  • Page 12: Introduction

    1. Introduction The lithium batteries ONTILITY EASY BATTERY 10 kWh 24V are TerrePower`s project for energy storage manufactured in Spain. ONTILITY EASY BATTERY 10 kWh are manufactured for 24 V systems. They are specially designed for both off-grid and grid- connected Photovoltaic (PV) applications.
  • Page 13: Specifications And Dimensions

    1.2 Specifications and dimensions Main Parameters Easy Battery 24V 10 kWh Capacity 10 kWh (360 Ah) Nominal Voltage 29,2 Vdc Operating voltage range min/max 21,6 - 33,6 Operating voltage recommended 24 - 33 Vdc Maximum charge or discharge current 125 A Maximum power 3000 W Life expectative...
  • Page 14: Front Panel

    1.3 Front panel SWITCH ON / OFF The battery connectors are connected by pressing and disconnected by pressing a small button on each connector. To To avoid damage to the connectors, the circuit must be open when connecting or disconnecting to the battery 2.
  • Page 15: Installation

    Parallel connections of several batteries should be made with copper plates. The battery is shipped fully activated and ready for operation. Make sure that there is no short-circuit in the external elements. The battery cannot be connected to AC power directly. Ground the batter y.
  • Page 16: Connection To Bms

    5. Connecting to the BMS In order to connect to the BMS and monitor the battery data, the app for mobile devices must be installed. Scan the QR code to download and install the app. The QR code can be found on the below: DOWNLOAD YOUR APP FOR IOS DOWNLOAD YOUR APP FOR ANDROID Connection:...
  • Page 17: Emergency Situations

    6. Emergency situations 1. Leaking battery If the battery pack leaks electrolytes, avoid contact with the liquid. If exposed to the leaked substance, immediately per- form the actions described below in each case: Inhalation: Evacuate the contaminated area and seek medical attention. •...
  • Page 18: Limitation Of Liability

    7.2 Limitation of liability. The warranty would be inapplicable, if the defect or failure of the product to perform is attributable to misuse, abuse, accident or failure to comply with the conditions of the manual. TerrePower may require complete product testing, photos and installation videos. If you contest the verification of the claim by TerrePower, the product must be evaluated by an EU certified testing laboratory or a certified third party testing company.
  • Page 19 MANUAL ONTILITY EASY BATTERY 10 kWh...
  • Page 20 EASY BATTERY 10 kWh MANUAL DE INSTRUCCIONES USER MANUAL AMIGANET SLU C/ Cartografía 20, 41015 Sevilla, Spain VAT Nº ES-B91011510...

This manual is also suitable for:

422063