8545-1215-0M Rev A 825-SIB Installation Manual...
Page 3
INTRODUCTION This manual serves as your guide for installing the 825-SIB Scale Input Board in the Gen2 825 Stainless Steel Weight Indicator, 825 Desktop Weight Indicator, 825 No Screen Weight Indicator, and the 900UPS Systems. Please read it carefully before beginning the installation and keep it available for future reference.
3/4 inch. 6. Now, remove 1/4 inch of insulation from the end of each of the six wires (with sense leads) or four Figure No. 4 wires (without sense leads). 8545-1215-0M Rev A 825-SIB Installation Manual...
Page 6
1/4 inch Figure No. 5 7. Remove the screw securing the 825 Scale Input Board (825-SIB) to the main PC board and then lift the 825-SIB straight up to remove it from the base enclosure. See Figure No. 6. 8. Remove the 7-connector terminal from the 825-SIB. (Hold the board in place, grasp the terminal block connector, and lift straight up away from the board).
Page 7
Wire 14. The shield wire is secured when tightening the gland connector nut. Do not overtighten the connector but make certain it is snug. See Figure No. 10. Figure No. 10 Shield Wire 8545-1215-0M Rev A 825-SIB Installation Manual...
+SENS, -SENS terminals of the load cell trim board (or the section seal trim board). For the 825-SIB to use the sense wires, the -SENS and +SENS jumpers J1 and J3 must be open (on one pin only) or removed. Refer to Figure No. 12 for the location of these jumpers.
Page 9
J2 (DEAD LD) - DEAD LOAD BOOST JUMPER For scales with extremely low dead loads (less than 10% of the combined load cell capacity), connect the DEAD LD (dead load boost) jumper J2 (near the P3 terminal block). 8545-1215-0M Rev A 825-SIB Installation Manual...
Page 10
CLOSING THE FRONT DISPLAY PANEL After all terminations have been made. 1. Reinstall the 825-SIB into the rear enclosure and secure it to the main PC board with the screw removed Figure No. 13 earlier. See Figure No. 13. 2. Remove the excess cable from the rear enclosure and securely tighten each of the cable gland connectors.
STATEMENT OF LIMITED WARRANTY WARRANTY TERMS Cardinal Scale Manufacturing Company warrants the equipment we manufacture against defects in material and workmanship. The length and terms and conditions of these warranties vary with the type of product and are summarized below:...
Page 12
This warranty sets forth the extent of our liability for breach of any warranty or deficiency in connection with the sale or use of our product. Cardinal will not be liable for consequential damages of any nature, including but not limited to loss of profit, delays or expenses, whether based on tort or contract.
Page 13
8545-1215-0M Rev A 825-SIB Installation Manual...
Page 14
Cardinal Scale Mfg. Co. 102 E. Daugherty, Webb City, MO 64870 USA Ph: 417-673-4631 or 1-800-641-2008 Fax: 417-673-2153 www.cardinalscale.com Technical Support: 1-866-254-8261 E-mail: tech@cardet.com Printed in USA 8545-1215-0M Rev A 825-SIB Installation Manual 8545-1215-0M Rev-A 08/24...