Page 1
INSTRUCTION, USE AND MAINTENANCE HAND - BOOK Machine: STEAM GENERATOR Type: GP.92.5 O.M.E.C Snc di Carnevale Renato & C. - Via dell’Artigianato, 3/5/7 - 20835 Muggiò (MB) - Italy Tel. +39-039-793740 - Fax +39-039-2780689 - E-mail export@omec-snc.com Web site www.omec-group.com...
I N D E X SIDE I WARNINGS, PRECAUTIONS AND GENERAL ADVICES Page No. 1.1.1 Warnings 01/11 1.2.1 Precautions 01/11 SIDE II PRODUCT DESCRIPTION 1.3.1 General advices 01/11 2.1.1 Technical data 01/11 2.2.1 External body description 01/11 2.3.1 Boiler description 01/11 2.4.1 Heating element description...
Page 3
(due to bad carrying). b) Follow carefully the instructions for installing the machine. c) The OMEC STEAM CLEANER TYPE GP.92.5 must be used only by a skilled worker, and therefore machine ONLY AFTER HAVING...
2006/95/EC Standards - Low voltage. b) The OMEC STEAM CLEANER TYPE GP.92.5 must work with DEMINARALIZED water or with water coming from the hydro plant through a anti-lime / water softener. ABSOLUTELY AVOID...
(hum) plays, the red led (7) lights up meaning the total absence of OMEC IS NOT GUILTY FOR A WRONG OR IMPROPER US OF ITS water in the tank. In this event the machine must be immediately switched off and fill the boiler again.
Page 6
3.5.1 HOW TO FILL THE WATER IN THE TANK - Page 4/11 –...
Page 7
3.6.1 PICTURE NO. 1 1 – OUTGOING STEAM ACTUATOR 9 - PISTOL STEAM ACTUATOR 2 – QUANTITY STEAM REGULATING COCK 10 – STEAM PRESSURE GAUGE 3 – ELECTRO-VALVE 11 – WATER UNLOADING COCK 4 - SAFETY WATER LOADING PLUG 5 - MAX. PRESSURE LED FASTENING SCREWs 6 - WATER LEVEL LED OF THE...
Page 8
3.6.2 PICTURE NO. 2 - TAV A 3.6.3 PICTURE NO. 2 - TAV B - Page 6/11 –...
Page 10
ORANGE LED D.10 FASTON TAV B GP.92.4.32 RED LED D.10 FASTON TAV B SD.84.53 GREEN BIPOLAR ACTUATOR TAV B GP.92.5.71 WATER GAUGE - DIAM. 40 TAV A GP.92.4.04 CONTROL PANEL TAV B GP.92.3.76 LOW TENSION CIRCUIT BOARD V.18 TAV B GP.92.3.70...
Screw the holder-fuse cover properly. c) Replace the fuse with one of the same value. TROUBLES: The OMEC STEAM CLEANER TYPE GP.92.5 does not heat the water and does not reach the pressure. CAUSES: a) The manual reset thermostat (67) has worked due to a too high temperature happened previously.
Page 12
WARNING LIGHT BOILER THERMOSTAT MANUAL RESET THERMOSTAT BOILER HEALTING ELEMENT STEAM SOLENOID VALVE AIR PRESSURE SWITCH MICRO-SWITCH FUSE TERMINAL-HOLDER SOUND ALARM 6.1.1 STANDARDS - Page 10/11 – Our STEAM CLEANER TYPE GP.92.5 is manufactured in accordance with the Machine Directive:...
Page 13
2006/42/EC with the following Standards: 88/642/EC 2014/30/UE EMC (Electro-magnetic Compatibility) 2014/35/UE (Low Voltage) 9368/EC UNI EN 60204-1 UNI EN 60204-1/A1 PED 97/23 - 87/404/EC (Pressure European Directive) 6.2.1 WASTE The MACHINE life essentially depends on the preservation, using, maintenance and life time of its components.