Questions and answers
Summary of Contents for AQUISENSE PearlAqua Micro B
Page 1
PearlAqua Micro ™ PearlAqua Micro ™ User Manual Models B & C Aug 2023 REV8.0.2023 PearlAqua Micro User Manual...
Page 2
Description • Delivers UV Doses up to 70 mJ/cm The PearlAqua Micro product lines combine best-in- class UV LEDs with Aquisense’s industry leading • Water flow rates up to 9 lpm product designs. The compact size of these products • High pressure, 120 psi, rated enable UV water disinfection to be fully integrated •...
1. Table of Contents 1. Table of Contents ...................... 3 2. Safety ........................4 General ......................... 4 Safety Label ......................... 4 3. Installation ......................... 5 General Recommendations ..................5 Procedure ........................5 4. Product Identification ....................6 Serial Number ......................6 Model Number ......................
2. Safety This device produces harmful ultraviolet (UV) radiation. Direct contact with UV radiation could damage the eyes and/or skin. Do not look directly into inlet or outlet ports without the use of UV resistant safety glasses. UV Exposure Risk General •...
3. Installation PearlAqua Micro B and C models installed in preferred orientation General Recommendations • Read all installation instructions before beginning. • Do not apply power to the PearlAqua Micro without flowing water. • Install according to all local plumbing and electrical regulations.
4. Product Identification Each PearlAqua Micro is labeled with a unique serial and model number. This label is typically located on the wire harness NOTE: Not all feature combinations available Serial Number Model Number Power and reactor size 03B, 06B, 03C, 06C, 09C, 12C LED Information Sensor options...
5. Technical Specifications Recommended Operational Conditions Parameter Value Unit 12V models Input Voltage Volt 24V models Flow Rate 1 (0.26) lpm (gpm) Water Temperature 25 (77) °C (F) Ambient Temperature 25 (77) °C (F) UV Transmittance >90 Particulate Size <10 micron Hardness <(7/120)
Electrical Specifications Parameter Conditions Min Typ Max Units 12V models 11.4 V Input Voltage 24V models 21.6 Power Consumption See model characteristics table Input Capacitance All models 12V models Inrush Current 24V models Optional Power Supply Input Voltage Output Voltage Output Power Thermistor Sensor Resistance...
Disinfection Specifications Parameter Conditions Min Typ Max Units PAQ-xxx-43x, 25C 10000 Operating Lifetime PAQ-xxx-45x, 25C 8000 hours PAQ-xxx-47x, 40C 2000 UV Dose See Performance Graphs (1) End of life defined as 70% of starting UV flux (2) Temperature as reported by thermistor sensor Mechanical Specifications Parameter ...
13.8 PAQ-3B-x30 PAQ-3B-x31 PAQ-3B-x50 PAQ-3B-x70 PAQ-6B-x50 PAQ-6B-x70 Contact Aquisense PAQ-12C-x50 (1) “x” indicates wildcard value, only first 9 characters of model number considered (2) as determined by part number (3) Measured at recommended input voltage REV8.0.2023 PearlAqua Micro User Manual...
Page 12
UV LED Output power degradation over total operating time Head Loss Curve PearlAqua Micro B models - 3/8" fluid connection Flow Rate (LPM) Head Loss Curve PearlAqua Micro C models - 3/8" fluid connection Flow Rate (lpm) REV8.0.2023 PearlAqua Micro User Manual...
6. Components B & C models C models Standard Enclosure Horizontal Enclosure 3/8” fluid connections 3/8” fluid connections Name Detail ID Water Inlet Water Outlet Wire Harness Reactor Chamber Mounting bracket 2 x 5mm diameter mounting holes REV8.0.2023 PearlAqua Micro User Manual...
7. Dimensions B models C models Standard enclosure Standard enclosure 3/8” fluid connection 3/8” fluid connection Dimensions in mm Dimensions in mm C models Horizontal enclosure 3/8” fluid connection Dimensions in mm REV8.0.2023 PearlAqua Micro User Manual...
8. Pinout NOTE: Alternate and custom configurations available Flying Leads Wire gauge: 22 AWG Wire gauge: 28 AWG Molex Mini-Lock JST XHP Part number: 0511030400 Part number: XHP-4 Name Color Description Input voltage positive Black Input voltage ground / Common TH0, TC0 models LED Health Sensor SensorA White/Yellow...
9. Usage Example Applications Inlet Disinfection This method leaves the disinfection outside the device or process, leaving an opening for bacteria growth at any point in the system. The UV LED system is easier to replace but with lamp lifetimes of up to 10,000 hours, the need to replace is less frequent when compared to conventional mercury lamps.
LED Health Sensor LED Health Sensor Example Application TH0 models Notes • Refer to Section 4 for expected VHEALTH values. • VHEALTH measurement method should have an input impedance exceeding 10K ohms. • Do not exceed 5mA current-input or current- draw from LED Health Sensor pin.
Refer to performance graphs for selected counts High flow rate device model Lamp has reached end of life Contact AquiSense for replacement Ensure unit is being used regularly. If unit Biofilm growth or retrograde might have long periods without normal contamination within unit usage consider periodic pulsing of device.
10. Theory UV-C Water Disinfection Ultraviolet (UV) water disinfection technology has become an increasingly popular tool in water treatment over the past three decades, due in part to its ability to provide treatment without the use of harmful chemicals. UV represents wavelengths that fall between visible light and x-ray on the electromagnetic spectrum.
Owner or by other third parties or from defects in designs or specifications furnished by, or on behalf of, the Owner by a person other than AquiSense. In addition, this warranty shall not apply to Equipment that has been altered or repaired by anyone except AquiSense, their Authorized representative, or personnel acting under specific instructions from AquiSense.
Page 22
Unlike mercury vapour UV-C lamps, the lifetime of UV-C LEDs is not affected by on/off cycles. However, like all light sources, LEDs are subject to aging over time. AquiSense Technologies have engineered an integrated UV-C LED lamp module that contains: power regulation, temperature management, temperature monitoring, and intensity monitoring.
12. Legal Terms for Product Usage In using AquiSense UV-LED products and components, on behalf of the Company, using this document and the PearlAqua Micro product agrees to follow the items listed below. In this document, “UV LED” means any LEDs that emit ultraviolet light with a peak wavelength shorter than 400nm.
13. Change Log Vers Table/Item Change Date New Format Release Sept 19, 2022 Updated Technical Specifications for all Products Updated Power draw estimates for all models August 29, 2023 REV8.0.2023 PearlAqua Micro User Manual...