2 zones kit heating only 2 direct zones 1 direct zone e 1 mixed zone

Advertisement

Available languages

Available languages

Quick Links

KIT 2 ZONE SOLO
RISCALDAMENTO
2 zone dirette
1 zona diretta e 1 zona miscelata
2 ZONES KIT
HEATING ONLY
2 direct zones
1 direct zone e 1 mixed zone
COD. 3.035333 - 3.03533 4
IT
Istruzioni e avvertenze
IE
Instructions and
warnings

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 3.035333 and is the answer not in the manual?

Questions and answers

Summary of Contents for Immergas 3.035333

  • Page 1 KIT 2 ZONE SOLO RISCALDAMENTO Istruzioni e avvertenze 2 zone dirette 1 zona diretta e 1 zona miscelata 2 ZONES KIT HEATING ONLY Instructions and warnings 2 direct zones 1 direct zone e 1 mixed zone COD. 3.035333 - 3.03533 4...
  • Page 2 Gentile Cliente, Ci complimentiamo con Lei per aver scelto un prodotto Immergas di alta qualità in grado di assicurarLe per lungo tempo benessere e sicurezza. Quale Cliente Immergas Lei potrà sempre fare affidamento su un qualificato Servizio di Assistenza Autorizzato, preparato ed aggiornato per garantire costante efficienza ai Suoi prodotti.
  • Page 3: Table Of Contents

    INDICE Installazione dispositivo ............4 Descrizione dispositivo............4 Avvertenze di installazione........... 4 Dimensioni principali............5 Allacciamento idraulico............6 Allacciamento elettrico............6 Schemi di installazione............7 Messa in servizio del dispositivo.......... 7 Dimensionamento degli impianti........7 Kit disponibili a richiesta.
  • Page 4: Installazione Dispositivo

    In caso di anomalia, guasto od imperfetto funzionamento, il disposi- tivo deve essere disattivato ed occorre chiamare un tecnico abilitato DISPOSITIVO (ad esempio il centro Assistenza Tecnica Immergas, che dispone di preparazione tecnica specifica e dei ricambi originali). Astenersi 1.1 DESCRIZIONE DISPOSITIVO.
  • Page 5: Dimensioni Principali

    1.3 DIMENSIONI PRINCIPALI. Legenda: RG - Ritorno generatore (G 1”) MG - Mandata generatore (G 1”) V - Allacciamento elettrico X - Fori per fissaggio fuori muro (pensile) Altezza Larghezza Profondità (mm) (mm) (mm) ST.007963/000 Kit 2 Zone Solo Riscaldamento...
  • Page 6: Allacciamento Idraulico

    ALLACCIAMENTI KIT 2 ZONE DIRETTE Ritorno zona 1 Ritorno zona 2 Mandata zona 2 Mandata zona 1 diretta (G 1”) diretta (G 1”) diretta (G 1”) diretta (G 1”) ALLACCIAMENTI KIT 1 ZONA DIRETTA E 1 ZONA MISCELATA Ritorno zona 1 Ritorno zona 2 Mandata zona 2 Mandata zona 1...
  • Page 7: Schemi Di Installazione

    Sito Internet Im- calore indica circa 1,2 bar. mergas, il Listino Prezzi Immergas o la documentazione N.B.: durante queste operazioni, attivare la funzione sfiato impian- tecnico-commerciale (cataloghi e schede tecniche).
  • Page 8: Pompa Di Circolazione

    1.10 POMPA DI CIRCOLAZIONE. Led circolatore Descrizione Il circolatore è munito di regolatore di velocità. Prevalenza proporzionale velocità 1 Queste impostazioni sono adeguate per la maggior parte di soluzioni impiantistiche. Il circolatore è equipaggiato con un’ e lettronica di comando che Prevalenza proporzionale velocità...
  • Page 9 Prevalenza disponibile all’impianto zona 1 circuito zona diretta. Velocità costante. 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 Prevalenza costante. 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 Prevalenza proporzionale. 1000 1200 1400 1600 1800 2000 2200...
  • Page 10 Prevalenza disponibile all’impianto zona 2 circuito zona diretta. Velocità costante. 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 Prevalenza costante. 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 Prevalenza proporzionale. 1000 1200 1400 1600 1800 2000 2200...
  • Page 11 Prevalenza disponibile all’impianto zona 2 circuito zona miscelata. Velocità costante. 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 Prevalenza costante. 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 Prevalenza proporzionale. 1000 1200 1400 1600 1800 2000 2200...
  • Page 12: Componenti Principali

    1.11 COMPONENTI PRINCIPALI. 2 zone dirette Legenda: 1 - Scatola allacciamento elettrico 2 - Valvola unidirezionale “Europa” zona 1 3 - Valvola unidirezionale “Europa” zona 2 4 - Raccordo di scarico 5 - Collettore idraulico 6 - Circolatore zona 1 7 - Circolatore zona 2 RZ1 - Ritorno zona 1 diretta RZ2 - Ritorno zona 2 diretta...
  • Page 13: Istruzioni Di Uso Emanutenzione

    ISTRUZIONI DI USO E 2.2 AVVERTENZE PER L’UTENTE. Questo dispositivo non necessita di nessuna regolazione o con- MANUTENZIONE trollo da parte dell’utente, è pertanto vietato aprire il coperchio frontale del dispositivo. 2.1 AVVERTENZE GENERALI. L’unica operazione che l’utente è tenuto a compiere è di controllare Allorché...
  • Page 14: Controllo Emanutenzione

    CONTROLLO E MANUTENZIONE - (Solo per 1 zona diretta e 1 zona miscelata) impostare una - verificare che l’impianto di riscaldamento / raffrescamento sia pieno d’acqua, controllando che la lancetta del manometro in- richiesta di calore nella zone miscelata con temperatura di set dichi una pressione di 1÷1,2 bar;...
  • Page 15 1 zona diretta e 1 zona miscelata E7-2 64-2 X102 64-2 B3-2 63-2 85-2 M31-2 X105 83-2 82-2 84-2 81-2 81-2 M10-2 83-2 82-2 84-2 85-2 82-1 82-1 M10-1 81-1 81-1 Legenda: B3-2 - Sonda mandata zona 2 1 - Pannello supervisore BK - Nero E7-2 - Termostato sicurezza bassa 2 - Scatola allacciamento...
  • Page 16 Schema idraulico esempio di collegamento (2 zone dirette). RZ1 RZ2 Legenda: 1 - Alimentazione 230 Vac 50 Hz 2 - Generatore 3 - Scatola allacciamenti 4 - Zona 2 diretta 5 - Zona 1 diretta ST.007963/000 Kit 2 Zone Solo Riscaldamento...
  • Page 17 Schema idraulico esempio di collegamento (1 zona diretta e 1 zona miscelata). RZ1 RZ2 Legenda: 1 - Alimentazione 230 Vac 50 Hz 2 - Generatore 3 - Scatola allacciamenti 4 - Zona 2 miscelata 5 - Zona 1 diretta ST.007963/000 Kit 2 Zone Solo Riscaldamento...
  • Page 18: Dati Tecnici

    DATI TECNICI. 4.1 TABELLA DATI TECNICI. 1 zona diretta e 1 zona 2 zone dirette miscelata Pressione massima nominale Temperatura massima d’ e sercizio °C Intervento Termostato di sicurezza Bassa Temperatura °C Contenuto d’acqua del dispositivo Peso dispositivo vuoto 19,8 20,9 Peso dispositivo pieno 23,1...
  • Page 19 Dear Client, Our compliments for having chosen a top-quality Immergas product, able to assure well-being and safety for a long period of time. As an Immergas cus- tomer you can also count on a qualified after-sales service, prepared and updated to guarantee constant efficiency of your products.
  • Page 20 INDEX. Installing the device ............. 21 Description of the device............. 21 Installation recommendations..........21 Main dimensions..............22 Hydraulic connection............23 Electrical connection............23 Installation diagrams............24 Commissioning the device..........24 Sizing the systems..............24 Kits available on request.
  • Page 21 1.2 INSTALLATION RECOMMENDATIONS. and kit must be inside the clearance of the device itself, first position The place of installation of the appliance and relative Immergas ac- the kit and then the system input and output pipes and the electric cessories must have suitable features (technical and structural), such cable ducts.
  • Page 22 1.3 MAIN DIMENSIONS. Key: RG - Generator return (G 1”) MG - Generator flow (G 1”) V - Electrical connection X - Holes for wall-mounted fastening Height Width Depth (mm) (mm) (mm) ST.007963/000 2 Zones Kit Heating Only...
  • Page 23 CONNECTIONS KIT 2 DIRECT ZONES Direct zone 1 re- Direct zone 2 re- Direct zone 2 flow Direct zone 1 flow turn system (G 1”) turn system (G 1”) system (G 1”) system (G 1”) CONNECTIONS KIT 1 DIRECT ZONE AND 1 MIXED ZONE Direct zone 1 re- Mixed zone 2 re- Mixed zone 2 flow...
  • Page 24 Check the complete list of kits available and which can indicates approx. 1.2 bar. be combined with the product, consult the Immergas website, the Immergas Price List or the technical- N.B.: during these operations activate the system vent function of commercial documentation (catalogues and data the hydronic unit (see relative instruction booklet).
  • Page 25 1.10 CIRCULATION PUMP. Pump LED Description The pump is equipped with a speed regulator. Proportional head speed 1 These settings are suitable for most systems. In fact, the pump is equipped with electronic control to set ad- vanced functions. For proper operation one must select the most Proportional head speed 2 suitable type of operation for the system and select a speed in the available range, with a focus on energy savings.
  • Page 26 Head available to the direct zone circuit zone 1. Constant speed. 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 Constant head. 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 Proportional head. 1000 1200 1400 1600 1800 2000...
  • Page 27 Head available to the direct zone circuit zone 2. Constant speed. 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 Constant head. 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 Proportional head. 1000 1200 1400 1600 1800 2000...
  • Page 28 Head available to the mixed zone circuit zone 2. Constant speed. 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 Constant head. 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 Proportional head. 1000 1200 1400 1600 1800 2000...
  • Page 29 1.11 MAIN COMPONENTS. 2 direct zones Key: 1 - Connection box 2 - Zone 1 “Europe” one-way valve 3 - Zone 2 “Europe” one-way valve 4 - Drain fitting 5 - Hydraulic manifold 6 - Zone 1 pump 7 - Zone 2 circulator RZ1 - Direct zone 1 return RZ2 - Direct zone 2 return MZ2 - Direct zone 2 flow...
  • Page 30 USE AND MAINTENANCE 2.2 WARNINGS FOR THE USER. This device does not require any regulation or control by the user; INSTRUCTIONS the opening of the device front lid is therefore prohibited. The only operation that the user must perform is to periodically 2.1 GENERAL WARNINGS.
  • Page 31 CHECKS AND MAINTENANCE - make sure the heating/cooling system is filled with water and - (1 direct zone and 1 mixed zone only) set a heat request in the that the manometer indicates a pressure of 1÷1.2 bar; mixed zone with a delivery set temperature greater than 60°C and check both the correct opening and closing of the mixing - make sure that the air valve cap (if present) is open and that the valve and the intervention of the safety thermostat (if present).
  • Page 32 1 direct zone and 1 mixed zone E7-2 64-2 X102 64-2 B3-2 63-2 85-2 M31-2 X105 83-2 82-2 84-2 81-2 81-2 M10-2 83-2 82-2 84-2 85-2 82-1 82-1 M10-1 81-1 81-1 Key: B3-2 - Zone 2 flow probe 1 - Supervisor panel BK - Black E7-2 - Zone 2 safety thermostat 2 - Connection box...
  • Page 33 Connection example of hydraulic diagram (2 direct zones). RZ1 RZ2 Key: 1 - 230 Vac - 50Hz Power supply 2 - Generator 3 - Connection box 4 - Direct zone 2 5 - Direct zone 1 ST.007963/000 2 Zones Kit Heating Only...
  • Page 34 Connection example of hydraulic diagram (1 direct zone and 1 mixed zone). RZ1 RZ2 Key: 1 - 230 Vac - 50Hz Power supply 2 - Generator 3 - Connection box 4 - Mixed zone 2 5 - Direct zone 1 ST.007963/000 2 Zones Kit Heating Only...
  • Page 35 TECHNICAL DATA. 4.1 TECHNICAL DATA TABLE. 1 direct zone and 1 mixed 2 direct zones zone Maximum nominal pressure Maximum operating temperature °C Low temperature safety thermostat intervention °C Water content in device Empty device weight 19.8 20.9 Full device weight 23.1 Electrical connection V/Hz...
  • Page 36 Immergas S.p.A. 42041 Brescello (RE) - Italy Tel. 0522.689011 immergas.com Per richiedere ulteriori approfondimenti specifici, i Professionisti del settore possono anche avvalersi dell’indirizzo e-mail: consulenza@immergas.com To request further specific details, sector Professionals can also use the following e-mail address: consulenza@immergas.com Nel corso della vita utile dei prodotti, le prestazioni sono influenza- te da fattori esterni, come ad es.

This manual is also suitable for:

3.035334

Table of Contents