  • Page 1 DF Series Compressed Air Filters Models: DF20-(grade) through DF780-(grade) FORM NO.: 3163133 REVISION: 01/2024 INSTRUCTION MANUAL Read and understand this manual deltechair.com prior to operating or servicing this product.
  • Page 2: Table Of Contents

    • The type of area - forced exhaust system used (i.e., high or low level) would be dependent on the gas involved. • Each application (other than for air or inert gas) must be reviewed to minimize fire or explosion hazard. 02 | DF Series Instruction Manual...
  • Page 3: Model Number Configuration

    1 micron coalescer none Separator/Filter Mechanical separator and 3 micron coalescer none Mechanical Separator Impaction type separator none Dry Desiccant Afterfilter 1 micron after-filter for desiccant dryers none Oil Vapor Removal Filter Activated carbon adsorber Green DF Series Instruction Manual | 03...
  • Page 4: Installation

    • Downstream of an Activated Carbon or Desiccant Tower Afterfilter to Grade A & Grade B for true oil Removes vapors No liquid should be 0.003 0.01 free applications only present vapor 04 | DF Series Instruction Manual...
  • Page 5 Remove black plastic top cap, apply generous amount of lubricant to o-ring, Wall Mounting install o-ring in groove, and insert connectors. Bracket Screw connectors to head using socket head cap screws. Top Cap Figure 1.1 Figure 1.3 DF Series Instruction Manual | 05...
  • Page 6 Isolation valves and by-pass piping - For ease of service, isolation and by-pass valves are desirable. In critical applications, two filters installed in parallel may be necessary to avoid interruption of air supply. 06 | DF Series Instruction Manual...
  • Page 7: Operation

    Open (To Right) Flow, pressure and temperatures outside design conditions. Presence of gaseous impurities which cannot be adsorbed. Methane, carbon monoxide, carbon dioxide and various inorganic gases cannot be removed by an activated carbon filter. DF Series Instruction Manual | 07...
  • Page 8: Maintenance

    0.30 0.39 0.48 0.65 0.82 1.00 1.17 1.43 1.87 2.31 2.74 drained and that prefiltration is required. Grade Z (activated carbon filters) Adsorption capacity - 1000 hours at rated capacity. Element life is exhausted when odor can be detected downstream of the filter. 08 | DF Series Instruction Manual...
  • Page 9 4) Slide new filter sleeve over separator core and replace bottom cap and hand tighten bolt. 5) Make certain o-ring inside top of element is in place and push element onto filter head. DF Series Instruction Manual | 09...
  • Page 10: Dimensions And Weights

    4.0 Dimensions and Weights 4.0 Dimensions and Weights 010 | DF Series Instruction Manual...
  • Page 11: Warranty

    The manufacturer does not warrant any product, part, material, component, or accessory manufactured by others and sold or supplied in connection with the sale of manufacturer’s products. AUTHORIZATION FROM THE SERVICE DEPARTMENT IS NECESSARY BEFORE MATERIAL IS RETURNED TO THE FACTORY OR IN-WARRANTY REPAIRS ARE MADE. SERVICE DEPARTMENT: (724) 746-1100 DF Series Instruction Manual | 011...
  • Page 12 Air Filters Models: DF20-(grade) through DF780-(grade) Deltech Headquarters 4647 SW 40th Avenue Ocala, Florida 34474-5788 U.S.A. Tel.: (724) 745-1555 Email: CustomerSupport.oca@its-ats.com deltechair.com Improvements and research are continuous at Deltech. Specifications may change without notice. ISSUED: 01/2024 Form No.: 3163133 Revision: 01/2024...